Majestic Appliances DVB4136 manual Fireplace Dimensions Installed as Rear Vent, Ref. DV4136

Page 6

DVB4136 Direct Vent Gas Fireplace

Fireplace Dimensions (Installed as Rear Vent)

U

J

U V

Rough

I

Opening

 

Depth

 

S

 

 

H

 

J Recessed

 

Nailing Flange

 

R - Rough Opening Width

 

Rough

 

 

 

 

T

Opening

 

 

 

 

 

Height

 

 

 

 

 

 

 

F

 

 

W

Q

 

 

Electrical

P

 

 

Access

B

C

 

D

 

 

Gas Line

O

 

 

 

 

 

 

 

 

Access

 

 

 

 

E

M K N

 

 

A

G

 

L

Fig. 2 Fireplace specifications and framing dimensions.

Ref. DV4136

A40” (1016 mm)

B 36¹⁄” (918 mm) C 36¹⁄” (918 mm) D 24¹⁄” (613 mm)

E6” (152 mm)

F6” (152 mm)

G1” (25 mm) H 20⁵⁄” (524 mm)

I 22⁵⁄” (575 mm)

J 5/8” (16 mm)

K 15” (381 mm)

L 3⁵⁄” (92 mm)

M 7¹⁄” (191 mm)

N 2¹⁄” (54 mm) O 30³⁄” (781 mm)

P 31⁵⁄” (803 mm)

Framing Dimensions Q 40³⁄” (1026 mm) R 40¹⁄” (1022 mm)

S 20⁵⁄” (524 mm)

T 64³⁄” (1645 mm) U 45³⁄” (1162 mm)

V 32³⁄” (822 mm)

W 40” (1016 mm)

6

20012322

Image 6
Contents Direct Vent Gas Fireplace Table of Contents Installation & Operating Instructions Please Read the Following CarefullyRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Installed as Top Vent Ref. DVB4136Fireplace Dimensions Installed as Rear Vent Framing Dimensions Q 40³⁄₈ 1026 mm R 40¹⁄₄ 1022 mmRef. DV4136 Mantels Locating Your FireplaceClearance to Combustibles HearthGas Specifications Gas Line InstallationFinal Finishing Gas Inlet and Manifold PressuresRemote ON/OFF Switch Installation Alternate Switch LocationEB-1 Electrical Box EB-1 receptacle Optional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesRear Wall Vent Application Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall Application+ B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Operating Instructions Log Identification Chart Replacement Ceramic Hearth Panels if providedInstallation of Logs Logs ID #Left Log Top Center Log Top Front Log Top Right Log Flame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Lighting and Operating Instructions For Fireplaces Equipped with the SIT 820 ValveTo Turn Off Gas To Heater Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas ValveTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting AF4000 ValveTroubleshooting AF4000 Valve Igniter operationAF4000 MOD Module End On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On Path Burner Orifice Conversion Conversions must be completed by qualified personnelFuel Conversion Instructions SkyTech ValveInstallation Precautions Conversion ProcedurePilot Orifice Conversion Injector Orifice Size Matrix Front Rear MinimumModel Fuel Type Front Rear Logs May Be HOT MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDescription DVB4136 DVB4136 Description Fuel Conversion Kits FK24 Fan Assembly Optional AccessoriesFK12 Fan Assembly Hard Direct Wire Hook UpCeramic Refractory Panels Remote ControlsInstallation Instructions Decorative Bay WindowsBattery Backup Installation ProcedureArch/Square Face Kit Limited Lifetime Warranty Efficiency Ratings