Rinnai EX08C (RHFE-202FTA) installation manual Parts List, Rinnai Corporation EX08C, EX11C Manual

Page 39
Manual background

Parts List

No

Name

Nom

Part Number (Numéro

EX08C

EX11C

 

 

 

de la Pièce)

 

 

 

 

 

 

 

 

111

Burner Box

ensemble de boîtier de brûleur

206000030

1

1

112

Burner Assy

ensemble de brûleur

B3A2-4

2

2

113

Burner Box Supporter Assy

support de boîtier de brûleur

556F-225-2

1

1

114

Burner Box Packing

garniture de boîtier de brûleur

556F-211

1

1

115

Damper

amortisseur

308F-209-13

1

 

115

Damper

amortisseur

308F-209-7

1

 

115

Damper

amortisseur

206000031

 

1

116

Secondary Air Damper

amortisseur secondaire

308F-218-1

1

 

116

Secondary Air Damper

amortisseur secondaire

308F-218-3

1

1

116

Secondary Air Damper

amortisseur secondaire

556F-208-3

 

1

116

Secondary Air Damper

amortisseur secondaire

206000032

 

1

117

Electrode Mounting Plate

plaque de montage d’électrode

554F-114

1

1

118

Electrode

électrode

205000028

1

1

119

Electrode Packing

garniture d’électrode

554F-147

1

1

120

Injector

injecteur

AU129-210X02-0.9

2

 

120

Injector

injecteur

AU129-211X01-1.0

 

2

120

Injector

injecteur

206000034

 

2

120

Injector

injecteur

206000033

2

 

121

Manifold B

collecteur B

308F-202-2

1

1

122

Manifold Packing

garniture de collecteur

556F-203-2

1

1

123

Burner Box Fitting Plate Assy

jeu pour plaque de fixation de boîtier de brûleur

206000025

1

1

124

Fitting Plate Packing

garniture de plaque de fixation

209000078

1

1

125

Warm Air Seal Panel

panneau de fermeture d’air chaud

556F-305

1

1

126

Heat Exchanger Packing

enveloppe d’échangeur thermique

554F-421-2

1

1

127

Gas Control Assy

ensemble de commande de gaz

206000035

1

1

128

Test Port Screw

vis de liaison

AU39-965

2

2

129

Interconnection Assy

ensemble d’interconnexion

206000036

1

1

130

O Ring

joint torique

M10B-1-10

2

2

131

Tube C (Black)

tube C (noir)

1004F-2052-3

1

1

132

Tube A (Clear)

tube A (espace libre)

1004F-2052-1

1

1

133

Connecting Tube Retainer

fixation de tube de connexion

209000079

1

1

134

Combustion Fan Motor Assy

anneau

208000030

1

1

135

Combustion Fan Motor Bracket

support anneau

209000080

1

1

136

Cushion Rubber

coussinet caoutchouc

308F-8273

7

7

138

Front Panel Bracket

support panneau frontal

209000081

1

1

139

Front Panel Packing

garniture d'panneau frontal

209000082

1

1

140

Lock Bracket

support verrou

209000083

2

2

141

Air Inlet C

arrivée d’air C

208000032

 

1

141

Air Inlet B

arrivée d’air B

208000031

1

 

142

Air Inlet Packing

garniture d’arrivée d’air

209000084

1

1

143

Combustion Chamber Connec-

 

 

1

1

tion

fixation de chambre de combustion

208000033

144

Connecting Tube Fixer

fixation de tube de connexion

208000018

1

1

145

Tube E

tube E

208000034

1

1

146

Clip J

Clip J

209000085

1

1

147

Air Inlet A

arrivée d’air A

553F-340-1

1

1

148

Air Inlet Packing

garniture d’arrivée d’air

RHF300F-79

1

1

 

 

Rinnai Corporation EX08C, EX11C Manual

 

