Rinnai EX08C (RHFE-202FTA), EX11C (RHFE-265FTA) Override Function, Economy Energy Saving Mode

Page 9
Override Function

Override Function

This function is used only when the heater is in Timer operation.

It allows you to “override” the reset timer setting until the beginning of the next Timer period.

For example, if the heater is ON, pressing the “Override” button will turn the heater OFF until the next period. If the heater is OFF, pressing the “Override” button will turn the heater ON, and allow you to select a temperature setting, until the next period. The heater will remain on until the next timer period or until the Override function is turned off.

When in override function, pressing the “Override” button will return the heater to the operation of the current timer period.

Economy (Energy Saving Mode)

The Economy mode can only be set while the heater is operating (heating). Once it is set, it will remain in the system memory until deactivated.

1.To turn the Economy mode on, press the “Economy” button. The Economy indicator is lit.

The Economy mode now remains in the system memory.

If the appliance is turned off manually, or stops heating as a result of an OFF timer period, the “Economy “ indicator will go out.

Whenever the appliance starts heating again, the “Economy” indicator will light.

2.To turn the Economy mode off, press the “Economy” button. The “Economy “ indicator will go out.

The Economy mode can only be turned off while the heater is operating (heating) and when the “Economy” indicator is lit.

Economy Mode Information

After the room is heated initially, the air temperature may be dropped to a lower level without affecting comfort. The Economy Mode reduces the temperature by 2 ºF, 30 minutes after the room temperature setting is reached. After another 30 minutes, it reduces the temperature setting by another 2 ºF, effectively saving energy. The room temperature setting will drop up to a total of 4 ºF.

The Economy Mode will not operate if the heater is under capacity for the room size.

Preset Temperature

2°F reduction

2°F reduction

30 min

30 min

 

 

Rinnai Corporation EX08C, EX11C Manual

9

Image 9
Contents EX08C RHFE-202FTA Owner’s Operation and Installation Manual for theEX11C RHFE-265FTA EnergysaverConsumer Safety Information Table of ContentsSpecifications Installation InstructionsSafety Definitions Consumer Safety InformationSafety Behaviors and Practices DANGERSpecifications Safety FeaturesAppliance Specifications Flue Manifolds FeaturesAppliance Specifications EX08CGetting to Know your New Heating Appliance Operating InstructionsON / OFF Control PanelChild Lock Sensible Temperature ControlSetting and Operating the Timers Setting the ClockOperating the Heater Manually Setting the timersOverride Function Economy Energy Saving ModeEconomy Mode Information Set back Adjusting Air Flow DirectionHumidifier and Air Flow Direction Adding Water to the HumidifierMaintenance Care and MaintenanceCare of Exterior Snow AccumulationWhen the unit is turned off Before Making a Service CallAt Ignition During CombustionFAULT Fault CodesCODE DISPLAYED REMEDYRestart Function TroubleshootingBurnerdoesn’t ignite UnusualcombustionGeneral Instructions Installation InstructionsClearances to Combustibles Gas ConnectionDimensions Drilling Flue HoleFlue Hole Flue Terminal Clearances D E B LH I M K US Installations Canadian InstallationsFlue Terminal Clearances DescriptionFor weatherboard installations Installation PartsFlue Manifold1Spare rubber seal “A” Vent Kit, FOT-151Flue Manifold Installation 4. Install the Terminal Terminal seal Flue Manifold InstallationExtension Kit Installation EX11C only Connecting the Air Intake Hose Installing the Exhaust LineClamps Extension Kit Installation EX11C onlyExtension Kit Installation EX11C only Extension Kits and PartsItem DescriptionConnecting the Appliance and slip the securing clip over the sleeve asshown Natural Gas Adjust Gas Pressure SettingsPropane Gas EX08CNormal Operating Sequence Final AssemblyAdjust Gas Pressure Settings Visual Inspection of FlameOperating Instructions FOR YOUR SAFETY READ BEFORE OPERATINGOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCERinnai Corporation EX08C, EX11C Manual Cut-AwayDiagramIf any of the original wire as supplied Wiring DiagramAWG wire or its equivalent with the appliance must be replacedLadder Diagram Parts List For replacement parts call Rinnai atRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListRinnai Corporation EX08C, EX11C Manual Parts ListModel Parts ListFor converting to NG For converting to LPGLimited Warranty Warranty InformationConsumer Support Gas Direct Vent Wall FurnaceHow do I get service? Limited Warranty - continuedWhat is not covered? Limitation on warrantiesEX08C RHFE-202FTA Manuel d’installation et d’utilisation pourEX11C RHFE-265FTA EnergysaverInstructions d’installation Table des matièresService à la clientèle Sécurité du consommateurDéfinitions de sécurité Sécurité du consommateurComportements et pratiques de sécurité DANGERDispositifs de sécurité SpécificationsSpécifications de l’appareil EX08CCollecteur de fumée CaractéristiquesSpécifications de l’appareil EX08CConnaissance du nouveau chauffage Instructions d’utilisationMarche / Arrêt Panneau de commandesVerrouillage pour les enfants Contrôle de températureUtilisation manuelle du chauffage Mise à l’heureRéglage et utilisation des minuteries Paramétrage des minuteriesFonction de surpassement Économie Mode de conservation d’énergieInformations sur le mode déconomie dénergie Humidificateur et direction du flux d’air Programmation de température minimaleAjout deau dans lhumidificateur Réglage de la direction du flux dairEntretien Soins et entretienSoins pour l’extérieur Accumulation de neigeAvant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints CODE AFFICHÉ Codes de défautsDÉFAUT REMÈDEDépannage Fonction de redémarrageInstructions générales Instructions d’installationDégagement par rapport aux combustibles Connexion de gazManuel de gaz robinet darrêt zéro - voir la notification zéro 2 in 50 mmDégagements en sortie de cheminée Installations Canada Dégagements en sortie de cheminée SuiteInstallations USA DescriptionPercez le trou de conduite Dimensions3 1/8 80 mm Owner’s Manual Pièces d’installation“A”“A”VentVentKit,Kit,FOTFOT-151-151 Ces pinces devraient être situés iciInstallation du collecteur de fumée 3 visRinnai Corporation EX08C, EX11C Manual Rinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée SuiteRinnai Corporation EX08C, EX11C Manual Installation du kit d’extension EX11C seulementDégagements Installation de la conduite d’évacuationAttaches Connexion de la conduite d’évacuationInstallation du kit d’extension EX11C seulement Kits et pièces d’extensionItem DescriptionBranchement de l’appareil Gaz Naturel Ajustage et Reglage de la Presion de GasGaz Propane EX08CLInspection visuelle de Flamme La Séquence normale dOpérationAssemblée finale Ajustage et Reglage de la Presion de GasInstructions de mise en œuvre INSTRUCTIONS DE DÉMARRAGECOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe Si des fils d’origine livrés avec l’appareil ont Schéma de câblagebesoin d’être remplacés, choisissez un fil de calibre 18 AWG ou équivalentDiagramme logique Informations de garantie Service à la clientèleGarantie limitée Qu’est-cequi est couvert?Comment obtenir le service sous garantie? Garantie limitée SuiteRinnai Corporation EX08C, EX11C Manual Qu’est-cequi n’est pas couvert?Rinnai Corporation EX08C, EX11C Manual NotesRinnai Corporation EX08C, EX11C Manual NotesRHF265-1091X0100Printed in Japan