8 Installing Vent Pipe and Appliance

A. Vent Limits

The abbreviations listed in this vent table key are used in the vent diagrams.

B. Venting Components

CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Description

Minimum Vertical Run Length 10 ft.

Maximum Vertical Run Length 50 ft.

Horizontal venting is NOT allowed.

Vertical terminations are measured to top of chimney.

This appliance is listed for use with LINK-DV systems and components only. It is permissible to extend venting above existing chimney (within specifi ed maximum verti- cal limits) using SL-D series or Dura Vent GS series 4 in. x 6-5/8 in. gas direct-vent pipe. Connection is made us-

Îing DV-46DVA-GK. The vent must be terminated with the cap supplied with the LINK-series vent kit.

WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION! ALL vent specifications MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.

The vertical vent termination system installed on this model includes:

Flexible vent pipe for exhaust air (included with vent kit).

One length of 3-inch fl exible vent pipe for combustion air (included with vent kit).

One pipe-to-cap adaptor (included with vent kit).

One vertical termination cap (included with vent kit).

C. Connecting Vent Pipe

Reference instructions in the termination kit.

Install the 3-inch fl exible vent pipe(s) down through the chimney.

Secure the exhaust flexible vent pipe to the exhaust starting collar on top of the appliance with three screws and seal with stove cement rated for continuous exposure to 1200ºF or higher. See Figure 8.1.

Use 3 screws to attach the section of inlet air vent to the inlet collar on the collar slide plate and seal with stove cement rated for continuous exposure to 1200ºF or higher. See Figure 8.1. NOTE: The collar slide plate may be removed from appliance to aid installation.

 

TERMINATION

 

ADAPTER

CAP

 

 

 

 

INLET

 

 

COLLAR

 

 

EXHAUST

 

 

COLLAR

 

 

 

INLET AIR STARTING COLLAR

 

EXHAUST

LOCKING TAB

 

AIR

 

 

V = 10 FT. MINIMUM

VENT PIPE

 

 

 

50 FT. MAXIMUM

 

 

 

 

STARTING COLLAR BRACKET

HANDLE

 

 

 

 

EXHAUST STARTING COLLAR

 

INLET AIR

 

 

VENT PIPE

 

 

INLET AIR STARTING COLLAR

 

 

 

NOTE: TO ACHIEVE OPTIMUM PERFOR-

 

 

MANCE OF INSERT, MINIMIZE OR AVOID

 

STARTING COLLAR BRACKET

BENDS IN EXHAUST VENT PIPE.

 

 

Figure 8.1

EXHAUST STARTING COLLAR

 

 

 

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

21

Image 21
Contents Models What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceModule Reset Control Module OperationBefore Lighting Fireplace Final inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size QFI35 QFI30Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsIPI Models Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 Air Shutter Setting Air Shutter SettingsQFI30 QFI35 Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Appliance Dimension Diagram Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information