K. After Appliance is Lit

Initial Break-in Procedure

The appliance should be run three to four hours continuously on high.

Turn the appliance off and allow it to completely cool.

Remove fixed glass assembly. See Section 12.H.

Clean fixed glass assembly. See Section 3.

Replace the fi xed glass assembly and run continuously on high an additional 9 hours.

This cures the materials used to manufacture the fire- place.

NOTICE! Open windows for air circulation during ap- pliance break-in.

Some people may be sensitive to smoke and odors.

Smoke detectors may activate.

L.Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

Blue flames

This is a result of normal operation and the fl ames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

 

 

When first operated, this appliance may release an odor for the first several hours. This is caused

Odor from appliance

by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may

 

also be released from finishing materials and adhesives used around the appliance.

 

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

Film on the glass

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

 

process. A non-abrasive cleaner such as gas fi replace glass cleaner may be necessary. See

 

your dealer.

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the appliance.

Is it normal to see the pilot flame burn

In an intermittent pilot ignition system (IPI), the pilot fl ame should turn off when appliance is

turned off. Some optional control systems available with IPI models may allow pilot flame to

continually?

remain lit.

 

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

11

Image 11
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetControl Module Operation GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed QFI35 QFI30 Fireplace Size RequirementsMinimum Fireplace Opening Minimum Fireplace SizeSide View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsIPI Models Placing, Securing and Leveling the Appli- anceDamper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire Plus Ignition System Wiring ON/OFF SwitchBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 QFI30 QFI35 Air Shutter SettingAir Shutter Settings IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramModel Dimensions Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information