Parts layout on the outdoor unit PCB
SFDCVA151~251 type
Sub PCB
(Noise filter)
T5
T2
T1
T4
F2
CNI
W | T8 |
V | T7 |
CN |
|
U | T6 |
Power transistor thermistor
Reactor
Fan motor
Stepping motor
F3 | CNM | CNV1 | CNI2 |
F1 |
|
|
|
CNW
CNI3
| SW7 |
| CNE |
CNQ | SW6 |
DIP switch | DIP switch |
(SW6) | (SW7) |
CNL CNTR
Outdoor air temp. thermistor, Outdoor heat exchanger themistor, Discharge pipe thermistor
●Change by the jumper wire
Model | 151 | 201 | 251 |
JA1 | None | None | None |
JA5 | None | None | None |
JA6 | None | With | None |
JA7 | None | None | With |
JA8 | With | With | With |
Notes (1) “None” means that jumper wire is not provided on the PCB or the connection is cut
(2)The replacement PCB is not equipped with jumper wires JA1 and JA5~JA8. Instead, SW6 and 7 are mounted in the same position and have the same functions as jumper wires JA1 and JA5~JA8. Carry out the local settings in accordance with the table using SW6 and 7.
●Function of DIP switches (SW5) (Usually all turned OFF)
Switch | Function | ||
ON | Defrost Setting Select For cold regions. | ||
OFF | Normal | ||
| |||
ON | |||
OFF | |||
ON | Low refrigerant protection | ||
OFF | Low refrigerant protection | ||
| |||
ON | Test run | ||
OFF | Test run | ||
|
●Change by the JA3
Switch | Function | |
JA3 | with | Model |
None | Model |
Note (1) “None” means that jumper wire is not provided on the PCB or the connection is cut.
External PCB
SW5 SW9
Test run operation switch
SW5SW9
1 2 3 4
CNQ1