Quadra-Fire QF130 owner manual LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6

Page 35

LOG SLOT

5

MATELOG

PINS WITH

LOG SLOTS

FLAT SPOT

FOR LOG #6

Figure 11. Log #4

Figure 12. Place Log #5

Log #5 (SRV2225-710): Position Log #5 as shown in Figure 12. Mate the middle and left log pins with the two slots located on the bottom of the log. See Figure 13 for locations of log slots. The smaller end should be pointed toward the right side of the fi rebox.

LOG SLOTS

6

LOG RESTS

ON FLAT SPOTS

Figure 13. Log #5

Figure 14. Place Log #6

Log #6 (SRV2225-706): Rest the wide end of the log on the fl at spot of Log #5 as shown in Figure 12 and Figure 14. Place the narrow end on the fl at spot of Log #2. Flat spot on Log #2 is indicated in Figure 7.

LOG RESTS

ON FLAT SPOT

7

LOG GROOVE

MATES WITH

GRATE BAR

Figure 15. Place Log #7

Log #7 SRV2225-704): Note the location of the groove on the underside of the log. Place the opposite end on the fl at spot on Log #3. See Figure 9. Mate the groove on the underside of the log with the grate bar as shown in Figure 15, centered between the andirons.

 

2225-935B

Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

35

Image 35
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetControl Module Operation GAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed QFI35 QFI30 Fireplace Size RequirementsMinimum Fireplace Opening Minimum Fireplace SizeSide View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsIPI Models Placing, Securing and Leveling the Appli- anceDamper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire Plus Ignition System Wiring ON/OFF SwitchBLK Optional Accessories RequirementsAUX 300 Module FAN WHT GRN BLK Blowers Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-QFI30 Models QFI30Mates With Slot Mate Notch With Grate BAR For LOG #6Slot Install Back Refractory Log Set Assembly LOGS-QFI35 Models QFI35Slot on Log #2 LOG Slot Mate LOG Pins with LOG Slots Flat Spot For LOG #6 QFI30 QFI35 Air Shutter SettingAir Shutter Settings IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action To remove any contaminants that may have accumulated on flame Reference Materials Appliance Dimension DiagramModel Dimensions Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information