Adjust Gas Pressure Settings

6.Press the test switch twice to record the gas type code into memory. .

7.Press the ON/OFF button to operate the appliance.

8.Press the test switch twice. The LED will display “PL”.

9.Compare the pressure reading on the manometer to the desired manifold test pressure (low) for your gas type and altitude. If necessary adjust the low fire pressure using the ▲ and ▼ buttons.

10.Press the test switch. The LED will display “PH” indicating high fire mode.

11.Compare the pressure reading on the manometer to the desired manifold test pressure (high) for your gas type and altitude. If necessary adjust the high fire pressure using the ▲ and ▼ buttons.

12.Press the ON/OFF button again. The LED display turns blank and the appliance returns to the normal OFF mode.

13.Remove manometer and install Allen head screws. Operate the unit and

check the normal operating sequence

visually inspect the flame

check for gas leaks at the test points

Normal Operating Sequence

When you press the ON/OFF button, the LED display will illuminate, the combustion fan will begin to run, and the spark will ignite the main burner.

This heater has an automatic ignition system. When the main burner has lit, the combustion lamp will glow red, and the spark will stop.

Visual Inspection of Flame

Check that the burner flames are operating normally. The flame can be seen through the circular window through the louvers.

When operating normally the burner flame should appear as long, clear, blue, stable, streaks. Yellow flames or an orange color is abnormal and maintenance is required.

NORMAL

Flame Rod

Long, clear, blue, stable flames

ABNORMAL

Flame Rod Final Assembly

Yellow flames orManual background orange color

Final Assembly

1.Install the front panel and bottom cover.

2.If doing a gas type conversion, place the new conversion plate (label) on the front cover.

28

Rinnai Corporation EX08C, EX11C Manual

Image 28
Contents Owner’s Operation and Installation Manual for the EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable of Contents Consumer Safety InformationSpecifications Installation InstructionsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices DANGERSafety Features SpecificationsAppliance Specifications Features Flue ManifoldsAppliance Specifications EX08COperating Instructions Getting to Know your New Heating ApplianceControl Panel ON / OFFChild Lock Sensible Temperature ControlSetting the Clock Setting and Operating the TimersOperating the Heater Manually Setting the timersEconomy Energy Saving Mode Override FunctionEconomy Mode Information Adjusting Air Flow Direction Set backHumidifier and Air Flow Direction Adding Water to the HumidifierCare and Maintenance MaintenanceCare of Exterior Snow AccumulationBefore Making a Service Call When the unit is turned offAt Ignition During CombustionFault Codes FAULTCODE DISPLAYED REMEDYTroubleshooting Restart FunctionBurnerdoesn’t ignite UnusualcombustionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesDrilling Flue Hole DimensionsFlue Hole D E B L Flue Terminal ClearancesH I M K Canadian Installations US InstallationsFlue Terminal Clearances DescriptionInstallation Parts For weatherboard installationsFlue Manifold1Spare rubber seal “A” Vent Kit, FOT-151Flue Manifold Installation Flue Manifold Installation 4. Install the Terminal Terminal sealExtension Kit Installation EX11C only Installing the Exhaust Line Connecting the Air Intake HoseClamps Extension Kit Installation EX11C onlyExtension Kits and Parts Extension Kit Installation EX11C onlyItem Descriptionand slip the securing clip over the sleeve as Connecting the Applianceshown Adjust Gas Pressure Settings Natural GasPropane Gas EX08CFinal Assembly Normal Operating SequenceAdjust Gas Pressure Settings Visual Inspection of FlameFOR YOUR SAFETY READ BEFORE OPERATING Operating InstructionsOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCECut-AwayDiagram Rinnai Corporation EX08C, EX11C ManualWiring Diagram If any of the original wire as suppliedAWG wire or its equivalent with the appliance must be replacedLadder Diagram For replacement parts call Rinnai at Parts ListRinnai Corporation EX08C, EX11C Manual Parts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List ModelFor converting to NG For converting to LPGWarranty Information Limited WarrantyConsumer Support Gas Direct Vent Wall FurnaceLimited Warranty - continued How do I get service?What is not covered? Limitation on warrantiesManuel d’installation et d’utilisation pour EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable des matières Instructions d’installationService à la clientèle Sécurité du consommateurSécurité du consommateur Définitions de sécuritéComportements et pratiques de sécurité DANGERSpécifications Dispositifs de sécuritéSpécifications de l’appareil EX08CCaractéristiques Collecteur de fuméeSpécifications de l’appareil EX08CInstructions d’utilisation Connaissance du nouveau chauffagePanneau de commandes Marche / ArrêtVerrouillage pour les enfants Contrôle de températureMise à l’heure Utilisation manuelle du chauffageRéglage et utilisation des minuteries Paramétrage des minuteriesÉconomie Mode de conservation d’énergie Fonction de surpassementInformations sur le mode déconomie dénergie Programmation de température minimale Humidificateur et direction du flux d’airAjout deau dans lhumidificateur Réglage de la direction du flux dairSoins et entretien EntretienSoins pour l’extérieur Accumulation de neigeAtÀ l’allumageIgnition Avant d’appeler pour de l’aideAutresOther pointsPoints Codes de défauts CODE AFFICHÉDÉFAUT REMÈDEFonction de redémarrage DépannageInstructions d’installation Instructions généralesConnexion de gaz Dégagement par rapport aux combustiblesManuel de gaz robinet darrêt zéro - voir la notification zéro 2 in 50 mmDégagements en sortie de cheminée Dégagements en sortie de cheminée Suite Installations CanadaInstallations USA DescriptionDimensions Percez le trou de conduite3 1/8 80 mm Pièces d’installation Owner’s Manual“A”“A”VentVentKit,Kit,FOTFOT-151-151 Ces pinces devraient être situés ici3 vis Installation du collecteur de fuméeRinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée Suite Rinnai Corporation EX08C, EX11C ManualInstallation du kit d’extension EX11C seulement Rinnai Corporation EX08C, EX11C ManualInstallation de la conduite d’évacuation DégagementsAttaches Connexion de la conduite d’évacuationKits et pièces d’extension Installation du kit d’extension EX11C seulementItem DescriptionBranchement de l’appareil Ajustage et Reglage de la Presion de Gas Gaz NaturelGaz Propane EX08CLa Séquence normale dOpération LInspection visuelle de FlammeAssemblée finale Ajustage et Reglage de la Presion de GasINSTRUCTIONS DE DÉMARRAGE Instructions de mise en œuvreCOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe Schéma de câblage Si des fils d’origine livrés avec l’appareil ontbesoin d’être remplacés, choisissez un fil de calibre 18 AWG ou équivalentDiagramme logique Service à la clientèle Informations de garantieGarantie limitée Qu’est-cequi est couvert?Garantie limitée Suite Comment obtenir le service sous garantie?Rinnai Corporation EX08C, EX11C Manual Qu’est-cequi n’est pas couvert?Notes Rinnai Corporation EX08C, EX11C ManualNotes Rinnai Corporation EX08C, EX11C ManualRHF265-1091X0100Printed in Japan