COMSPHERE 3900 Series Modems

Test

The Test configuration options determine specifics, such as the duration of a test, for the various diagnostic tests available to the modem.

Table 5-7 shows each Test configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

Table 5-7

(1 of 2)

Test Configuration Options

DTE RL (CT140): Disable

Nxt Disable Enable

DTE Remote Loopback. Controls the use of Pin 21 of the EIA-232-D/ITU-T V.24 interface by the DTE to initiate a remote loopback. An Abort command or test timeout ends this test.

This configuration option is not available if the LeasedLine Rate is configured for TMp.

HEnable

The DTE forces the modem into remote loopback when the signal on Pin 21 (ITU-T 140) is turned ON. Remote Loop ends when the signal is dropped.

HDisable

The DTE does not initiate remote loopback in response to the signal on Pin 21.

The AT command is S-Register S51=n, where n is 0 for Disable and 1 for Enable.

DTE LL (CT141): Disable

Nxt Disable Enable

DTE Local Loopback. Controls the use of Pin 18 of the EIA-232-D/ITU-T V.24 interface by the DTE to initiate a local loopback. An Abort command or test timeout ends this test.

HEnable

The DTE forces the modem into local loopback when the signal on Pin 18 (ITU-T 141) is turned ON. Local loopback ends when the signal is dropped.

HDisable

The DTE will not initiate local loopback in response to the signal on Pin 18.

The AT command is S-Register S52=n, where n is 0 for Disable and 1 for Enable.

5-46

September 1998

3910-A2-GN32-40

Page 108
Image 108
Digicom 3911, 3910 operation manual Test Configuration Options