Enviro
EA800
owner manual
D-011-0152
Troubleshooting
Specs
Install
Block Diagrams
To alarm-on-closed
Password
Connecting Wired 4-20mASensors
Maintenance
Configuring the Relays
Reset Button
Page 1
Electronic
Multi-Zone
Environmental Alarm System Installation/Owner’s Manual
D-011-0152
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
D-011-0152
Limitations of the Alarm System or Device
Installation
Table of Contents
General Information
Preparation
Operation
Overview
General Information
How to Use This Manual
General Information
Block Diagrams
D-011-0152
Symbols on the Product or Manual Labeling
General Information
Monitoring Screens
D-011-0152
Keys
Base Unit Connections
Access Control and Passwords
will sound when an alarm occurs if DISABLE is
System Configuration Parameters
selected
Temperature Sensors
Sensors
4-20mASensors
Humidity Sensors
Theory of Operation
Power Supply / Sensor Voltage Selection
Multi-FunctionSensors
Water Sensors
Contact Closure Sensors
Resolution
Sensor Parameter Descriptions
Maximum Allowed
High Scaled Value
Relay Operation
D-011-0152
Relay Operation
Preparation
D-011-0152
To alarm-on-closed
From 11-26VDC power supply
loop circuit power supplied via loop
From 11-26VDC power supply
D-011-0152
Power Requirements
Installation
Tools and Supplies Required
Mounting the EA800 Rear Plate
EA800 Base Unit Power Connections
Install the Wired Sensors
Install the Wireless Sensors
SENSOR MODEL NO
RESET BUTTON
SENSOR MODEL NO
RESET BUTTON
D-011-0152
J6 Input 1 Input 2 Input 3 Input
Connecting Wired HA-III+Humidity Sensors
Connecting Wired 4-20mASensors
Programming
Connecting the EA800 Alarm Outputs
Configuring System Parameter Settings
Accessing the MAIN MENU for Programming
3.Enter the SYSTEM menu and then select the CONFIGURATION menu as shown below
DISABLED is selected
Setting the Current Date
D-011-0152
Setting the Time
Adding a Wireless Temperature Sensor
Adding Wireless Sensors
D-011-0152
Adding Wireless Sensors
D-011-0152
Installation
D-011-0152
Installation
Adding a Wireless Humidity Sensor
D-011-0152
D-011-0152
D-011-0152
Installation
D-011-0152
Select N.O. Contact or N.C. Contact
Installation
D-011-0152
D-011-0152
Verify Wireless Signal Strength
Adding a Wired Temperature Sensor
Adding Wired Sensors
Adding Wired Sensors
Adding a Wired HA-III+Humidity Sensor
D-011-0152
Note A supervised WaterBug sensor must be used
Adding a Wired WaterBug Sensor
Select N.O. Contact or N.C. Contact
Adding a Wired Contact Closure Sensor
D-011-0152
Adding a 4-20mASensor
Configuring the Relays
Monitoring Environmental Conditions
Operation
Viewing Active Alarms
Viewing Sensor Settings
Viewing Pending Alarm Information
Viewing the Alarm Log
Viewing the Event Log
Viewing Limit Settings
Viewing Firmware Information
Viewing the Sensor Log
Operation
D-011-0152
Viewing RF Information
Viewing RF Information
Locking and Unlocking the EA800
Maintenance
Pausing Monitoring and Cancelling Pause
Replacing a Sensor
Adding a Sensor
SENSORS screen
Editing Sensor Parameters
Deleting a Sensor
Reprogramming a Relay
F3 F3
Changing the Time Format
Changing the Date Format
Changing Sensor Data Collection Frequency
Changing the Date or Time Setting
Changing the Buzzer Setting
Changing the Buzzer Setting
Maintenance
Changing the Password
D-011-0152
Clearing the Sensor Log
Clearing the Alarm Log
Clearing the Alarm Log
Maintenance
Updating the Firmware
D-011-0152
F3 LOAD/SAVE CONFIG screen
Saving Configuration Settings
CONFIG screen
Loading Configuration Settings
Exporting the Stored Logs
Exported Alarm Data
Exported Sensor Data
Exported Event Data
12/24/2007 07 06 03 PM
Sensor deleted
D-011-0152
Exporting the Stored Logs
ACTIVE ALARMS screen
Troubleshooting
Viewing Signal Strength for a Wireless Sensor
Verifying RF Signal Strength
Base Unit and Sensor Specifications
Specifications
Accessories
Figure 17. Locked Screen Map
Appendix A Screen Maps
D-011-0152
Figure 18. Unlocked Screen Map - Top Level
Figure 19. Sensors Screen Map
Appendix A Screen Maps
D-011-0152
D-011-0152
Figure 20. Add New Sensor Screen Map
Figure 21. Edit Sensor Screen Map
Appendix A Screen Maps
Figure 22. Relay Screen Map
D-011-0152
D-011-0152
Figure 23. Data Log Screen Map
Figure 24. System Screen Map
Appendix A Screen Maps
D-011-0152
D-011-0152
Figure 25. Configuration Screen Map
Installation
Appendix B Planning Worksheet
Alarm Condition
Appendix B Planning Worksheet
D-011-0152
Appendix
C Wiring Diagram
D-011-0152
Appendix D System Configuration Record
Unit of Measure
Appendix D System Configuration Record
Sensor 6 Settings wireless
Appendix D System Configuration Record
D-011-0152
Warranty and Service Information
Winland Electronics
Manufactured in the U.S.A by
1950 Excel Drive, Mankato, MN, Outside MN Phone
Phone Fax