Quadra-Fire CB1200I-B owner manual Charred Areas in the Back

Page 23

R

CB1200-I Pellet Insert

G. Optional Log Set Placement Instructions

H. Thermostat Installation

 

 

 

 

 

 

 

 

 

 

 

 

1.

A 12 volt AC thermostat is required to operate this pellet

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

appliance. You may use the included wall mount thermo-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Logs are FRAGILE. Use extreme care when handling or

 

 

 

stat or purchase an optional programmable thermostat

 

 

cleaning logs.

 

 

 

or remote control. The included thermostat is equipped

 

 

 

 

 

 

 

 

 

 

 

 

 

with an adjustable heat anticipator. The current rating is

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Place the front log in first as shown in Figure 23.1. Place

 

.05 amps. The anticipator needs to be adjusted to the

 

 

log between firepot and face of appliance with charred

 

lowest setting available.

 

 

area surrounding firepot.

2.

When mounting a thermostat on a wall, be sure to follow

2. Set the left and right twigs onto the log, placing the holes

 

your thermostat installation instructions carefully.

 

NOTE: Thermostat must be mounted level for accu-

 

 

in the base of twigs over the locating pins in log. See

 

 

 

 

rate readings. The thermostat should be mounted on

 

 

Figure 23.2. Ensure that the charred ends are facing

 

 

 

 

an inside wall and not in direct line with the appliance

 

 

the firepot.

 

 

 

 

convection air. Remove any packaging from inside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the thermostat before using.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: If the thermostat is located too close to the

 

 

 

 

 

 

 

 

 

 

 

 

 

appliance, you may need to set the temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

setting slightly higher to maintain the desired tem-

 

 

 

 

 

 

 

 

 

 

 

 

 

perature in your home.

 

 

 

 

 

 

 

 

 

 

 

 

3.

Open right side plane to access a 4 screw terminal block

 

 

 

 

 

 

 

 

 

 

 

 

 

located on the bottom right hand side next to the power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cord inlet. The center 2 screws are for the thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCATING PINS

 

wires. The outer 2 are the mounting screws for the ter-

 

 

 

 

 

 

minal block. Figure 23.1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution

 

 

 

 

 

 

Shock hazard.

 

Figure 23.1

 

 

 

 

• Do NOT remove grounding prong from plug.

 

 

 

 

 

 

• Plug directly into properly grounded 3 prong

 

 

 

 

 

 

receptacle.

 

 

 

 

 

 

 

Charred Areas in the Back

 

 

 

• Route cord away from appliance.

 

 

 

 

 

• Do NOT route cord under or in front of appli-

 

 

 

 

 

 

 

 

 

 

 

 

ance.

 

 

 

 

 

 

 

Left Twig

Right Twig

 

 

 

Terminal Block

Front Log

 

Center 2 Screws for

 

 

Thermostat Wires

Figure 23.2

 

 

NOTE:

 

Power Outlet

Due to the abrasive nature of a pellet appliance fire, the

 

logs are not covered under warranty. Any placement vari-

 

ation other than shown here can cause excessive heat

 

and shall void the appliance warranty.

Figure 23.3

 

October 26, 2006

7014-083C

Page 23

Image 23
Contents CB1200I-B CB1200-I Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Listing and Code Approvals Appliance Location Design, Installation & Location ConsiderationsFire Safety Getting StartedInspect Appliance & Components and Pre-Use Check List CB1200-I Pellet Insert Tools And Supplies NeededMeasuring Standards Appliance Dimensions Dimensions and ClearancesInch 0mm Clearance to Exposed Section and Face Trim Shown with Rear Vent and Optional Outside AirFace Trim Calculating Alternate Floor Protection Material CB1200-I Pellet Insert Masonry Minimum OpeningFloor Protection Starter hole Mark area of floor to cut Vent manufacturer Install vent at clearances specified byVent Information Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCB1200-I Pellet Insert Equivalent Feet of Pipe Venting Systems CB1200-I Pellet Insert Full Reline With Outside Air Lation in a mobile home Mobile Home InstallationYou must use a Quadra-Fire Outside Air Kit for instal Appliance Set-Up Rear Shroud InstallationFor Top Vent Installation Rear Vent Installation PreparationInstalling Rear Shroud Attaching Shroud to Hopper Body CB1200-I Pellet Insert Outside Air Kit Instructions Adjustable Hopper OptionsOptional Grille Installation To adjust hopperSize 9d x 45w, 2 to 10 Height Adjustment CB1200-I Pellet Insert Adjustable Hearth SupportCB1200-I Pellet Insert Panel and Trim Set Completed View CB1200-I Pellet Insert Panel and Trim Set Cont’dCharred Areas in the Back Fuel Size And Material General Operating Information Operating InstructionsCB1200-I Pellet Insert Before Your First Fire Fuel Adjustment Control RodFire Characteristics Feed Rate Adjustment InstructionsDo not Leave Firepot Floor Open Frequently Asked QuestionsPossible Cause Corrective Action TroubleshootingSymptom Page Page Pellet Insert CB10Maintaining & Servicing Your ApplianceCleaning the Glass Frequency As needed Cleaning Heat Exchanger ChambersCleaning Beneath Heat Exchanger Cleaning Exhaust PathHigh Ash Fuel Content Maintenance Igniter Replacement Ered Phillips head screw driver to remove Screws Top frame when removing and replacing center GlassReplacing Center Glass Replacing Side GlassComponent Function Reference MaterialsSnap Disc #2 Fuel Delivery Interrupt 200F Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 125FGlass Size Center 13-7/8 wide x 11 high Glass Size Sides CB1200-I Pellet Insert Component LocationsExploded Views Beginning Manufacture Date April 8Beg. Manufacture Date July Item # Part Descsription, Alphabetical Order CB1200-I Pellet Insert Service Parts and AccessoriesNbr Description 7014-083C October 26 Appliance Item No AccessoriesDate of Service Performed By Description of Service CB1200-I Pellet Insert Service And Maintenance LogCB1200-I Pellet Insert Warranty Policy Lifetime WarrantyTelephone CB1200-I Pellet Insert