Rinnai EX11C (RHFE-265FTA), EX08C (RHFE-202FTA) Gas Connection, Clearances to Combustibles

Page 16
Gas Connection

Gas Connection

The gas supply line shall be gas tight, sized and so installed as to provide a supply of a gas sufficient to meet the maximum demand of the heater without loss of pressure.

A shut off valve and appliance connector valve should be installed in the upstream of the gas line to permit servicing.

Flexible pipe and any appliance connector valve used for gas piping shall be types approved by nationally recognized agencies.

Check the gas supply pressure immediately upstream at a location provided by the gas company. Supplied gas pressure must be within the limits shown in the Specifications section.

Refer to an approved pipe sizing chart if in doubt about the size of the gas line.

Install the provided manual gas shut-off valve so that it can be accessed for easy operation. Do not conceal manual cut-off valve behind back spacer.

Any compound used on the threaded joint of the gas piping shall be a type which resists the action of liquefied petroleum gas (propane / LPG).

After completion of gas pipe connections all joints including the heater must be checked for gas tightness by means of leak detector solution, soap and water, or an equivalent nonflammable solution, as applicable. (Since some leak test solutions, including soap and water, may cause corrosion or stress cracking, the piping shall be rinsed with water after testing, unless it has been determined that the leak test solution is non-corrosive.)

Clearances to Combustibles

Manual gas shut-off valve

When determining where to install the appliance

 

Zero - See Notice

the clearances to combustibles shown in the

 

 

 

figure must be followed. Also refer to the Safety

 

 

 

Behaviors and Practices section.

 

 

 

 

 

 

 

 

 

 

Zero

 

 

 

 

 

2 in

 

(50 mm)

 

 

2 in

(50 mm)

 

40 in

 

(1 m)

16

Rinnai Corporation EX08C, EX11C Manual

Image 16
Contents Owner’s Operation and Installation Manual for the EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable of Contents Consumer Safety InformationSpecifications Installation InstructionsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices DANGERSafety Features SpecificationsAppliance Specifications Features Flue ManifoldsAppliance Specifications EX08COperating Instructions Getting to Know your New Heating ApplianceControl Panel ON / OFFChild Lock Sensible Temperature ControlSetting the Clock Setting and Operating the TimersOperating the Heater Manually Setting the timersEconomy Energy Saving Mode Override FunctionEconomy Mode Information Adjusting Air Flow Direction Set backHumidifier and Air Flow Direction Adding Water to the HumidifierCare and Maintenance MaintenanceCare of Exterior Snow AccumulationBefore Making a Service Call When the unit is turned offAt Ignition During CombustionFault Codes FAULTCODE DISPLAYED REMEDYTroubleshooting Restart FunctionBurnerdoesn’t ignite UnusualcombustionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesDrilling Flue Hole DimensionsFlue Hole D E B L Flue Terminal ClearancesH I M K Canadian Installations US InstallationsFlue Terminal Clearances DescriptionInstallation Parts For weatherboard installationsFlue Manifold1Spare rubber seal “A” Vent Kit, FOT-151Flue Manifold Installation Flue Manifold Installation 4. Install the Terminal Terminal sealExtension Kit Installation EX11C only Installing the Exhaust Line Connecting the Air Intake HoseClamps Extension Kit Installation EX11C onlyExtension Kits and Parts Extension Kit Installation EX11C onlyItem Descriptionand slip the securing clip over the sleeve as Connecting the Applianceshown Adjust Gas Pressure Settings Natural GasPropane Gas EX08CFinal Assembly Normal Operating SequenceAdjust Gas Pressure Settings Visual Inspection of FlameFOR YOUR SAFETY READ BEFORE OPERATING Operating InstructionsOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCECut-AwayDiagram Rinnai Corporation EX08C, EX11C ManualWiring Diagram If any of the original wire as suppliedAWG wire or its equivalent with the appliance must be replacedLadder Diagram For replacement parts call Rinnai at Parts ListRinnai Corporation EX08C, EX11C Manual Parts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List ModelFor converting to NG For converting to LPGWarranty Information Limited WarrantyConsumer Support Gas Direct Vent Wall FurnaceLimited Warranty - continued How do I get service?What is not covered? Limitation on warrantiesManuel d’installation et d’utilisation pour EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable des matières Instructions d’installationService à la clientèle Sécurité du consommateurSécurité du consommateur Définitions de sécuritéComportements et pratiques de sécurité DANGERSpécifications Dispositifs de sécuritéSpécifications de l’appareil EX08CCaractéristiques Collecteur de fuméeSpécifications de l’appareil EX08CInstructions d’utilisation Connaissance du nouveau chauffagePanneau de commandes Marche / ArrêtVerrouillage pour les enfants Contrôle de températureMise à l’heure Utilisation manuelle du chauffageRéglage et utilisation des minuteries Paramétrage des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementInformations sur le mode déconomie dénergie Programmation de température minimale Humidificateur et direction du flux d’airAjout deau dans lhumidificateur Réglage de la direction du flux dairSoins et entretien EntretienSoins pour l’extérieur Accumulation de neigeAtÀ l’allumageIgnition Avant d’appeler pour de l’aideAutresOther pointsPoints Codes de défauts CODE AFFICHÉDÉFAUT REMÈDEFonction de redémarrage DépannageInstructions d’installation Instructions généralesConnexion de gaz Dégagement par rapport aux combustiblesManuel de gaz robinet darrêt zéro - voir la notification zéro 2 in 50 mmDégagements en sortie de cheminée Dégagements en sortie de cheminée Suite Installations CanadaInstallations USA DescriptionDimensions Percez le trou de conduite3 1/8 80 mm Pièces d’installation Owner’s Manual“A”“A”VentVentKit,Kit,FOTFOT-151-151 Ces pinces devraient être situés ici3 vis Installation du collecteur de fuméeRinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée Suite Rinnai Corporation EX08C, EX11C ManualInstallation du kit d’extension EX11C seulement Rinnai Corporation EX08C, EX11C ManualInstallation de la conduite d’évacuation DégagementsAttaches Connexion de la conduite d’évacuationKits et pièces d’extension Installation du kit d’extension EX11C seulementItem DescriptionBranchement de l’appareil Ajustage et Reglage de la Presion de Gas Gaz NaturelGaz Propane EX08CLa Séquence normale dOpération LInspection visuelle de FlammeAssemblée finale Ajustage et Reglage de la Presion de GasINSTRUCTIONS DE DÉMARRAGE Instructions de mise en œuvreCOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe Schéma de câblage Si des fils d’origine livrés avec l’appareil ontbesoin d’être remplacés, choisissez un fil de calibre 18 AWG ou équivalentDiagramme logique Service à la clientèle Informations de garantieGarantie limitée Qu’est-cequi est couvert?Garantie limitée Suite Comment obtenir le service sous garantie?Rinnai Corporation EX08C, EX11C Manual Qu’est-cequi n’est pas couvert?Notes Rinnai Corporation EX08C, EX11C ManualNotes Rinnai Corporation EX08C, EX11C ManualRHF265-1091X0100Printed in Japan