Quadra-Fire CB1200I-B owner manual

Page 29

R

CB1200-I Pellet Insert

Symptom

Possible Cause

Corrective Action

Convection blower fails to

No call light.

Defective control box.

start.

#1 snap disc defective.

Replace snap disc.

 

 

Blower not plugged in.

Check that blower is plugged into wire har-

 

 

ness.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Exhaust blower fails to

Blower not plugged in.

Check that blower is plugged into wire har-

start or does not shut off.

 

ness.

 

Blower is clogged with ash.

Clean exhaust system.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Large, lazy flame, orange

Dirty appliance.

Clean appliance, including firepot, heat

color. Black ash on glass.

Poor fuel quality, high ash content.

exchangers and venting system. Remove

 

 

stainless steel baffle from firebox to clean

 

 

ash from on top of baffle. Clean behind rear

 

 

brick panels. Change fuel brand to pre-

 

Firepot clean-out plate not completely

mium.

 

 

 

closed.

Check that firepot clean-out plate is fully

 

 

closed.

 

Excessive amount of fuel.

Reduce feed rate using feed rate adjustment

 

 

control rod located inside hopper.

Nuisance shutdowns.

Low flame.

Increase feed by opening feed rate adjust-

 

 

ment control rod located inside hopper.

 

Sawdust buildup in hopper.

Clean hopper, see page 32.

 

Feed motor is reversing.

Check for good connections between feed

 

 

motor and wire harness.

 

Defective thermocouple.

Replace thermocouple.

 

Defective control box.

Replace control box.

 

Firepot more than 1/2 full

See pages 32 & 33 for detailed instructions

 

 

for “High Ash Fuel Content Maintenance”.

Appliance calls for heat.

Thermocouple is defective or not properly

Check connections on thermocouple or

Call light illuminates.

plugged in.

replace if defective.

Exhaust blower starts.

 

A flashing yellow light on the control box

No feed or igniter.

 

indicates a problem with the thermocouple.

 

Defective control box

Replace control box.

October 26, 2006

7014-083C

Page 29

Image 29
Contents CB1200I-B CB1200-I Pellet Insert Welcome to the Quadra-Fire FamilyTable of Contents Listing and Code Approvals Fire Safety Design, Installation & Location ConsiderationsGetting Started Appliance LocationInspect Appliance & Components and Pre-Use Check List CB1200-I Pellet Insert Tools And Supplies NeededMeasuring Standards Appliance Dimensions Dimensions and ClearancesInch 0mm Clearance to Exposed Section and Face Trim Shown with Rear Vent and Optional Outside AirFace Trim Calculating Alternate Floor Protection Material CB1200-I Pellet Insert Masonry Minimum OpeningFloor Protection Starter hole Mark area of floor to cut Vent manufacturer Install vent at clearances specified byVent Information Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCB1200-I Pellet Insert Equivalent Feet of Pipe Venting Systems CB1200-I Pellet Insert Full Reline With Outside Air Lation in a mobile home Mobile Home InstallationYou must use a Quadra-Fire Outside Air Kit for instal Appliance Set-Up Rear Shroud InstallationFor Top Vent Installation Rear Vent Installation PreparationInstalling Rear Shroud Attaching Shroud to Hopper Body Optional Grille Installation Adjustable Hopper OptionsTo adjust hopper CB1200-I Pellet Insert Outside Air Kit InstructionsSize 9d x 45w, 2 to 10 Height Adjustment CB1200-I Pellet Insert Adjustable Hearth SupportCB1200-I Pellet Insert Panel and Trim Set Completed View CB1200-I Pellet Insert Panel and Trim Set Cont’dCharred Areas in the Back Fuel Size And Material General Operating Information Operating InstructionsFire Characteristics Fuel Adjustment Control RodFeed Rate Adjustment Instructions CB1200-I Pellet Insert Before Your First FireDo not Leave Firepot Floor Open Frequently Asked QuestionsPossible Cause Corrective Action TroubleshootingSymptom Page Page Pellet Insert CB10Maintaining & Servicing Your ApplianceCleaning Beneath Heat Exchanger Cleaning Heat Exchanger ChambersCleaning Exhaust Path Cleaning the Glass Frequency As neededHigh Ash Fuel Content Maintenance Igniter Replacement Replacing Center Glass Top frame when removing and replacing center GlassReplacing Side Glass Ered Phillips head screw driver to remove ScrewsComponent Function Reference MaterialsWiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 125F Snap Disc #2 Fuel Delivery Interrupt 200FExploded Views CB1200-I Pellet Insert Component LocationsBeginning Manufacture Date April 8 Glass Size Center 13-7/8 wide x 11 high Glass Size SidesBeg. Manufacture Date July Item # Part Descsription, Alphabetical Order CB1200-I Pellet Insert Service Parts and AccessoriesNbr Description 7014-083C October 26 Appliance Item No AccessoriesDate of Service Performed By Description of Service CB1200-I Pellet Insert Service And Maintenance LogCB1200-I Pellet Insert Warranty Policy Lifetime WarrantyTelephone CB1200-I Pellet Insert