Majestic Appliances DVB4136 Remote Controls, Ceramic Refractory Panels, Installation Instructions

Page 49

Remote Controls

Optional remote control units are available to control different functions of the appliance.

Model

Functions Controlled

RC1

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

Ceramic Refractory Panels

Ceramic refractory panels are available to line the fire- box area.

Kit

Color

DV4136CRB

Classic Black

DV4136CRR

Colonial Red

DV4136CRG

Silver Gray

DV4136CRSS

Sandstone

DV4136CRCG

Country Gray

Take care when handling the refractory panels as they are fragile until held in place and supported.

Installation Instructions

1.Remove window frame assembly and logs.

2.Remove three (3) screws securing heat shield to combustion dome. (Fig. 80)

3.Place rear ceramic panel in back of unit. (Fig. 81)

4.Place side panels.

5.Replace heat shield, logs and window frame assem- bly.

Heat Shield

Section A

Heat Shield

 

(3)

 

Screws

 

Side View

 

Section A

 

H103

Fig. 80 Heat shield.

 

DVB4136 Direct Vent Gas Fireplace

 

Rear Ceramic Panel

 

Back of

 

Firebox

Burner

 

Rear Log

 

Support

 

H102

Fig. 81

Rear ceramic panel placement.

Decorative Bay Windows

The bay window kit is available for the DVB4136 only.

Installation

Remove the existing louvre assembly top.

Assemble the Bay Window Kit according to the instruc- tions supplied with the kit. (Fig. 82)

 

Upper Grille Assembly

Ceramic

 

Refractory

Ceramic

 

Refractory

Window

 

Assembly

 

Base Grille

 

Assembly

FP1194

Fig. 82 Bay window.

 

Decorative Frame Trims

A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit. Contact your authorized distributor for details of the trim kits and ordering information for the trim kits applicable to this model appliance.

20012322

49

Image 49
Contents Direct Vent Gas Fireplace Table of Contents Please Read the Following Carefully Installation & Operating InstructionsGas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsRef. DVB4136 Fireplace Dimensions Installed as Top VentFraming Dimensions Q 40³⁄₈ 1026 mm R 40¹⁄₄ 1022 mm Fireplace Dimensions Installed as Rear VentRef. DV4136 Clearance to Combustibles Locating Your FireplaceMantels HearthFinal Finishing Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Box EB-1 receptacle Complete conversion Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Application Zero clearance sleeve is only required for combustible walls Rear Wall Vent Installation Twist Lock PipeVertical Sidewall Application Rear Wall Vent Installations Flex Vent Pipe+ B = 17 Max Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeHorizontal length requirement Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationMaximum elbow usage Vertical Through-the-Roof InstallationMin 610 mm Venting Components Operating Instructions Installation of Logs Replacement Ceramic Hearth Panels if providedLog Identification Chart Logs ID #Left Log Top Center Log Top Front Log Top Right Log Flame Characteristics Flame & Temperature AdjustmentInspecting the Venting System For Fireplaces Equipped with the SIT 820 Valve Lighting and Operating InstructionsTo Turn Off Gas To Heater Turning Off the Gas to the Appliance Lighting InstructionsValve in the on position For Fireplaces equipped with AF4000 Gas Valve Lighting & Operating InstructionsSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemAF4000 Valve TroubleshootingIgniter operation Troubleshooting AF4000 ValveAF4000 MOD Module End Transmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Instructions for RF Comfort Control ValveAuto Mode Delay Timer ModeFan Override During Auto Mode Change Between F/C Temperature UnitsAuto Path LED Count Service ActionLocal Path On Path Fuel Conversion Instructions Conversions must be completed by qualified personnelBurner Orifice Conversion SkyTech ValveConversion Procedure Installation PrecautionsPilot Orifice Conversion Front Rear Minimum Injector Orifice Size MatrixModel Fuel Type Front Rear Cleaning the Standing Pilot Control System MaintenanceLogs May Be HOT Burner and Burner CompartmentDescription DVB4136 DVB4136 Description Fuel Conversion Kits FK12 Fan Assembly Optional AccessoriesFK24 Fan Assembly Hard Direct Wire Hook UpInstallation Instructions Remote ControlsCeramic Refractory Panels Decorative Bay WindowsInstallation Procedure Battery BackupArch/Square Face Kit Limited Lifetime Warranty Efficiency Ratings