Rinnai EX11C (RHFE-265FTA) Clamps, Installing the Exhaust Line, Connecting the Air Intake Hose

Page 24
Clamps

Extension Kit Installation (EX11C only)

Clearances exhaust pipe to combustibles

1 inch (25.4 mm)

exhaust pipe to non-combustibles

zero

Clamps

Exhaust pipe

Both the exhaust line and air intake hose are

Exhaust pipe

 

supported by clamps which are attached to the wall.

 

A wall fixture can be used to offset the clamp from the

 

wall. Use Screw B to attach the wall fixture to the

 

wall. If the wall fixture is not used then use Screw A

 

and the nut to attach the clamp to the wall.

 

The air intake hose should always be underneath the

 

exhaust line so that in case the air line sags it will not

 

come into contact with the exhaust line.

Air intake hose

 

 

Air intake hose

Installing the Exhaust Line

The exhaust line is connected between the bent pipe at the rear of the heater and the exhaust port on the flue manifold.

To connect exhaust pipes with other straight pipes or bends, fit the male end into the female end. Use pipe stopper A to clamp the connection.

Use pipe stopper B to fix the length on the adjustable exhaust pipes. Do not extend these pipes beyond the red line.

Do not cut the exhaust pipe. Use the adjustable pipes if necessary.

To bend the elbow, insert exhaust pipes into both ends for additional leverage. Bend to desired angle.

Do not straighten the bent pipe attached to the appliance.

Connecting the Air Intake Hose

The air intake hose is connected between the air connection at the rear of the heater and the air intake port on the flue manifold.

Push the air intake hose onto the flue manifold and secure with the plastic cable tie.

Join air intake hoses by screwing the hose joint half of its length into the air intake hose and then screwing another air intake hose into the hose joint.

Male end

Female end

Pipe stopper B

 

Installing the Exhaust LineConnecting the Air Intake HoseManual backgroundPipe stopper A

Adjust the angle

The lengths of the air intake hose and the exhaust pipe must be the same in order for the appliance to operate properly. The hose can be cut to the required length. Deburr all rough edges. Do not cut the hose attached to the appliance.

