Implementing a Clone Remote Operation

WARNING

The modem begins a transfer of its own program to the remote modem. This process takes the communication link out-of-service for several minutes depending on the data rate of the link. If the Clone Remote process is started and then interrupted, the remote modem is left in a partially programmed state in which its functional capabilities are limited to those required to initiate and complete another download attempt.

Warning:Download

Abort_Download

F1 F2 F3

At this point, if you do not want to continue this process, abort the transfer by selecting any function key. This returns the modem to the DwnLoadSoftware menu. However, to continue with

the transfer, press the key to display the Reprogram_Remote selection.

Warning:Download

Reprogram_Remote

F1 F2 F3

Press any function key to begin the transfer.

RemClone Status

Establish Remote

F1 F2 F3

The local modem’s LCD displays Establish Remote, indicating the modem is attempting to establish a Remote Cloning Download session with the remote modem.

If unsuccessful, the modem remains in the Download Transfer mode. The LCD’s top line displays RemClone Failed and the bottom line displays one of the following messages:

Incompat Modulat

The modems are connected, but are using a modulation scheme other

 

than V.33, V.32terbo, V.32bis, V.32, V.29, or TMp.

No Response

The remote modem is not a 3900 Series modem or the connection

 

between the two modems is poor.