Quadra-Fire QF130 owner manual Getting Started, Typical Appliance System

Page 15

4 Getting Started

Installer Guide

 

A. Typical Appliance System

NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual

VERTICAL TERMINATION CAP

(SECTION 8.F)

VENT PIPE

(SECTION 8)

3 INCH FLEX LINERS

(SECTION 8)

MANTEL AND MANTEL LEG

SECTION 5.B AND 11.A

SURROUND OR FRONT

NOT SHOWN

SECTION 2.D AND 8.D.

HEARTH EXTENSION

GAS LINE (SECTION 9)

ACCESS THROUGH EXISTING

MASONRY OR WOODBURNING

FIREPLACE

Figure 4.1 Typical System

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

15

Image 15
Contents Models What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationModule Reset Control Module OperationBefore Lighting Fireplace GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components QFI35 QFI30 Fireplace Size RequirementsMinimum Fireplace Opening Minimum Fireplace SizeSide View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsIPI Models Placing, Securing and Leveling the Appli- anceDamper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire Plus Ignition System Wiring ON/OFF SwitchBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 Air Shutter Setting Air Shutter SettingsQFI30 QFI35 Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Appliance Dimension Diagram Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information