Majestic Appliances DVB4136 manual Fuel Conversion Kits

Page 47

 

 

 

DVB4136 Direct Vent Gas Fireplace

DVB4136 (continued)

 

 

Ref.

Description

DVB4136

 

36b.

Orifice - Front Burner (#57 / .043”) - Nat.

20002409

 

36c.

Orifice - Rear Burner (#54 / .0585”) - LP

20002150 (DVB4136IP/RP)

 

36c.

Orifice - Rear Burner (#53 / .0595”) - LP

54833 (DVB4136IP)

 

36d.

Orifice - Rear Burner (#41 / .096”) - Nat.

20004801 (DVB4136RFN)

 

36e.

Orifice - Rear Burner (39 / .0995) - Nat.

20013150 (DVB4136IN/RN)

 

37a.

Regulator Head - Nat.

10001006

 

37b.

Regulator Head - LP

10001007

38.

Transmitter

20002047

39.

Cord Set (RF Units)

20002541

40.

Antennae HW 395783-1 RFN/RFP Valve

20003561

41.

Electrical Cord (6ft.)

51865

42.

Fan w/Bracket (FK24)

54103

43.

Fan Temp. Sensor

51704

44.

Speed Control

51738

45.

Speed Control Knob

51882

46.

Switch ON/OFF

51842

47.

Flue Cover

20011858

48.

Flue Cover Plate

10002298

49.

Flue Cover Gasket

20011829

50.

Flue Cover Gasket

10002233

51.

Flue Plate Gasket

20011830

52.

Flue Pipe Assembly

20011826

53.

Gasket Plate Cover Flue Pipe

10002237

54.

Plate Relief w/Gasket Assy.

10002429

55.

Outer Collar Assembly

20011865

56.

Plate Relief w/Gasket Assembly Burner Tray

10004192

57.

Firestop

52523

58.

Zero Clearance Sleeve

54623

59.

Sensing Electrode w/Cable EN/EP (not shown)

57885

60.

Tubing 3/8” OD Aluminum (not shown)

20010564

61.

Nut 3/8” ID Brass, Compression (not shown)

7523136

62.

Remote Switch Kit (not shown)

53875

63.

Piezo Ignitor Replacement Kit (not shown)

20000062

64.

Ceramic Refractory Lining Kit (Optional) (not shown)

Refer to Page 48

65.

Air Shutter - Nat. (not shown)

20000129

66.

Air Shutter - LP (not shown)

20000680

Fuel Conversion Kits

Natural Gas to LP

 

DVB4136RP/RFP/IP

Kit #20013166

LP to Natural Gas

 

DVB4136RN/RFN/IN

Kit #20013165

20012322

47

Image 47
Contents Direct Vent Gas Fireplace Table of Contents Please Read the Following Carefully Installation & Operating InstructionsGas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsRef. DVB4136 Fireplace Dimensions Installed as Top VentRef. DV4136 Fireplace Dimensions Installed as Rear VentFraming Dimensions Q 40³⁄₈ 1026 mm R 40¹⁄₄ 1022 mm Hearth Locating Your FireplaceClearance to Combustibles MantelsGas Inlet and Manifold Pressures Gas Line InstallationFinal Finishing Gas SpecificationsEB-1 Electrical Box Remote ON/OFF Switch InstallationAlternate Switch Location EB-1 receptacle Complete conversion Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesRear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installation Twist Lock PipeVertical Sidewall Application Rear Wall Vent Installations Flex Vent Pipe+ B = 17 Max Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeHorizontal length requirement Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationMaximum elbow usage Vertical Through-the-Roof InstallationMin 610 mm Venting Components Operating Instructions Logs ID # Replacement Ceramic Hearth Panels if providedInstallation of Logs Log Identification ChartLeft Log Top Center Log Top Front Log Top Right Log Inspecting the Venting System Flame & Temperature AdjustmentFlame Characteristics To Turn Off Gas To Heater Lighting and Operating InstructionsFor Fireplaces Equipped with the SIT 820 Valve Valve in the on position Lighting InstructionsTurning Off the Gas to the Appliance For Fireplaces equipped with AF4000 Gas Valve Lighting & Operating InstructionsSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemAF4000 Valve TroubleshootingIgniter operation Troubleshooting AF4000 ValveAF4000 MOD Module End Instructions for RF Comfort Control Valve Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeChange Between F/C Temperature Units Delay Timer ModeAuto Mode Fan Override During Auto ModeAuto Path LED Count Service ActionLocal Path On Path SkyTech Valve Conversions must be completed by qualified personnelFuel Conversion Instructions Burner Orifice ConversionPilot Orifice Conversion Installation PrecautionsConversion Procedure Model Fuel Type Front Rear Injector Orifice Size MatrixFront Rear Minimum Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Logs May Be HOTDescription DVB4136 DVB4136 Description Fuel Conversion Kits Hard Direct Wire Hook Up Optional AccessoriesFK12 Fan Assembly FK24 Fan AssemblyDecorative Bay Windows Remote ControlsInstallation Instructions Ceramic Refractory PanelsArch/Square Face Kit Battery BackupInstallation Procedure Limited Lifetime Warranty Efficiency Ratings