Support the air intake hose with pipe clamps. Hose joint

Air intake hoses

24

Rinnai Corporation EX08C, EX11C Manual

Image 24
Contents Owner’s Operation and Installation Manual for the EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable of Contents Consumer Safety InformationSpecifications Installation InstructionsConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices DANGERSpecifications Safety FeaturesAppliance Specifications Features Flue ManifoldsAppliance Specifications EX08COperating Instructions Getting to Know your New Heating ApplianceControl Panel ON / OFFChild Lock Sensible Temperature ControlSetting the Clock Setting and Operating the TimersOperating the Heater Manually Setting the timersOverride Function Economy Energy Saving ModeEconomy Mode Information Adjusting Air Flow Direction Set backHumidifier and Air Flow Direction Adding Water to the HumidifierCare and Maintenance MaintenanceCare of Exterior Snow AccumulationBefore Making a Service Call When the unit is turned offAt Ignition During CombustionFault Codes FAULTCODE DISPLAYED REMEDYTroubleshooting Restart FunctionBurnerdoesn’t ignite UnusualcombustionInstallation Instructions General InstructionsGas Connection Clearances to CombustiblesDimensions Drilling Flue HoleFlue Hole Flue Terminal Clearances D E B LH I M K Canadian Installations US InstallationsFlue Terminal Clearances DescriptionInstallation Parts For weatherboard installationsFlue Manifold1Spare rubber seal “A” Vent Kit, FOT-151Flue Manifold Installation Flue Manifold Installation 4. Install the Terminal Terminal sealExtension Kit Installation EX11C only Installing the Exhaust Line Connecting the Air Intake HoseClamps Extension Kit Installation EX11C onlyExtension Kits and Parts Extension Kit Installation EX11C onlyItem DescriptionConnecting the Appliance and slip the securing clip over the sleeve asshown Adjust Gas Pressure Settings Natural GasPropane Gas EX08CFinal Assembly Normal Operating SequenceAdjust Gas Pressure Settings Visual Inspection of FlameFOR YOUR SAFETY READ BEFORE OPERATING Operating InstructionsOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCECut-AwayDiagram Rinnai Corporation EX08C, EX11C ManualWiring Diagram If any of the original wire as suppliedAWG wire or its equivalent with the appliance must be replacedLadder Diagram Parts List For replacement parts call Rinnai atRinnai Corporation EX08C, EX11C Manual Parts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List Rinnai Corporation EX08C, EX11C ManualParts List ModelFor converting to NG For converting to LPGWarranty Information Limited WarrantyConsumer Support Gas Direct Vent Wall FurnaceLimited Warranty - continued How do I get service?What is not covered? Limitation on warrantiesManuel d’installation et d’utilisation pour EX08C RHFE-202FTAEX11C RHFE-265FTA EnergysaverTable des matières Instructions d’installationService à la clientèle Sécurité du consommateurSécurité du consommateur Définitions de sécuritéComportements et pratiques de sécurité DANGERSpécifications Dispositifs de sécuritéSpécifications de l’appareil EX08CCaractéristiques Collecteur de fuméeSpécifications de l’appareil EX08CInstructions d’utilisation Connaissance du nouveau chauffagePanneau de commandes Marche / ArrêtVerrouillage pour les enfants Contrôle de températureMise à l’heure Utilisation manuelle du chauffageRéglage et utilisation des minuteries Paramétrage des minuteriesFonction de surpassement Économie Mode de conservation d’énergieInformations sur le mode déconomie dénergie Programmation de température minimale Humidificateur et direction du flux d’airAjout deau dans lhumidificateur Réglage de la direction du flux dairSoins et entretien EntretienSoins pour l’extérieur Accumulation de neigeAvant d’appeler pour de l’aide AtÀ l’allumageIgnitionAutresOther pointsPoints Codes de défauts CODE AFFICHÉDÉFAUT REMÈDEFonction de redémarrage DépannageInstructions d’installation Instructions généralesConnexion de gaz Dégagement par rapport aux combustiblesManuel de gaz robinet darrêt zéro - voir la notification zéro 2 in 50 mmDégagements en sortie de cheminée Dégagements en sortie de cheminée Suite Installations CanadaInstallations USA DescriptionPercez le trou de conduite Dimensions3 1/8 80 mm Pièces d’installation Owner’s Manual“A”“A”VentVentKit,Kit,FOTFOT-151-151 Ces pinces devraient être situés iciInstallation du collecteur de fumée 3 visRinnai Corporation EX08C, EX11C Manual Installation du collecteur de fumée Suite Rinnai Corporation EX08C, EX11C ManualInstallation du kit d’extension EX11C seulement Rinnai Corporation EX08C, EX11C ManualInstallation de la conduite d’évacuation DégagementsAttaches Connexion de la conduite d’évacuationKits et pièces d’extension Installation du kit d’extension EX11C seulementItem DescriptionBranchement de l’appareil Ajustage et Reglage de la Presion de Gas Gaz NaturelGaz Propane EX08CLa Séquence normale dOpération LInspection visuelle de FlammeAssemblée finale Ajustage et Reglage de la Presion de GasInstructions de mise en œuvre INSTRUCTIONS DE DÉMARRAGECOUPURE DE L’ALIMENTATION EN GAZ DE L’APPAREIL Schéma en coupe Schéma de câblage Si des fils d’origine livrés avec l’appareil ontbesoin d’être remplacés, choisissez un fil de calibre 18 AWG ou équivalentDiagramme logique Service à la clientèle Informations de garantieGarantie limitée Qu’est-cequi est couvert?Garantie limitée Suite Comment obtenir le service sous garantie?Rinnai Corporation EX08C, EX11C Manual Qu’est-cequi n’est pas couvert?Notes Rinnai Corporation EX08C, EX11C ManualNotes Rinnai Corporation EX08C, EX11C ManualRHF265-1091X0100Printed in Japan