C. Optional Accessories Requirements
•This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
•To connect optional accessories, the supplied cord as- sembly should be used. See Figure 10.2 for a wiring diagram for a blower or remote.
Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.
•Plug the cord into a convenient outlet.
•Must use cord supplied.
•An IntelliFire Plus™ Wireless Controls or
•A standard ON/OFF switch is compatible.
WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
BLOWER | PLUG |
120V EXISTING | |
NOTE: IF ANY OF THE ORIGINAL | OUTLET |
WIRE AS SUPPLIED WITH THE |
|
APPLIANCE MUST BE REPLACED, |
|
IT MUST BE REPLACED WITH TYPE |
|
1050 C RATED WIRE. |
|
NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES).
| JUMPER WIRE |
| TEMPERATURE |
| SENSOR SWITCH |
| TO VALVE |
WHT (2) | ORG |
BLK | |
GRN (2) |
|
BLK (2) |
|
VARIABLE SPEED
CONTROL
BLK
BLK BLK
BLK
TEMPERATURE
SENSOR SWITCH
BLK (2)
GRN (2)
BLK (2)
PLUG INTO 120V
EXISTING OUTLET
DC REGULATOR
RECEPTACLE
BLOWER
RECEPTACLE
GRN | SPEED CONTROL |
| (RHEOSTAT) |
BRN | TO VALVE BRACKET |
BLK | (GROUND) |
RED |
|
WHT BLK
GRN GRN
BLK BLK
BLOWERS
BLK BLK
GRN GRN
WHT BLK
Figure 10.2 Fan Wiring Diagram