Quadra-Fire QV32-A, QV36-A manual Installing Trim, Logs Ember Material, Glass Specifications

Page 36

Figure 43

Position the right wall all the way to back wall. Secure in position as was done in Step 2 (see Figure 44).

Figure 44

Replace the logs referring to your manual and log instruc- tions.

Step 10. Installing Trim, Logs and

Ember Material

Installing the Trim

Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F. (149° C) minimum sealant.

WARNING: WHEN FINISHING THE FIREPLACE,

!NEVER OBSTRUCT OR MODIFY THE AIR INLET/ OUTLET GRILLES IN ANY MANNER.

Install optional marble and brass trim surround kits as desired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover up the gap between the sheet rock and the fireplace.

Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be opened and the trim door removed.

Positioning the Logs

If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the instructions that accompany the logs. Save the log instructions with this manual.

If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement.

Shutter Settings

 

 

Model

NG

LP

QV32-A

3/16”

SET

QV36-A

1/4”

SET

Placing the Ember Material

Ember material is shipped with this gas fireplace. The bag labeled Mystic Embers is standard glowing ember material. To place the ember material:

Remove the top louver by lifting it up and away from the unit.

Unlatch the latches at the top and bottom of the glass door.

Remove the glass door from the unit (see Figure 45).

Place dime size pieces of ember material about 1/2 inch apart near port holes in burner top. Do NOT press em- bers into burner ports. Cover the top of the burner with a single layer of ember material (see Figure 46).

Save the remaining ember materials for use during fire- place servicing. The bag of embers provided is sufficient for 3 to 5 applications.

Reinstall and latch the glass door and top louver on the unit.

CAUTION: THE GLASS DOOR MUST BE SECURELY LATCHED BEFORE OPERATING THE UNIT.

LATCHES

(BOTH TOP

AND BOTTOM)

GLASS

ASSEMBLY

Figure 45. Glass Assembly

 

GLASS SPECIFICATIONS:

 

QV36-A

24 5/8 x 35 3/8

CERAMIC

QV32-A

21 1/8 x 30 3/8

CERAMIC

EMBER MATERIALS

Figure 46. Placement of the Ember Material

36

Image 36
Contents Installers Guide What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Accessories / Accessoires Standing Pilot Ignition / D’ALLUMAGE PAR VeilleuseLog Set Assembly DF-36TS-BK Installation Codes High Altitude InstallationsAppliance Certification CertificationPre-install Preparation Introducing the Village Collection Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the QV36-A Diagram of the QV-32-A Constructing the Fireplace Chase Locating the FireplaceClearance Requirements Framing Dimensions Framing the FireplaceDV-FLEX-10 47 3/4 Installing the Vent System Identifying Vent ComponentsVent System Approvals Straight UP Vertical Venting Use SL D-Series components onlyUse D-Series components only Use SL D-Series components only Venting with Two 90 Elbows Natural GAS MAX. = 16 FT 4.8m V + V1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H Venting with Four 90 elbows SET of Collars YOU are Using could Cause a Fire Adding Venting Components Install Support Brackets Continue Adding Vent ComponentsCeiling Firestop Ceiling Side Vent Termination Positioned SO That the Arrow is Pointing UP191mm Minimum Trapezoid CAP TerminationVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Fireplace Gas Control SystemStanding Pilot Ignition System Gas Supply Line Gas Pressure RequirementsTo Check for GAS Leaks PressureWiring the Fireplace For Standing Pilot Ignition Wiring Appliance RequirementsOptional Accessories Wall SwitchRefractory Kit Placement BRICK-291, BRICK-293 FinishingInstalling Trim, Logs Ember Material Glass SpecificationsDouble-check for faulty components Before Lighting the FireplaceAfter the Installation Lighting the ApplianceStanding Pilot Ignition What to do if YOU Smell GASFireplace Maintenance Important Turn OFF the GAS Before Servicing Your FireplaceTroubleshooting Be Placed in this Opening Lifetime Warranty