COMSPHERE 3900 Series Modems

To correct the invalid VF threshold, press the key to return to the VF Threshold Edit/Save/Reset screen.

VF Thresholds

Edit

Save

Reset

F1

F2

F3

Select Reset to restore the original default values into memory.

Repeat the Edit and Save procedure until the VF threshold(s) is valid and the Save completes successfully (Save Completed).

To exit this function and remain in the Control branch, press the key. To exit and return to

the Top-Level menu, press the key.

Table 7-1

Valid Ranges for VF Thresholds

VF Thresholds

Valid Ranges

Default Values

 

 

 

Receive Signal Level High

0 dBm to –15 dBm

Above –9 dBm

 

 

 

Receive Signal Level Low

–16 dBm to –50 dBm

Below –23 dBm

 

 

 

Signal to Noise Ratio

5 dB to 40 dB

Below 23 dB

 

 

 

Non-Linear Distortion

15 dB to 50 dB

Below 30 dB

 

 

 

Retrains

1 to 256 trains

15 trains per 15 minutes

 

 

 

 

Signal Quality

Excellent

(lowest)

Good

 

Good

 

 

 

Fair

 

 

 

Poor

 

 

 

No Signal

(highest)

 

 

 

 

Near Echo

0 — 38 dBm

Above –20 dBm

 

 

 

Far Echo

0 — 38 dBm

Above –20 dBm

 

 

 

 

7-16

September 1998

3910-A2-GN32-40

Page 136
Image 136
Digicom 3911, 3910 operation manual Valid Ranges for VF Thresholds Default Values