Hunter Fan R410A manual Wireless remote controller

Page 46

(c) Wireless remote controller

OPERATION MODE indicator

Indicates selected operation mode

Fan speed

Indicates the selected fan speed

Auto swing

Indicates the selection of swing louver.

Timer ON time

Indicates the timer ON time.

When the timer mode is “CONT” or “OFF”, the present time is indicated.

OPERATION MODE select button

This button, whenever pressed, changes the mode in the following order.

AUTO COOL DRY

HEAT FAN

FAN SPEED button

Every time when the button is pressed, the mode is sequentially changed HI LOW.

Air flow direction button

Used to start or stop the swing louver.

Timer mode button

Every time when the button is pressed, the mode is sequentially changed CONT ON

OFF PROGRAM.

Reset switch

Used to reset the microcomputer when some- thing is wrong on the remote controller dis- play.

Above figure shows all indications for the purpose of explanation, but practically only the pertinent parts are indicated.

AUTO COOL DRY FAN HEAT FILTER

FAN HI ME LO

°C

ON AMPM OFF AMPM

MODE TEMP ON/OFF

FAN SPEED

AIR FLOW

FILTER

TIMER

SET

 

ACL

 

TIME

Signal sender

Signals are sent to the air conditioner from here.

Filter reset indicator

The FILTER mark is indicated when the FILTER RESET button is pressed.

Temperature indicator

Set temperature is indicated.

Timer OFF time

Indicated the timer OFF time.

When the timer mode is “CONT” or “OFF”, there is no indication.

ON/OFF button

When the button is pressed, the air conditioner is started, and when the button is pressed once again, it is stopped. (When the air conditioner is stopped, the present time only is indicated. When the air conditioner is operating, details of setting are indicated.)

ROOM TEMP. button

Room temperature is set within the range of 18-30˚C by operating the ,

or button.

Filter button

Used to reset (turn off) the filter sign. (Press for more than 1 second.)

Press the button only after completing the filter cleaning.

TIME button

Used to set the present time and the timer operation time.

Set button

Used to switch from the hour to minute or vice versa when setting the present time or timer operation time.

Clock switch

Press this before setting the present time.

- 44 -

Image 46
Contents FDA Series Split Systems FDA Series Multi Systems Page Index Evacuation procedure EvacuationIndi Refrigerant chargingHigh side Low side Cation CircuitNo-indication Selfdiagnosis function Check Indicator TableIndoor unit side E10 E16 E28 Indoor unit LED Outdoor unit LEDOutdoor unit side Timing of error detection Display sequence of error, inspection display lampWait Error diagnosis procedures at the indoor unit side Recording and reset of errorProcedures of trouble diagnosis Indoor unit Outdoor unitControl change switch SW5, SW9, SW10 Change by the jumper wireParts layout on the indoor unit PCB Model FDT series Model Fden series Model Fdkn series Model Fdur series Drain motorCheck method when the error code is display Indoor unit Outdoor unitRed LED Time flash Stays OFF Green LED Keeps flashing Remote controller wire Is removedReplacement indoor Unit control PCB ApproximatelyRed LED 151~251301~601 Red LED Stays OFF Only case of FDTCases of other than FDT Green LED Stays OFF or LightsError display Detective return air thermistor Error display e6Defective indoor unit heat exchanger thermistor Error display Drain trouble Error display Heating overloadAbnormal Temperature Detection Indoor unit heat exchanger temp. ˚CE10 Error displayError display e16 Fan motor abnormalities Only case of FDTA501, 601 typesWithin a period of 1 hour Only case of Fdkn Only case of 151~251 typesDisplay conditions Only case of 301 typeDetectivie remote controller PCB Error display e28 Directive remote controller thermistorAre characteristics Remote controller therm Replacement Detective reError diagnosis procedures at the outdoor units side Parts layout on the outdoor unit PCB FDCVA151~251 type Change by the jumper wireFunction of DIP switches SW5 Usually all turned OFF Change by the JA3Overcurrent Setting FDCA301~601 typePower transistor module Power supply phases reversed Only case of 301~601 type Error display Communications error during operationE32 Inverter primary current abnormal Only case of 151~251 type E33Compressor overcurrent trouble Only case of 301~601 type Error display e35 Cooling overload operation E34Abnormal Temperature Detection Error display e36 Discharge temperature errorPressor is stopped 100 Error display e39 Defective discharge pipe thermistorUtes 80 COpen phase at L3-phase of 52C primary side Error display e40 63H1 operation Only case of 301~601 typeError display e42 Current cut Only case of 151~251 type E48 Error display e52 52C Abnormal Only case of 301~601 typeE47 Inverter over-voltage trouble Only case of 151~251 typeInsufficient refrigerant volume E57Refrigerant circuit Did it improve? Replacement CompressorCould be causing Malfunction. IfPower transistor module including drive circuit check method Is the powerCheck abnormal operation data with the remote controller Remote controller Wired remote controller Pull the cover downward to open itRemote controller unit functions Indoor unit functions I/U FunctionFunction setting method When Function is selectedWhen I/U Function is selected Press the ON/OFF buttonChanging the remote controller’s temperature setting range Starting the Cooling Test Operation Cooling Test Operation ProcedureCanceling the Cooling Test Operation Checking Operation DataChecking the state of the unit in operation Setting SW5-1, SW5-2 on-siteTest run Test run method HeatingIndication board Fden Series Fdkn SeriesWireless remote controller Page Installation of this equipment must comply with all NATIONAL, State and Local Codes