Quadra-Fire QV36-A, QV32-A manual Venting with Two 90 Elbows

Page 19

V

H

H + H1

1' MIN. (305 mm)

2' MAX. (610 mm)

4' MAX. (1.22m)

2' MIN. (610 mm)

4' MAX. (1.22 m)

8' MAX. (2.4m)

3' MIN. (914 mm)

6' MAX. (1.86 m)

12' MAX. (3.6m)

4' MIN. (1.22 m)

8' MAX. (2.48 m)

16' MAX. (4.8m)

V+H+H1 = 40' MAX. (12.4 m) H = 8' MAX. (2.48 m)

H+H1 = 16' MAX. (4.8m)

H1

V

Use D-Series

components only.

H

V (FT)

H + H1 (FT)

1' MIN. (305 mm)

2' MAX. (610 mm)

2' MIN. (610 mm)

4' MAX. (1.22 m)

3' MIN. (914 mm)

6' MAX. (1.86 m)

4' MIN. (1.22 m)

8' MAX. (2.48 m)

 

H + H1= 8' MAX. (2.48 m)

V + H + H1= 40' (12.2m) MAX.

Note: There MUST be a 25% reduction in total H when using flex vent, except when using the simple up and out installation (see Figure 9).

V

H

H1

Figure 14. Venting with Two 90° Elbows

19

Image 19
Contents What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents Service Parts Standing Pilot Ignition / D’ALLUMAGE PAR Veilleuse Accessories / AccessoiresLog Set Assembly DF-36TS-BK Certification Installation CodesHigh Altitude Installations Appliance CertificationIntroducing the Village Collection Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the QV36-A Diagram of the QV-32-A Locating the Fireplace Constructing the Fireplace ChaseClearance Requirements Framing the Fireplace Framing DimensionsDV-FLEX-10 47 3/4 Identifying Vent Components Installing the Vent SystemVent System Approvals Use SL D-Series components only Straight UP Vertical VentingUse D-Series components only Use SL D-Series components only Venting with Two 90 Elbows Natural GAS MAX. = 16 FT 4.8m V + V1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H Venting with Four 90 elbows SET of Collars YOU are Using could Cause a Fire Continue Adding Vent Components Adding Venting Components Install Support BracketsCeiling Firestop Ceiling Side Minimum Trapezoid CAP Termination Vent TerminationPositioned SO That the Arrow is Pointing UP 191mmVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Gas Control System Positioning, Leveling, and Securing the FireplaceStanding Pilot Ignition System Pressure Gas Supply LineGas Pressure Requirements To Check for GAS LeaksWall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesFinishing Refractory Kit Placement BRICK-291, BRICK-293Glass Specifications Installing Trim, Logs Ember MaterialBefore Lighting the Fireplace Double-check for faulty componentsWhat to do if YOU Smell GAS After the InstallationLighting the Appliance Standing Pilot IgnitionImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace MaintenanceTroubleshooting Be Placed in this Opening Lifetime Warranty