Installation Instructions

Installation Instructions

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

A qualified service technician should install the appliance and inspect it before use.

If you move, check the gas type in your new area. The local gas authority will be able to advise on local regulations.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or the standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

Appliance input ratings are based on sea level operation and need not be changed for operation up to 2000 ft (610 m) elevation. For operation at elevations above 2000 ft (610 m), follow the procedure in the section, Adjust Gas Pressure Settings.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

If the flooring is carpet, tile, or other combustible material other than wood, then the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

Rinnai suggests that a dedicated electrical circuit with a 120V AC, 60 Hz, 10 amp power source be used.

This appliance discharges a large volume of warm air next to the floor. Any particles in the air such as cigarette smoke could cause discoloration in carpet. The warm air flow could discolor nylon carpets containing dyes or vinyl surfaces. To prevent discoloration of the floor covering a mat may be placed under the appliance which extends about 30 inches (750 mm) in front of it.

This appliance is not designed to built in.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. If a conversion of the unit is needed, conversions must be performed by a qualified service provider at the owner’s expense.

Follow the Adjust Gas Pressure Settings (page 27) and confirm that the correct code is used for your gas type and altitude.

This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

Two 1/8 in test plugs are provided for testing of manifold differential pressure. They are located on the modulating gas valve and on the burner manifold.

The appliance should be correctly sized for the space it is required to heat. It is recommended that an industry standard BTU Heat Loss Calculation be conducted to determine the proper sizing.

Follow the installations instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The flow of combustion and ventilation air shall not be obstructed.

Clearances to access the appliance during servicing are 2 inches (50 mm) from the sides, 40 inches (1 m) from the front, and 9 inches (225 mm) from the top.

Locate the heater where outdoor air does not affect the room air thermistor. Otherwise, the temperature control feature will be affected.

Rinnai Corporation EX08C, EX11C Manual

15

Image 15
Contents Energysaver Owner’s Operation and Installation Manual for theEX08C RHFE-202FTA EX11C RHFE-265FTAInstallation Instructions Table of ContentsConsumer Safety Information SpecificationsDANGER Consumer Safety InformationSafety Definitions Safety Behaviors and PracticesSpecifications Safety FeaturesAppliance Specifications EX08C FeaturesFlue Manifolds Appliance SpecificationsGetting to Know your New Heating Appliance Operating InstructionsSensible Temperature Control Control PanelON / OFF Child LockSetting the timers Setting the ClockSetting and Operating the Timers Operating the Heater ManuallyOverride Function Economy Energy Saving ModeEconomy Mode Information Adding Water to the Humidifier Adjusting Air Flow DirectionSet back Humidifier and Air Flow DirectionSnow Accumulation Care and MaintenanceMaintenance Care of ExteriorDuring Combustion Before Making a Service CallWhen the unit is turned off At IgnitionREMEDY Fault CodesFAULT CODE DISPLAYEDUnusualcombustion TroubleshootingRestart Function Burnerdoesn’t igniteGeneral Instructions Installation InstructionsClearances to Combustibles Gas ConnectionDimensions Drilling Flue HoleFlue Hole Flue Terminal Clearances D E B LH I M K Description Canadian InstallationsUS Installations Flue Terminal Clearances“A” Vent Kit, FOT-151 Installation PartsFor weatherboard installations Flue Manifold1Spare rubber sealFlue Manifold Installation 4. Install the Terminal Terminal seal Flue Manifold InstallationExtension Kit Installation EX11C only Extension Kit Installation EX11C only Installing the Exhaust LineConnecting the Air Intake Hose ClampsDescription Extension Kits and PartsExtension Kit Installation EX11C only ItemConnecting the Appliance and slip the securing clip over the sleeve asshown EX08C Adjust Gas Pressure SettingsNatural Gas Propane GasVisual Inspection of Flame Final AssemblyNormal Operating Sequence Adjust Gas Pressure SettingsTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions OPERATING INSTRUCTIONSRinnai Corporation EX08C, EX11C Manual Cut-AwayDiagramwith the appliance must be replaced Wiring DiagramIf any of the original wire as supplied AWG wire or its equivalentLadder Diagram Parts List For replacement parts call Rinnai atRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListFor converting to LPG Parts ListModel For converting to NGGas Direct Vent Wall Furnace Warranty InformationLimited Warranty Consumer SupportLimitation on warranties Limited Warranty - continuedHow do I get service? What is not covered?Energysaver Manuel d’installation et d’utilisation pourEX08C RHFE-202FTA EX11C RHFE-265FTASécurité du consommateur Table des matièresInstructions d’installation Service à la clientèleDANGER Sécurité du consommateurDéfinitions de sécurité Comportements et pratiques de sécuritéEX08C SpécificationsDispositifs de sécurité Spécifications de l’appareilEX08C CaractéristiquesCollecteur de fumée Spécifications de l’appareilConnaissance du nouveau chauffage Instructions d’utilisationContrôle de température Panneau de commandesMarche / Arrêt Verrouillage pour les enfantsParamétrage des minuteries Mise à l’heureUtilisation manuelle du chauffage Réglage et utilisation des minuteriesFonction de surpassement Économie Mode de conservation d’énergieInformations sur le mode déconomie dénergie Réglage de la direction du flux dair Programmation de température minimaleHumidificateur et direction du flux d’air Ajout deau dans lhumidificateurAccumulation de neige Soins et entretienEntretien Soins pour l’extérieurAvant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints REMÈDE Codes de défautsCODE AFFICHÉ DÉFAUTDépannage Fonction de redémarrageInstructions générales Instructions d’installationzéro - voir la notification zéro 2 in 50 mm Connexion de gazDégagement par rapport aux combustibles Manuel de gaz robinet darrêtDégagements en sortie de cheminée Description Dégagements en sortie de cheminée SuiteInstallations Canada Installations USAPercez le trou de conduite Dimensions3 1/8 80 mm Ces pinces devraient être situés ici Pièces d’installationOwner’s Manual “A”“A”VentVentKit,Kit,FOTFOT-151-151Installation du collecteur de fumée 3 visRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée SuiteRinnai Corporation EX08C, EX11C Manual Installation du kit d’extension EX11C seulementConnexion de la conduite d’évacuation Installation de la conduite d’évacuationDégagements AttachesDescription Kits et pièces d’extensionInstallation du kit d’extension EX11C seulement ItemBranchement de l’appareil EX08C Ajustage et Reglage de la Presion de GasGaz Naturel Gaz PropaneAjustage et Reglage de la Presion de Gas La Séquence normale dOpérationLInspection visuelle de Flamme Assemblée finaleInstructions de mise en œuvre INSTRUCTIONS DE DÉMARRAGECOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe calibre 18 AWG ou équivalent Schéma de câblageSi des fils d’origine livrés avec l’appareil ont besoin d’être remplacés, choisissez un fil deDiagramme logique Qu’est-cequi est couvert? Service à la clientèleInformations de garantie Garantie limitéeQu’est-cequi n’est pas couvert? Garantie limitée SuiteComment obtenir le service sous garantie? Rinnai Corporation EX08C, EX11C ManualRinnai Corporation EX08C, EX11C Manual NotesRinnai Corporation EX08C, EX11C Manual NotesRHF265-1091X0100Printed in Japan