Majestic Appliances DVB4136 manual Efficiency Ratings

Page 52

Efficiency Ratings

Model

EnerGuide Ratings

Steady State (%)

D.O.E.

 

Fireplace Efficiency (%)

Fan-OFF

Fan-ON

(AFUE%)

DVB4136RN

62.4

82

83

64

DVB4136RP

62.4

83

84

64

DVB4136IN

62.4

82

83

64

DVB4136IP

62.4

83

84

64

DVB4136RFN

62.4

82

83

64

DVB4136RFP

62.4

83

84

64

CFM Corporation

2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3

800-668-5323 • www.cfmcorp.com

Image 52
Contents Direct Vent Gas Fireplace Table of Contents Installation & Operating Instructions Please Read the Following CarefullyRequirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Installed as Top Vent Ref. DVB4136Framing Dimensions Q 40³⁄₈ 1026 mm R 40¹⁄₄ 1022 mm Fireplace Dimensions Installed as Rear VentRef. DV4136 Locating Your Fireplace Clearance to CombustiblesMantels HearthGas Line Installation Final FinishingGas Specifications Gas Inlet and Manifold PressuresAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Box EB-1 receptacle Optional Top Vent Application Complete conversionGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphRear Wall Vent Application Rear Wall Vent Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall Application+ B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Maximum elbow usageMin 610 mm Venting Components Operating Instructions Replacement Ceramic Hearth Panels if provided Installation of LogsLog Identification Chart Logs ID #Left Log Top Center Log Top Front Log Top Right Log Flame Characteristics Flame & Temperature AdjustmentInspecting the Venting System For Fireplaces Equipped with the SIT 820 Valve Lighting and Operating InstructionsTo Turn Off Gas To Heater Turning Off the Gas to the Appliance Lighting InstructionsValve in the on position Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas ValveTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting AF4000 ValveTroubleshooting AF4000 Valve Igniter operationAF4000 MOD Module End Shut Off Procedure Transmitter Operation Off ModeOn Manual Mode Instructions for RF Comfort Control ValveDelay Timer Mode Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On Path Conversions must be completed by qualified personnel Fuel Conversion InstructionsBurner Orifice Conversion SkyTech ValveConversion Procedure Installation PrecautionsPilot Orifice Conversion Front Rear Minimum Injector Orifice Size MatrixModel Fuel Type Front Rear Maintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentDescription DVB4136 DVB4136 Description Fuel Conversion Kits Optional Accessories FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpRemote Controls Installation InstructionsCeramic Refractory Panels Decorative Bay WindowsInstallation Procedure Battery BackupArch/Square Face Kit Limited Lifetime Warranty Efficiency Ratings