Digicom 3910, 3911 operation manual Pattern, Test LocDigitalLoop, TestDigitl Loop Started

Models: 3910 3911

1 280
Download 280 pages 20.93 Kb
Page 143
Image 143

Test Branch

Test:

Loc_Digital_Loop

F1 F2 F3

Press the key until Loc_Digital_Loop appears. Press any function key to start this test.

Test:Digitl Loop

Started

F1 F2 F3

The message Started appears on the LCD and the Test LED lights. If Invalid Command appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the display. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to Test in Chapter 5, DCP Configuration.

To exit this function and remain in the Test branch, press the key. To exit and return to the

Top-Level menu, press the key.

Pattern

Pattern can transmit and receive a 511 bit error rate test pattern. It can also be used with a currently running local analog loopback or a remote digital loopback to simulate data passing through the modem. You will need to start the local analog or remote digital loopback test before you start the pattern test. For this test to operate properly, the modems must be online and in Synchronous or Asynchronous Direct mode (Figures 8-4 through 8-6).

Figure 8-4. Pattern Test and Local Analog Loopback Test

3910-A2-GN32-40

September 1998

8-7

Page 143
Image 143
Digicom 3910, 3911 operation manual Pattern, Test LocDigitalLoop, TestDigitl Loop Started