Quadra-Fire QF130 Installing Adaptor and Termination Cap, Masonry, Factory Built Wood Burning

Page 23

F. Installing Adaptor and Termination Cap

For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) .

To install adaptor see Figure 8.5.

CAUTION! Risk of Cuts/Abrasions/Flying Debris.

Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Damper Flashing Kit (Optional)

For use with LINK-DV30B or LINK-DV4-30B Liner Kit.

2FT.

MIN.

GAS DIRECT VENT

TERMINATION CAP

 

 

 

 

HORIZONTAL

 

 

 

 

20 INCHES MIN.

 

 

OVERHANG

 

 

 

VERTICAL

 

 

LOWEST

 

 

WALL

 

 

 

DISCHARGE

 

 

 

OPENING

 

 

 

X

12

ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

Note: Damper may have to be removed to use this kit.

Run fl ex liners through 3 in. holes in damper fl ashing.

Attach damper flashing to fi rebox roof with self tapping screws included in kit.

CLASS A PIPE

Roof Pitch

H (Min.) Ft.

Flat to 6/12

....................

1.0*

Over 6/12 to 7/12

1.25*

Over 7/12 to 8/12

1.5*

Over 8/12 to 9/12

2.0*

Over 9/12 to 10/12

2.5*

Over 10/12 to 11/12

3.25

Roof Pitch

H (Min.) Ft.

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

* 3 foot minimum in snow regions

Figure 8.4 Minimum Height from Roof to Lowest Discharge Opening

Figure 8.5

To prevent odors and cold drafts, the chimney must be sealed around the vent with non-combustible blanket insulation or fi eld fabricated metal plates.

Note: The LINK-DV4-30B

system REQUIRES this insulation.

Masonry

LINK-DV30B

LINK-DV4-30B

Installation

Installation

Factory Built

Wood Burning

 

TERMINATION

 

CAP

EXHAUST

EXHAUST

AIR

AIR

VENT PIPE

VENT PIPE

 

OR

 

INLET AIR

 

VENT PIPE

Figure 8.6

 

WARNING:

DO NOT BLOCK

THIS PIPE END!

Note: Untwist the pipe while extend- ing it, to achieve full 30’ length.

INLET AIR

VENT PIPE

OPTIONAL LINK-ZC-ADPB

FOR USE WITH CLASS A

WOODBURNING PIPE

Remove 18 inch x 18 inch fl ashing on cap by removing 3 screws. Connect both the LINK-ZC-ADPB to Class A Pipe and the termination cap to the LINK-ZC-ADPB with the self tapping screws provided.

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

23

Image 23
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetControl Module Operation GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed QFI35 QFI30 Fireplace Size RequirementsMinimum Fireplace Opening Minimum Fireplace SizeSide View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsIPI Models Placing, Securing and Leveling the Appli- anceDamper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire Plus Ignition System Wiring ON/OFF SwitchBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 QFI30 QFI35 Air Shutter SettingAir Shutter Settings IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramModel Dimensions Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information