Hunter Fan R410A manual Function setting method, When Function is selected

Page 40
- 38 -
AUTO RUN SET
Function description:
Function number: A
B

(b) Function setting method

1) Stop the air conditioner

Operating guide message

 

Function description: B , Settting: C

Function number: A

 

 

2) Press the SET and MODE buttons simultaneously

 

 

for 3 seconds or longer.

 

 

The screen display will be switched as follows:

 

Confirm Button

 

 

 

SELECT ITEM”

AUTO RUN SET

SET"

 

ON/OFF Button

“FUNCTION SET ”

 

 

 

FUNCTION SET

 

Start Button

3) Press the SET button.

Selector button

 

 

 

The unit will enter the function setting mode. The

 

 

screen display will charge to “ FUNCTION

Indoor unit selector button

Previous screen button

”.

 

 

4)Check which category your desired setting belongs to, “ FUNCTION (Remote controller unit function)” or “I/U FUNCTION " (Indoor unit function).

5)Press either or button.

Select either “ FUNCTION ” or “I/U FUNCTION ”.

FUNCTION I/U FUNCTION

6) Press the SET button.

When “ FUNCTION ” is selected.

1“DATA LOADING” (blinking) FUNCTION” “GRILLE SET” (Function number: A, Function description: B) The screen display will be switched like this.

2Press either or button.

“Function number: A, Function description: B “from the list of remote controller unit functions will be displayed one by one. Select a desired function.

3Press the SET button.

The screen display will be switched as follows:

SETTING” “Setting: C” (ex. “AUTO RUN ON”)

4Press either or button.

A list of “Settings: C” will be displayed one by one. Select your desired setting.

5 Press the SET button.

The selected setting is displayed

for 2 seconds, then followed by “SET COMPLETE” and the function setting process is com- pleted.

Then the screen display will be

* When “ AUTO RUN SET ” is selected.

swiched to “Function number:

AUTO RUN ON

Setting: C

A, Function description: B,” so

 

 

 

if you want to comtinue to set

AUTO RUN ON

AUTO RUN OFF

another function, repeat the steps

as explained above.

 

 

To finish the function setting pro-

 

SET COMPLETE

cess, please proceed to Step (c).

 

 

 

Image 40
Contents FDA Series Split Systems FDA Series Multi Systems Page Index Evacuation procedure EvacuationRefrigerant charging High side Low sideIndi Cation CircuitSelfdiagnosis function Check Indicator Table Indoor unit sideNo-indication E10 E16 E28 Indoor unit LED Outdoor unit LEDOutdoor unit side Timing of error detection Display sequence of error, inspection display lampWait Recording and reset of error Procedures of trouble diagnosisError diagnosis procedures at the indoor unit side Indoor unit Outdoor unitControl change switch SW5, SW9, SW10 Change by the jumper wireParts layout on the indoor unit PCB Model FDT series Model Fden series Model Fdkn series Model Fdur series Drain motorCheck method when the error code is display Indoor unit Outdoor unitRemote controller wire Is removed Replacement indoor Unit control PCBRed LED Time flash Stays OFF Green LED Keeps flashing ApproximatelyRed LED 151~251301~601 Only case of FDT Cases of other than FDTRed LED Stays OFF Green LED Stays OFF or LightsError display Detective return air thermistor Error display e6Defective indoor unit heat exchanger thermistor Error display Heating overload Abnormal Temperature DetectionError display Drain trouble Indoor unit heat exchanger temp. ˚CError display Error display e16 Fan motor abnormalitiesE10 Only case of FDTA501, 601 typesOnly case of Fdkn Only case of 151~251 types Display conditionsWithin a period of 1 hour Only case of 301 typeError display e28 Directive remote controller thermistor Are characteristicsDetectivie remote controller PCB Remote controller therm Replacement Detective reError diagnosis procedures at the outdoor units side Change by the jumper wire Function of DIP switches SW5 Usually all turned OFFParts layout on the outdoor unit PCB FDCVA151~251 type Change by the JA3Overcurrent Setting FDCA301~601 typePower transistor module Power supply phases reversed Only case of 301~601 type Error display Communications error during operationE32 Inverter primary current abnormal Only case of 151~251 type E33Compressor overcurrent trouble Only case of 301~601 type Error display e35 Cooling overload operation E34Abnormal Temperature Detection Error display e36 Discharge temperature errorPressor is stopped Error display e39 Defective discharge pipe thermistor Utes100 80 COpen phase at L3-phase of 52C primary side Error display e40 63H1 operation Only case of 301~601 typeError display e42 Current cut Only case of 151~251 type Error display e52 52C Abnormal Only case of 301~601 type E47E48 Inverter over-voltage trouble Only case of 151~251 typeInsufficient refrigerant volume E57Did it improve? Replacement Compressor Could be causingRefrigerant circuit Malfunction. IfPower transistor module including drive circuit check method Is the powerCheck abnormal operation data with the remote controller Remote controller Wired remote controller Pull the cover downward to open itRemote controller unit functions Indoor unit functions I/U FunctionFunction setting method When Function is selectedWhen I/U Function is selected Press the ON/OFF buttonChanging the remote controller’s temperature setting range Cooling Test Operation Procedure Canceling the Cooling Test OperationStarting the Cooling Test Operation Checking Operation DataSetting SW5-1, SW5-2 on-site Test run Test run methodChecking the state of the unit in operation HeatingIndication board Fden Series Fdkn SeriesWireless remote controller Page Installation of this equipment must comply with all NATIONAL, State and Local Codes