G. Install the Log Assembly

Log Set Assembly: LOGS-QFI35

Models: QFI35

CAUTION: Logs are fragile, handle with care.

SRV2225-703SRV2225-701

SRV2225-704SRV2225-702

SRV2225-706 SRV2225-710

SRV2225-705

 

 

 

Figure 1. Refractory and Logs Installed

 

Figure 2. Install Back Refractory

Install back refractory by placing it against the back of the fi rebox. The back refractory must be held in the upright position until the side refractory is installed. Install the left side refractory as shown in Figure 3. Bend the refractory tab down as shown in Figure 4. Repeat this step for the right refractory panel.

REFRACTORY

TAB

Figure 3. Install Side Refractory

 

Figure 4. Bend Refractory Tab

33

Quadra-Fire • QFI30, QFI35

2227-900 Rev. H • 1/11

Image 33
Contents Models What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceModule Reset Control Module OperationBefore Lighting Fireplace Final inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size QFI35 QFI30Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsIPI Models Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsON/OFF Switch Electrical InformationBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 Air Shutter Setting Air Shutter SettingsQFI30 QFI35 Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System To remove any contaminants that may have accumulated on flame Appliance Dimension Diagram Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information