Quadra-Fire CB1200I-B owner manual Appliance Set-Up, Rear Shroud Installation

Page 17

 

R

CB1200-I Pellet Insert

 

 

 

 

 

 

7

Appliance Set-Up

 

 

 

A.Rear Shroud Installation

1.Top Vent Installations

Parts Required:

Part 811-0680, Rear Shroud Kit.

Includes: Six galvanized steel shroud pieces, two cover plates and fastener package.

Part 811-0650, Rear Shroud Top Vent

Includes: Vent pipe and two 1/4 - 20 x 3/4" bolts with nuts.

Part 811-0660, 3" Top Vent Adapter or Part 811-0670, 4” Top Vent Adapter

2.Rear vent installations Parts Required:

Part 811-0680, Rear Shroud Kit. Part 811-0690, Rear Vent Kit

Includes: Rear Vent Adapter and fastener package.

 

 

 

 

 

REAR SHROUD TOP

 

 

 

 

VENT PART 811-0650

 

 

 

 

 

 

Right Corner

Top Vent Opening

Left Corner

 

 

 

 

 

 

 

Left

Corner

 

 

Piece

 

Filler

 

 

 

-Out

Rear

Knock

Access

Vent

 

 

 

 

 

 

Outside

Air

Vent

 

 

 

 

 

Pipe

Access

 

 

 

 

 

Tools Required:

Electric drill, 1/8" drill bit, Phillips screw driver, 3/8" wrench & 7/16" wrench, (7/16" socket wrench & high temperature silicone adhesive are also required for rear vent installations).

Figure 17.1

Complete the following procedures, based on your venting installation, prior to installing the rear shroud kit. (Note: All photos depict top vent installation).

Top Vent Installation Preparation

Filler Piece

Figure 17.2

Rear Shroud

Top Vent

Figure 17.3

1.Remove the top vent adapter from the vertical exhaust transition pipe. Figures 17.2 and 17.5.

2.Use 2 screws to attach left corner filler piece of rear shroud to the insert hopper. Figures 17.1 and 17.2.

3.Use (2) 1/4 - 20 x 3/4" bolts with nuts to install rear shroud top vent to the exhaust transition. See boxed area in Figure 17.3. (Circled area, top vent adapter, will be installed later).

4.Install the left shroud panel corner at 3 points, 2 screws into back of hopper and 1 down into the filler piece).

Figure 17.4

Left Corner

Piece

Figure 17.4

Vertical Exhaust

Transition Pipe

Top Vent Adapter

Figure 17.5

October 26, 2006

7014-083C

Page 17

Image 17
Contents CB1200I-B CB1200-I Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Listing and Code Approvals Fire Safety Design, Installation & Location ConsiderationsGetting Started Appliance LocationInspect Appliance & Components and Pre-Use Check List CB1200-I Pellet Insert Tools And Supplies NeededMeasuring Standards Appliance Dimensions Dimensions and ClearancesInch 0mm Clearance to Exposed Section and Face Trim Shown with Rear Vent and Optional Outside AirFace Trim Calculating Alternate Floor Protection Material CB1200-I Pellet Insert Masonry Minimum OpeningFloor Protection Starter hole Mark area of floor to cut Vent manufacturer Install vent at clearances specified byVent Information Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCB1200-I Pellet Insert Equivalent Feet of Pipe Venting Systems CB1200-I Pellet Insert Full Reline With Outside Air Lation in a mobile home Mobile Home InstallationYou must use a Quadra-Fire Outside Air Kit for instal Appliance Set-Up Rear Shroud InstallationFor Top Vent Installation Rear Vent Installation PreparationInstalling Rear Shroud Attaching Shroud to Hopper Body Optional Grille Installation Adjustable Hopper OptionsTo adjust hopper CB1200-I Pellet Insert Outside Air Kit InstructionsSize 9d x 45w, 2 to 10 Height Adjustment CB1200-I Pellet Insert Adjustable Hearth SupportCB1200-I Pellet Insert Panel and Trim Set Completed View CB1200-I Pellet Insert Panel and Trim Set Cont’dCharred Areas in the Back Fuel Size And Material General Operating Information Operating InstructionsFire Characteristics Fuel Adjustment Control RodFeed Rate Adjustment Instructions CB1200-I Pellet Insert Before Your First FireDo not Leave Firepot Floor Open Frequently Asked QuestionsPossible Cause Corrective Action TroubleshootingSymptom Page Page Pellet Insert CB10Maintaining & Servicing Your ApplianceCleaning Beneath Heat Exchanger Cleaning Heat Exchanger ChambersCleaning Exhaust Path Cleaning the Glass Frequency As neededHigh Ash Fuel Content Maintenance Igniter Replacement Replacing Center Glass Top frame when removing and replacing center GlassReplacing Side Glass Ered Phillips head screw driver to remove ScrewsComponent Function Reference MaterialsWiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 125F Snap Disc #2 Fuel Delivery Interrupt 200FExploded Views CB1200-I Pellet Insert Component LocationsBeginning Manufacture Date April 8 Glass Size Center 13-7/8 wide x 11 high Glass Size SidesBeg. Manufacture Date July Item # Part Descsription, Alphabetical Order CB1200-I Pellet Insert Service Parts and AccessoriesNbr Description 7014-083C October 26 Appliance Item No AccessoriesDate of Service Performed By Description of Service CB1200-I Pellet Insert Service And Maintenance LogCB1200-I Pellet Insert Warranty Policy Lifetime WarrantyTelephone CB1200-I Pellet Insert