Quadra-Fire QF130 Fireplace Size Requirements, Minimum Fireplace Opening, Minimum Fireplace Size

Page 17

5 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.1. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements.

Any smoke shelves, shields and baffles may be removed

from the factory built fi rebox if attached with mechanical fasteners.

The metal floor of the solid fuel firebox may be removed to facilitate the installation of the insert. The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace must be provided between the insert and the floor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffles and dampers.

Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above.

TOP VIEW

 

FRONT VIEW

 

 

C

A

 

 

G

E

I

 

 

H

 

 

B

 

 

D

SIDE VIEW

F

MINIMUM FIREPLACE SIZE

 

Location

QFI35

 

 

QFI30

 

 

 

 

 

 

 

 

Inches

 

Millimeters

Inches

 

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

A

Rear Width

23-1/2

 

597

20-1/4

 

514

 

 

 

 

 

 

 

 

B

Front Width

34-5/8

 

879

30-1/2

 

775

 

 

 

 

 

 

 

 

C

Glass Opening Width

31-9/16

 

802

27-7/16

 

697

 

 

 

 

 

 

 

 

D

Glass Opening Height

15-11/16

 

398

12-13/16

 

325

 

 

 

 

 

 

 

 

E

Height-Front

24

 

610

20-1/2

 

521

 

 

 

 

 

 

 

 

F

Height-Rear

21-1/16

 

535

17-5/8

 

448

 

 

 

 

 

 

 

 

G**

Unit Depth

16

 

406

14-3/4

 

375

 

 

 

 

 

 

 

 

H

Venting Depth

10-1/2

 

267

9-1/2

 

241

 

 

 

 

 

 

 

 

I

Height to Top of

22

 

559

18-1/4

 

464

Glass Frame

 

 

 

 

 

 

 

 

 

*Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

replace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).

Figure 5.1 Fireplace Opening

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

17

Image 17
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceBefore Lighting Fireplace Module ResetControl Module Operation Final inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size QFI35 QFI30Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsIPI Models Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 QFI30 QFI35 Air Shutter SettingAir Shutter Settings IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramModel Dimensions Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information