Quadra-Fire QF130 owner manual Placing, Securing and Leveling the Appli- ance, IPI Models

Page 22

CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

Figure 8.2

Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2).

Place 3/8 inch bead of 300º F silicone on fl ue tile top.

D.Placing, Securing and Leveling the Appli- ance

Install insert (without surround attached) into existing fi replace while pulling collar slide plate forward.

Install gas line into hole provided on insert side.

If applicable install remote control wires into insert side (see Section 8.E).

Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 8.1) and secure with #8 screw.

Level the appliance from side to side and front to back. If necessary, use the leveling legs included with the manual bag to set each corner of the base.

Position any excess flexible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten.

Install fiberglass insulation pieces to back face of surround.

Attach surround. Follow instructions for surround installation included with the front.

Push insert into the opening so that it tightly overlaps the fi replace opening.

WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte- gral grills on solid fuel burning fireplaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.

WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING! Risk of Explosion/Combustion Fumes! Connect vent sections per installation instructions.

Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.

Connect inlet air vent ONLY to inlet air collar on appliance and the termination cap inlet air collar.

DO NOT allow vent to sag below connection point to appliance.

E. Remote Control

IPI Models:

If a remote control kit is used to control blower function, the Auxiliary 300 module can only be placed in the control cavity to the right of the control panel. See Figure 8.3.

AUXILIARY 300 MODULE

Figure 8.3 Location of AUX300 for Remote Control Blower Function - IPI

22

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

Image 22
Contents What to do if you smell gas ModelsHOT Surfaces Homeowner Reference Information CongratulationsXxxxxxxx Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceControl Module Operation Module ResetBefore Lighting Fireplace What to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Appliance is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening QFI35 QFI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance IPI ModelsFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionON/OFF Switch Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationOptional Accessories Requirements BLKFan Wiring with Remote AUX 300 Module FAN WHT GRN BLK BlowersFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Log Set Assembly LOGS-QFI30 Models QFI30 Install the Log AssemblyFor LOG #6 Mates With Slot Mate Notch With Grate BARSlot Log Set Assembly LOGS-QFI35 Models QFI35 Install Back RefractorySlot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 Air Shutter Settings Air Shutter SettingQFI30 QFI35 Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Model Dimensions Appliance Dimension DiagramReference Materials Vent Kits Components Direct Vent Flex Liner KitsContact Information