Rinnai EX08C (RHFE-202FTA) Wiring Diagram, If any of the original wire as supplied

Page 31
Wiring Diagram

Wiring Diagram

 

 

 

 

 

If any of the original wire as supplied

 

 

 

 

 

with the appliance must be replaced,

 

 

 

 

 

 

 

 

 

 

it must be replaced with type 18

 

 

 

 

 

AWG wire or its equivalent.

 

 

 

 

 

 

 

 

MARK

PART NAME

MARK

 

PART NAME

 

 

 

 

 

 

 

 

 

MS

MAIN SWITCH

OH.TH

 

OVER HEAT THERMISTOR

 

 

 

 

 

 

 

 

 

R.TH

THERMISTOR

OHS1, 2

 

OVER HEAT SWITCH 1, 2

 

 

 

 

 

 

 

 

 

TF

THERMAL FUSE

FM

 

CONVECTION FAN MOTOR

 

 

 

 

 

 

 

 

 

F

FUSE

SP

 

SPARKER

 

 

 

 

 

 

 

 

 

ER

ELECTRODE

SV1, 2

 

MAIN SOLENOID VALVE 1, 2

 

 

 

 

 

 

 

 

 

POV

MODULATING SOLENOID

BL

 

COMBUSTION FAN MOTOR

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

TR

TRANSFORMER

PS

 

PRESSURE SENSOR

 

 

 

 

 

 

 

 

 

FR

FLAME ROD

 

 

 

 

 

 

 

 

 

 

 

 

Rinnai Corporation EX08C, EX11C Manual

CODE

COLOR

 

 

bk

black

 

 

bl

blue

 

 

gr

green

 

 

gr/y

green/yellow

 

 

r

red

 

 

w

white

 

 

y

yellow

 

 

gy

gray

 

 

or

orange

 

 

br

brown

 

 

31

Image 31
Contents Energysaver Owner’s Operation and Installation Manual for theEX08C RHFE-202FTA EX11C RHFE-265FTAInstallation Instructions Table of ContentsConsumer Safety Information SpecificationsDANGER Consumer Safety InformationSafety Definitions Safety Behaviors and PracticesSafety Features SpecificationsAppliance Specifications EX08C FeaturesFlue Manifolds Appliance SpecificationsGetting to Know your New Heating Appliance Operating InstructionsSensible Temperature Control Control PanelON / OFF Child LockSetting the timers Setting the ClockSetting and Operating the Timers Operating the Heater ManuallyEconomy Energy Saving Mode Override FunctionEconomy Mode Information Adding Water to the Humidifier Adjusting Air Flow DirectionSet back Humidifier and Air Flow DirectionSnow Accumulation Care and MaintenanceMaintenance Care of ExteriorDuring Combustion Before Making a Service CallWhen the unit is turned off At IgnitionREMEDY Fault CodesFAULT CODE DISPLAYEDUnusualcombustion TroubleshootingRestart Function Burnerdoesn’t igniteGeneral Instructions Installation InstructionsClearances to Combustibles Gas ConnectionDrilling Flue Hole DimensionsFlue Hole D E B L Flue Terminal ClearancesH I M K Description Canadian InstallationsUS Installations Flue Terminal Clearances“A” Vent Kit, FOT-151 Installation PartsFor weatherboard installations Flue Manifold1Spare rubber sealFlue Manifold Installation 4. Install the Terminal Terminal seal Flue Manifold InstallationExtension Kit Installation EX11C only Extension Kit Installation EX11C only Installing the Exhaust LineConnecting the Air Intake Hose ClampsDescription Extension Kits and PartsExtension Kit Installation EX11C only Itemand slip the securing clip over the sleeve as Connecting the Applianceshown EX08C Adjust Gas Pressure SettingsNatural Gas Propane GasVisual Inspection of Flame Final AssemblyNormal Operating Sequence Adjust Gas Pressure SettingsTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions OPERATING INSTRUCTIONSRinnai Corporation EX08C, EX11C Manual Cut-AwayDiagramwith the appliance must be replaced Wiring DiagramIf any of the original wire as supplied AWG wire or its equivalentLadder Diagram For replacement parts call Rinnai at Parts ListRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListFor converting to LPG Parts ListModel For converting to NGGas Direct Vent Wall Furnace Warranty InformationLimited Warranty Consumer SupportLimitation on warranties Limited Warranty - continuedHow do I get service? What is not covered?Energysaver Manuel d’installation et d’utilisation pourEX08C RHFE-202FTA EX11C RHFE-265FTASécurité du consommateur Table des matièresInstructions d’installation Service à la clientèleDANGER Sécurité du consommateurDéfinitions de sécurité Comportements et pratiques de sécuritéEX08C SpécificationsDispositifs de sécurité Spécifications de l’appareilEX08C CaractéristiquesCollecteur de fumée Spécifications de l’appareilConnaissance du nouveau chauffage Instructions d’utilisationContrôle de température Panneau de commandesMarche / Arrêt Verrouillage pour les enfantsParamétrage des minuteries Mise à l’heureUtilisation manuelle du chauffage Réglage et utilisation des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementInformations sur le mode déconomie dénergie Réglage de la direction du flux dair Programmation de température minimaleHumidificateur et direction du flux d’air Ajout deau dans lhumidificateurAccumulation de neige Soins et entretienEntretien Soins pour l’extérieurAtÀ l’allumageIgnition Avant d’appeler pour de l’aideAutresOther pointsPoints REMÈDE Codes de défautsCODE AFFICHÉ DÉFAUTDépannage Fonction de redémarrageInstructions générales Instructions d’installationzéro - voir la notification zéro 2 in 50 mm Connexion de gazDégagement par rapport aux combustibles Manuel de gaz robinet darrêtDégagements en sortie de cheminée Description Dégagements en sortie de cheminée SuiteInstallations Canada Installations USADimensions Percez le trou de conduite3 1/8 80 mm Ces pinces devraient être situés ici Pièces d’installationOwner’s Manual “A”“A”VentVentKit,Kit,FOTFOT-151-1513 vis Installation du collecteur de fuméeRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée SuiteRinnai Corporation EX08C, EX11C Manual Installation du kit d’extension EX11C seulementConnexion de la conduite d’évacuation Installation de la conduite d’évacuationDégagements AttachesDescription Kits et pièces d’extensionInstallation du kit d’extension EX11C seulement ItemBranchement de l’appareil EX08C Ajustage et Reglage de la Presion de GasGaz Naturel Gaz PropaneAjustage et Reglage de la Presion de Gas La Séquence normale dOpérationLInspection visuelle de Flamme Assemblée finaleINSTRUCTIONS DE DÉMARRAGE Instructions de mise en œuvreCOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe calibre 18 AWG ou équivalent Schéma de câblageSi des fils d’origine livrés avec l’appareil ont besoin d’être remplacés, choisissez un fil deDiagramme logique Qu’est-cequi est couvert? Service à la clientèleInformations de garantie Garantie limitéeQu’est-cequi n’est pas couvert? Garantie limitée SuiteComment obtenir le service sous garantie? Rinnai Corporation EX08C, EX11C ManualRinnai Corporation EX08C, EX11C Manual NotesRinnai Corporation EX08C, EX11C Manual NotesRHF265-1091X0100Printed in Japan