Majestic Appliances DVB4136 manual Venting Components

Page 24

DVB4136 Direct Vent Gas Fireplace

Venting Components

7TDVRVT - Through the wall Rear Vent Termination

Starter Kit -

Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) Models 7TDVTK/TV - Hot Touch Termination Kits Model 7TDVTVTK/TV - Cool Touch Termination Kit

Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof

Starter Kit for Below Grade Installation

Model 7TDVSKS -Snorkel Kit (Twist Lock Pipe) Model 7FDVSKS -Snorkel Kit (Flex Vent Pipe)

Starter Pipe

Model 7TDVP 20/8 - 24” Starter Pipe Bulk

Model 7FDVP 30/8 - 30” Flex Pipe Bulk

45o Elbow

7TDV45 for Rear Vent to Vertical Vent or Vertical/Horizontal Offsets

90o Transition Elbow

7TDVRT90 for Rear Vent to Vertical Vent

90° Elbow

7TDV90 Vertical/Horizontal Offset

Telescopic vent sections

7TDVP1117 -11” to 17” adjustable length 7TDVP3567 -35” to 67” adjustable length

Pipe sections for vertical or horizontal venting

 

 

Model 7TDVP8”

-

4 per box

 

 

 

 

Model 7TDVP12”

-

4 per box

 

 

Model 7TDVP24”

-

4 per box

 

 

Model 7TDVP36”

 

 

 

 

Model 7TDVP48”

 

 

 

 

 

 

 

 

 

Firestop Spacer

 

 

 

 

Model 7DVFS

 

 

 

 

 

 

 

 

 

Attic Insulation Shield

 

 

 

 

Model 7DVAIS

 

 

Vertical/Horizontal Combination Offset Support

Model 7DVCS

24

20012322

Image 24
Contents Direct Vent Gas Fireplace Table of Contents Installation & Operating Instructions Please Read the Following CarefullyRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Installed as Top Vent Ref. DVB4136Fireplace Dimensions Installed as Rear Vent Framing Dimensions Q 40³⁄₈ 1026 mm R 40¹⁄₄ 1022 mmRef. DV4136 Locating Your Fireplace Clearance to CombustiblesMantels HearthGas Line Installation Final FinishingGas Specifications Gas Inlet and Manifold PressuresRemote ON/OFF Switch Installation Alternate Switch LocationEB-1 Electrical Box EB-1 receptacle Optional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesRear Wall Vent Application Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall Application+ B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Operating Instructions Replacement Ceramic Hearth Panels if provided Installation of LogsLog Identification Chart Logs ID #Left Log Top Center Log Top Front Log Top Right Log Flame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Lighting and Operating Instructions For Fireplaces Equipped with the SIT 820 ValveTo Turn Off Gas To Heater Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas ValveTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting AF4000 ValveTroubleshooting AF4000 Valve Igniter operationAF4000 MOD Module End Shut Off Procedure Transmitter Operation Off ModeOn Manual Mode Instructions for RF Comfort Control ValveDelay Timer Mode Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On Path Conversions must be completed by qualified personnel Fuel Conversion InstructionsBurner Orifice Conversion SkyTech ValveInstallation Precautions Conversion ProcedurePilot Orifice Conversion Injector Orifice Size Matrix Front Rear MinimumModel Fuel Type Front Rear Maintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentDescription DVB4136 DVB4136 Description Fuel Conversion Kits Optional Accessories FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpRemote Controls Installation InstructionsCeramic Refractory Panels Decorative Bay WindowsBattery Backup Installation ProcedureArch/Square Face Kit Limited Lifetime Warranty Efficiency Ratings