Rinnai EX11C (RHFE-265FTA), EX08C (RHFE-202FTA) Set back, Humidifier and Air Flow Direction

Page 10
Set back

Set back

This function allows a minimum room temperature to be pre-set, between 38ºF and 78ºF (in 2ºF increments). This temperature should be set below the room temperature setting. The default setting is 60ºF. Once the Set back function is selected the appliance will start heating whenever the room temperature falls below the selected temperature, regardless of timer or manual settings.

Follow these steps to set and operate the Set back feature:

1.Make sure the heater is turned OFF.

2.Press the “Set back” button. The light above the button will come on.

3.Press the up and down buttons to set the minimum temperature.

When the “Set back” indicator is on, frost protection is operating, and will always prevent the room temperature from falling below the pre-set minimum temperature (as long as electric power and gas is supplied).

To turn this feature off, press the “Set back” button.

The unit will retain its ON or OFF setting after a power failure. (Default setting at the factory is on.)

Humidifier and Air Flow Direction

Do not remove the bottom trim panel or the humidifier tray while warm air is flowing.

Adding Water to the Humidifier

Warm air is humidified when it passes over the water in the tray.

To fill the tray, remove the bottom panel by pushing on both sides and pulling it toward you. Pull the tray out and fill with water. Do not exceed the fill line. Push the tray back in and attach the bottom panel. Do not operate the appliance unless the humidifier tray is installed.

During operation a small amount of condensation is produced in the flue system and drains into the humidifier tray.

Do not adjust the air flow louvers while warm air is flowing.

Adjusting Air Flow Direction

The vertical louvers may be adjusted to move the air flow more to the right or to the left.

Use a screw driver or similar object to bend each louver to the desired position.

Do not bend repeatedly (no more than 5 times) or else the louver will break.

The horizontal louvers (which determines the vertical air flow direction) are fixed and cannot be adjusted.

10

Rinnai Corporation EX08C, EX11C Manual

Image 10
Contents EX11C RHFE-265FTA Owner’s Operation and Installation Manual for theEX08C RHFE-202FTA EnergysaverSpecifications Table of ContentsConsumer Safety Information Installation InstructionsSafety Behaviors and Practices Consumer Safety InformationSafety Definitions DANGERSafety Features SpecificationsAppliance Specifications Appliance Specifications FeaturesFlue Manifolds EX08COperating Instructions Getting to Know your New Heating ApplianceChild Lock Control PanelON / OFF Sensible Temperature ControlOperating the Heater Manually Setting the ClockSetting and Operating the Timers Setting the timersEconomy Energy Saving Mode Override FunctionEconomy Mode Information Humidifier and Air Flow Direction Adjusting Air Flow DirectionSet back Adding Water to the HumidifierCare of Exterior Care and MaintenanceMaintenance Snow AccumulationAt Ignition Before Making a Service CallWhen the unit is turned off During CombustionCODE DISPLAYED Fault CodesFAULT REMEDYBurnerdoesn’t ignite TroubleshootingRestart Function UnusualcombustionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesDrilling Flue Hole DimensionsFlue Hole D E B L Flue Terminal ClearancesH I M K Flue Terminal Clearances Canadian InstallationsUS Installations DescriptionFlue Manifold1Spare rubber seal Installation PartsFor weatherboard installations “A” Vent Kit, FOT-151Flue Manifold Installation Flue Manifold Installation 4. Install the Terminal Terminal sealExtension Kit Installation EX11C only Clamps Installing the Exhaust LineConnecting the Air Intake Hose Extension Kit Installation EX11C onlyItem Extension Kits and PartsExtension Kit Installation EX11C only Descriptionand slip the securing clip over the sleeve as Connecting the Applianceshown Propane Gas Adjust Gas Pressure SettingsNatural Gas EX08CAdjust Gas Pressure Settings Final AssemblyNormal Operating Sequence Visual Inspection of FlameOPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions TO TURN OFF GAS TO APPLIANCECut-AwayDiagram Rinnai Corporation EX08C, EX11C ManualAWG wire or its equivalent Wiring DiagramIf any of the original wire as supplied with the appliance must be replacedLadder Diagram For replacement parts call Rinnai at Parts ListRinnai Corporation EX08C, EX11C Manual Parts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualFor converting to NG Parts ListModel For converting to LPGConsumer Support Warranty InformationLimited Warranty Gas Direct Vent Wall FurnaceWhat is not covered? Limited Warranty - continuedHow do I get service? Limitation on warrantiesEX11C RHFE-265FTA Manuel d’installation et d’utilisation pourEX08C RHFE-202FTA EnergysaverService à la clientèle Table des matièresInstructions d’installation Sécurité du consommateurComportements et pratiques de sécurité Sécurité du consommateurDéfinitions de sécurité DANGERSpécifications de l’appareil SpécificationsDispositifs de sécurité EX08CSpécifications de l’appareil CaractéristiquesCollecteur de fumée EX08CInstructions d’utilisation Connaissance du nouveau chauffageVerrouillage pour les enfants Panneau de commandesMarche / Arrêt Contrôle de températureRéglage et utilisation des minuteries Mise à l’heureUtilisation manuelle du chauffage Paramétrage des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementInformations sur le mode déconomie dénergie Ajout deau dans lhumidificateur Programmation de température minimaleHumidificateur et direction du flux d’air Réglage de la direction du flux dairSoins pour l’extérieur Soins et entretienEntretien Accumulation de neigeAtÀ l’allumageIgnition Avant d’appeler pour de l’aideAutresOther pointsPoints DÉFAUT Codes de défautsCODE AFFICHÉ REMÈDEFonction de redémarrage DépannageInstructions d’installation Instructions généralesManuel de gaz robinet darrêt Connexion de gazDégagement par rapport aux combustibles zéro - voir la notification zéro 2 in 50 mmDégagements en sortie de cheminée Installations USA Dégagements en sortie de cheminée SuiteInstallations Canada DescriptionDimensions Percez le trou de conduite3 1/8 80 mm “A”“A”VentVentKit,Kit,FOTFOT-151-151 Pièces d’installationOwner’s Manual Ces pinces devraient être situés ici3 vis Installation du collecteur de fuméeRinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée Suite Rinnai Corporation EX08C, EX11C ManualInstallation du kit d’extension EX11C seulement Rinnai Corporation EX08C, EX11C ManualAttaches Installation de la conduite d’évacuationDégagements Connexion de la conduite d’évacuationItem Kits et pièces d’extensionInstallation du kit d’extension EX11C seulement DescriptionBranchement de l’appareil Gaz Propane Ajustage et Reglage de la Presion de GasGaz Naturel EX08CAssemblée finale La Séquence normale dOpérationLInspection visuelle de Flamme Ajustage et Reglage de la Presion de GasINSTRUCTIONS DE DÉMARRAGE Instructions de mise en œuvreCOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe besoin d’être remplacés, choisissez un fil de Schéma de câblageSi des fils d’origine livrés avec l’appareil ont calibre 18 AWG ou équivalentDiagramme logique Garantie limitée Service à la clientèleInformations de garantie Qu’est-cequi est couvert?Rinnai Corporation EX08C, EX11C Manual Garantie limitée SuiteComment obtenir le service sous garantie? Qu’est-cequi n’est pas couvert?Notes Rinnai Corporation EX08C, EX11C ManualNotes Rinnai Corporation EX08C, EX11C ManualRHF265-1091X0100Printed in Japan