Quadra-Fire QV36-A, QV32-A manual Table of Contents

Page 3

TABLE OF CONTENTS

 

Safety and Warning Information

2

uService Parts Lists

4

Section 1: Approvals and Codes

8

Appliance Certification

8

Installation Codes

8

High Altitude Installations

8

Section 2: Getting Started

9

Introducing the Village Collection Gas Fireplaces

9

u Pre-installation Preparation

9

Section 3: Installing the Fireplace

12

Constructing the Fireplace Chase

12

u Step 1

Locating the Fireplace

12

Step 2

Framing the Fireplace

13

Step 3

Installing the Vent System

16

 

A. Vent System Approvals

16

 

B. Installing Vent Components

26

 

u C. Vent Termination

29

Step 4

Positioning, Leveling, and

 

 

Securing the Fireplace

32

Step 5

The Gas Control Systems

32

Step 6

The Gas Supply Line

33

Step 7

Gas Pressure Requirements

33

Step 8

Wiring the Fireplace

34

Step 9

Finishing

35

 

Refractory Kit Placement

35

Step 10

Installing Trim, Logs, and Ember Material

36

 

Installing the Trim

36

 

Shutter Settings

36

 

Placing the Ember Material

36

Step 11

Before Lighting the Fireplace

37

Step 12

Lighting the Appliance

38

After the Installation

38

Section 4: Maintaining and Servicing Your Fireplace

39

Section 5: Troubleshooting

40

Limited Lifetime Warranty

42

u = Contains updated information.

 

3

Image 3
Contents What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents Service Parts Standing Pilot Ignition / D’ALLUMAGE PAR Veilleuse Accessories / AccessoiresLog Set Assembly DF-36TS-BK Certification Installation CodesHigh Altitude Installations Appliance CertificationPre-install Preparation Introducing the Village Collection Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the QV36-A Diagram of the QV-32-A Constructing the Fireplace Chase Locating the FireplaceClearance Requirements Framing the Fireplace Framing DimensionsDV-FLEX-10 47 3/4 Installing the Vent System Identifying Vent ComponentsVent System Approvals Straight UP Vertical Venting Use SL D-Series components onlyUse D-Series components only Use SL D-Series components only Venting with Two 90 Elbows Natural GAS MAX. = 16 FT 4.8m V + V1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H Venting with Four 90 elbows SET of Collars YOU are Using could Cause a Fire Continue Adding Vent Components Adding Venting Components Install Support BracketsCeiling Firestop Ceiling Side Minimum Trapezoid CAP Termination Vent TerminationPositioned SO That the Arrow is Pointing UP 191mmVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Fireplace Gas Control SystemStanding Pilot Ignition System Pressure Gas Supply LineGas Pressure Requirements To Check for GAS LeaksWall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesFinishing Refractory Kit Placement BRICK-291, BRICK-293Glass Specifications Installing Trim, Logs Ember MaterialBefore Lighting the Fireplace Double-check for faulty componentsWhat to do if YOU Smell GAS After the InstallationLighting the Appliance Standing Pilot IgnitionImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace MaintenanceTroubleshooting Be Placed in this Opening Lifetime Warranty