Enviro EA800 owner manual Appendix, C Wiring Diagram

Page 89
Appendix

D-011-0152

85

Sensor

Wire Color/

 

 

Wire Color/

Alarm Panel

Connection

Designation

 

 

Designation

Connection

 

J6

 

 

NC

 

 

(-)

 

 

 

 

Input 4

Aux

COM

 

 

+

 

 

 

 

NO

 

 

(-)

 

 

 

 

Input 3

 

NC

 

 

+

 

 

 

 

Output 8

COM

 

 

(-)

 

 

 

Input 2

 

NO

 

 

+

 

 

 

 

 

NC

 

 

(-)

 

 

 

 

Input 1

Output 7

COM

 

 

+

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

Output 6

COM

 

 

 

 

 

NO

 

 

 

 

 

NC

 

___

NO

NC

Output 4 COM

NO

NC

Output 3 COM

NO

 

 

 

 

J5

 

 

NC

 

 

 

 

 

Output 2

COM

 

 

 

 

 

 

 

 

 

 

(-)

Aux

 

NO

 

 

 

 

 

 

 

 

 

+

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Out

 

NC

 

 

 

 

(-)

 

 

 

 

 

Power

Output 1

COM

 

 

 

 

 

 

 

 

+

 

 

 

 

In

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

EA800

Output 5

Note:

 

 

Photocopy and complete copy of this diagram for each EA800 to be

Appendix

 

installed in the system.

C: Wiring Diagram

Appendix C: Wiring Diagram

COM

Image 89
Contents D-011-0152 Limitations of the Alarm System or Device Installation Table of ContentsGeneral Information PreparationOperation Overview General InformationHow to Use This Manual D-011-0152 Block DiagramsGeneral Information Symbols on the Product or Manual Labeling D-011-0152 Monitoring ScreensGeneral Information Keys Base Unit Connections Access Control and Passwords selected System Configuration Parameterswill sound when an alarm occurs if DISABLE is Temperature Sensors SensorsTheory of Operation Humidity Sensors4-20mASensors Power Supply / Sensor Voltage Selection Contact Closure Sensors Water SensorsMulti-FunctionSensors Resolution Sensor Parameter DescriptionsMaximum Allowed High Scaled ValueRelay Operation D-011-0152 Relay OperationPreparation D-011-0152 To alarm-on-closed From 11-26VDC power supplyloop circuit power supplied via loop From 11-26VDC power supplyD-011-0152 Power Requirements InstallationTools and Supplies Required Mounting the EA800 Rear PlateInstall the Wireless Sensors Install the Wired SensorsEA800 Base Unit Power Connections SENSOR MODEL NO RESET BUTTONSENSOR MODEL NO RESET BUTTOND-011-0152 J6 Input 1 Input 2 Input 3 InputConnecting Wired HA-III+Humidity Sensors Connecting Wired 4-20mASensors Programming Connecting the EA800 Alarm OutputsConfiguring System Parameter Settings Accessing the MAIN MENU for Programming3.Enter the SYSTEM menu and then select the CONFIGURATION menu as shown below DISABLED is selected Setting the Current Date D-011-0152 Setting the TimeAdding a Wireless Temperature Sensor Adding Wireless SensorsD-011-0152 Adding Wireless SensorsD-011-0152 InstallationD-011-0152 D-011-0152 Adding a Wireless Humidity SensorInstallation D-011-0152 D-011-0152 InstallationD-011-0152 D-011-0152 InstallationSelect N.O. Contact or N.C. Contact D-011-0152 Verify Wireless Signal StrengthAdding a Wired Temperature Sensor Adding Wired SensorsD-011-0152 Adding a Wired HA-III+Humidity SensorAdding Wired Sensors Note A supervised WaterBug sensor must be used Adding a Wired WaterBug SensorD-011-0152 Adding a Wired Contact Closure SensorSelect N.O. Contact or N.C. Contact Adding a 4-20mASensor Configuring the Relays Monitoring Environmental Conditions OperationViewing Active Alarms Viewing Sensor SettingsViewing Pending Alarm Information Viewing the Alarm LogViewing the Event Log Viewing Limit SettingsViewing Firmware Information Viewing the Sensor LogOperation D-011-0152Viewing RF Information Viewing RF InformationLocking and Unlocking the EA800 MaintenancePausing Monitoring and Cancelling Pause Replacing a Sensor Adding a SensorSENSORS screen Editing Sensor ParametersF3 F3 Reprogramming a RelayDeleting a Sensor Changing the Time Format Changing the Date FormatChanging Sensor Data Collection Frequency Changing the Date or Time SettingChanging the Buzzer Setting Changing the Buzzer SettingD-011-0152 Changing the PasswordMaintenance Clearing the Alarm Log Clearing the Alarm LogClearing the Sensor Log D-011-0152 Updating the FirmwareMaintenance F3 LOAD/SAVE CONFIG screen Saving Configuration SettingsCONFIG screen Loading Configuration SettingsExporting the Stored Logs Exported Alarm DataExported Sensor Data Exported Event Data12/24/2007 07 06 03 PM Sensor deletedD-011-0152 Exporting the Stored LogsACTIVE ALARMS screen TroubleshootingViewing Signal Strength for a Wireless Sensor Verifying RF Signal StrengthBase Unit and Sensor Specifications SpecificationsAccessories Figure 17. Locked Screen Map Appendix A Screen MapsD-011-0152 Figure 18. Unlocked Screen Map - Top LevelD-011-0152 Appendix A Screen MapsFigure 19. Sensors Screen Map D-011-0152 Figure 20. Add New Sensor Screen MapFigure 21. Edit Sensor Screen Map Appendix A Screen MapsFigure 22. Relay Screen Map D-011-0152D-011-0152 Figure 23. Data Log Screen MapD-011-0152 Appendix A Screen MapsFigure 24. System Screen Map D-011-0152 Figure 25. Configuration Screen MapInstallation Appendix B Planning WorksheetAlarm Condition Appendix B Planning WorksheetD-011-0152 Appendix C Wiring DiagramD-011-0152 Appendix D System Configuration Record Unit of Measure Appendix D System Configuration Record Sensor 6 Settings wireless Appendix D System Configuration Record D-011-0152 Warranty and Service Information Winland Electronics Manufactured in the U.S.A by1950 Excel Drive, Mankato, MN, Outside MN Phone Phone Fax