COMSPHERE 3900 Series Modems

Table 14-3

(2 of 13)

391x Series S-Registers

S-Register

Description

DCP LCD

Command

 

 

Sequence

 

 

 

S5

Backspace Character. Register determines ASCII value used as the

Configure\Edit\

 

backspace (Backspace key). This character moves the cursor to the

DTE Dialer

 

left and erases the previous character.

 

 

Enter a value from 0–127. The factory setting is 8 (backspace key).

 

 

 

 

S6

Blind Dial Pause1. Register determines how long (in seconds) the

Configure\Edit\

 

modem waits after going off-hook before dialing a telephone number if

Line Dialer

 

using result code X0, X1, or X3.

 

 

Enter a value from 2–255 seconds. The factory setting is 2.

 

 

 

 

S7

No Answer Time-out1. Register determines how long (in seconds) an

Configure\Edit\

 

originating modem waits before abandoning a call when no answer

Line Dialer

 

tone is received.

 

 

Enter a value from 1–255 seconds. The factory setting is 45.

 

 

 

 

S8

“,” Pause Time for the Dial Modifier. Register determines how long (in

Configure\Edit\

 

seconds) the modem pauses when it encounters a comma (,) in the

Line Dialer

 

Dial command string.

 

 

Enter a value from 0–255 seconds. The factory setting is 2.

 

 

 

 

S10

No Carrier Disconnect1. Register determines how long (in tenths of

Configure\Edit\

 

seconds) the modem allows the carrier signal to be OFF before

Line Dialer

 

disconnecting the call.

 

 

Enter a value from 0–254 in 0.1 second increments. A value of 255

 

 

disables this register. The factory setting is 20 (2 seconds).

 

 

 

 

S12

Escape Guard Time. Register sets the value (in 20-millisecond

Configure\Edit\

 

increments) for the required pause before and after the escape

DTE Dialer

 

sequence is issued. The guard time prevents the modem from

 

 

interpreting data as the escape sequence characters.

 

 

Enter a value from 0–255 in 20-millisecond increments. The factory

 

 

setting of 50 equals 1000 milliseconds or one second.

 

 

 

 

S18

Test Time-out. Register sets the duration (in seconds) for the modem

Configure\Edit\

 

tests. This automatically cancels any test in progress after the time of

Tests

 

this register expires. Any test can be manually canceled by issuing the

 

 

escape sequence (+++) followed by the &T0 command.

 

 

Enter a value from 0–255 seconds. A value of 0 disables this register.

 

 

The factory setting is Disable (0).

 

 

 

 

S26

RTS-to-CTS Delay. Register sets the length of time (in 10-millisecond

Configure\Edit\

 

increments) the modem waits after receiving RTS before issuing CTS

DTE Interface

 

to the DTE.

 

 

Enter a value from 0–255. The factory setting is 0.

 

 

 

 

1 The range of allowable values may be restricted in some countries.

14-16

September 1998

3910-A2-GN32-40

Page 206
Image 206
Digicom 3911, 3910 operation manual 14-16