G. Install the Log Assembly

Log Set Assembly: LOGS-QFI30

Models: QFI30

SRV2227-702

SRV2227-705

SRV2227-706

SRV2227-703

SRV2227-704

SRV2227-701

LOG SUPPORT

PILOT

BRACKET

LEFT GRATE

LOG PIN

RIGHT GRATE

 

TINE

 

TINE

Figure 1. Reference Points for Log Placement

Figure 2. Refractory and Logs Installed

Figure 3. Install Back Refractory

CAUTION: Logs are fragile, handle with care. Install back refractory by placing it against the back of the firebox. See Figure

3.The back refractory must be held in the upright position until the side refractory is installed. Install the left side refractory as shown in Figure 4. Bend the refractory tab down as shown in Figure 5. Repeat this step for the right refractory panel.

 

 

 

 

Figure 4. Install Side Refractory

 

 

Figure 5. Bend Refractory Tab

30

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

Image 30
Contents Models What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceModule Reset Control Module OperationBefore Lighting Fireplace What to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening QFI35 QFI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance IPI ModelsFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionON/OFF Switch Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationOptional Accessories Requirements BLKFan Wiring with Remote AUX 300 Module FAN WHT GRN BLK BlowersFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Log Set Assembly LOGS-QFI30 Models QFI30 Install the Log AssemblyFor LOG #6 Mates With Slot Mate Notch With Grate BARSlot Log Set Assembly LOGS-QFI35 Models QFI35 Install Back RefractorySlot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 Air Shutter Setting Air Shutter SettingsQFI30 QFI35 Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Appliance Dimension Diagram Model DimensionsReference Materials Vent Kits Components Direct Vent Flex Liner KitsContact Information