39

Image 39
Contents Energysaver Owner’s Operation and Installation Manual for theEX08C RHFE-202FTA EX11C RHFE-265FTAInstallation Instructions Table of ContentsConsumer Safety Information SpecificationsDANGER Consumer Safety InformationSafety Definitions Safety Behaviors and PracticesSpecifications Safety FeaturesAppliance Specifications EX08C FeaturesFlue Manifolds Appliance SpecificationsGetting to Know your New Heating Appliance Operating InstructionsSensible Temperature Control Control PanelON / OFF Child LockSetting the timers Setting the ClockSetting and Operating the Timers Operating the Heater ManuallyOverride Function Economy Energy Saving ModeEconomy Mode Information Adding Water to the Humidifier Adjusting Air Flow DirectionSet back Humidifier and Air Flow DirectionSnow Accumulation Care and MaintenanceMaintenance Care of ExteriorDuring Combustion Before Making a Service CallWhen the unit is turned off At IgnitionREMEDY Fault CodesFAULT CODE DISPLAYEDUnusualcombustion TroubleshootingRestart Function Burnerdoesn’t igniteGeneral Instructions Installation InstructionsClearances to Combustibles Gas ConnectionDimensions Drilling Flue HoleFlue Hole Flue Terminal Clearances D E B LH I M K Description Canadian InstallationsUS Installations Flue Terminal Clearances“A” Vent Kit, FOT-151 Installation PartsFor weatherboard installations Flue Manifold1Spare rubber sealFlue Manifold Installation 4. Install the Terminal Terminal seal Flue Manifold InstallationExtension Kit Installation EX11C only Extension Kit Installation EX11C only Installing the Exhaust LineConnecting the Air Intake Hose ClampsDescription Extension Kits and PartsExtension Kit Installation EX11C only ItemConnecting the Appliance and slip the securing clip over the sleeve asshown EX08C Adjust Gas Pressure SettingsNatural Gas Propane GasVisual Inspection of Flame Final AssemblyNormal Operating Sequence Adjust Gas Pressure SettingsTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions OPERATING INSTRUCTIONSRinnai Corporation EX08C, EX11C Manual Cut-AwayDiagramwith the appliance must be replaced Wiring DiagramIf any of the original wire as supplied AWG wire or its equivalentLadder Diagram Parts List For replacement parts call Rinnai atRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListFor converting to LPG Parts ListModel For converting to NGGas Direct Vent Wall Furnace Warranty InformationLimited Warranty Consumer SupportLimitation on warranties Limited Warranty - continuedHow do I get service? What is not covered?Energysaver Manuel d’installation et d’utilisation pourEX08C RHFE-202FTA EX11C RHFE-265FTASécurité du consommateur Table des matièresInstructions d’installation Service à la clientèleDANGER Sécurité du consommateurDéfinitions de sécurité Comportements et pratiques de sécuritéEX08C SpécificationsDispositifs de sécurité Spécifications de l’appareilEX08C CaractéristiquesCollecteur de fumée Spécifications de l’appareilConnaissance du nouveau chauffage Instructions d’utilisationContrôle de température Panneau de commandesMarche / Arrêt Verrouillage pour les enfantsParamétrage des minuteries Mise à l’heureUtilisation manuelle du chauffage Réglage et utilisation des minuteriesFonction de surpassement Économie Mode de conservation d’énergieInformations sur le mode déconomie dénergie Réglage de la direction du flux dair Programmation de température minimaleHumidificateur et direction du flux d’air Ajout deau dans lhumidificateurAccumulation de neige Soins et entretienEntretien Soins pour l’extérieurAvant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints REMÈDE Codes de défautsCODE AFFICHÉ DÉFAUTDépannage Fonction de redémarrageInstructions générales Instructions d’installationzéro - voir la notification zéro 2 in 50 mm Connexion de gazDégagement par rapport aux combustibles Manuel de gaz robinet darrêtDégagements en sortie de cheminée Description Dégagements en sortie de cheminée SuiteInstallations Canada Installations USAPercez le trou de conduite Dimensions3 1/8 80 mm Ces pinces devraient être situés ici Pièces d’installationOwner’s Manual “A”“A”VentVentKit,Kit,FOTFOT-151-151Installation du collecteur de fumée 3 visRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée SuiteRinnai Corporation EX08C, EX11C Manual Installation du kit d’extension EX11C seulementConnexion de la conduite d’évacuation Installation de la conduite d’évacuationDégagements AttachesDescription Kits et pièces d’extensionInstallation du kit d’extension EX11C seulement ItemBranchement de l’appareil EX08C Ajustage et Reglage de la Presion de GasGaz Naturel Gaz PropaneAjustage et Reglage de la Presion de Gas La Séquence normale dOpérationLInspection visuelle de Flamme Assemblée finaleInstructions de mise en œuvre INSTRUCTIONS DE DÉMARRAGECOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe calibre 18 AWG ou équivalent Schéma de câblageSi des fils d’origine livrés avec l’appareil ont besoin d’être remplacés, choisissez un fil deDiagramme logique Qu’est-cequi est couvert? Service à la clientèleInformations de garantie Garantie limitéeQu’est-cequi n’est pas couvert? Garantie limitée SuiteComment obtenir le service sous garantie? Rinnai Corporation EX08C, EX11C ManualRinnai Corporation EX08C, EX11C Manual NotesRinnai Corporation EX08C, EX11C Manual NotesRHF265-1091X0100Printed in Japan