Image 207

AT Command Set and S-Registers

Table 14-3

(3 of 13)

391x Series S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S40

Auto Make Busy. Register determines if the modem goes off-hook

Configure\Edit\

 

under certain conditions. This register should only be enabled when

Line Dialer

 

the modem is located behind a user’s Private Branch Exchange

 

 

(PBX). This register is only valid for Model 3911 modems.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

The factory setting is Disable.

 

 

 

 

S41

Dial-Line Rate. Register determines the modem’s data rate and

Configure\Edit\

 

modulation scheme for operation on dial lines.

Dial Line

 

Register has the following values:

 

 

1

= 14,400 (V.32bis)

 

 

2

= 12,000(V.32bis)

 

 

3

= 9600 (V.32bis)

 

 

4

= 7200 (V.32bis)

 

 

5

= 4800 (V.32bis)

 

 

6

= 2400 (V.22bis)

 

 

7

= 1200 (V.22)

 

 

8

= 1200 (212A)

 

 

10

= 0-300 (V.21)

 

 

11

= 0-300 (103J)

 

 

12

= 1200/75 (V.23)

 

 

13

= 75/1200 (V.23)

 

 

18

= 600/75 (V.23)

 

 

19

= 75/600 (V.23)

 

 

20

= 19,200 (V.32terbo)

 

 

21

= 16,800 (V.32terbo)

 

 

The factory setting is 19200 (V.32terbo).

 

 

 

 

S43

V.32bis Train. Register controls the modem’s train time for

Configure\Edit\

 

V.32bis/V.32 mode.

Dial Line

 

Register has the following values:

 

 

0

= Long

 

 

1

= Short

 

 

The factory setting is Long.

 

 

 

 

 