general
Installation information
J= 2-way, modulating, 0.7 Cv (50 psig)*
K=
N=
P=
Q=
R=
X=
Y=
Z=
Digit 28 — auxiliary control valve 0 = none
A=
B=
C=
D=
E=
F=
G=
H=
J=
K=
L=
N=
P=
Q=
R=
X=
Y=
Z=
Digit 29 — piping packages 0 = none
A = basic ball valve S & R
B = basic ball valve S/man. crkt set
C = basic ball valve S & R w/auto crkt set D = deluxe ball valve S & R
E = deluxe ball valve S /man. crkt set R
F = deluxe ball valve S & R w/auto crkt set
Digit 30 — control type 0 = none
A = fan speed switch
E = Tracer ZN010
F = Tracer ZN510
G = Tracer ZN520
H = CSTI
Digit 31 — control option
D = unit mtd fan mode, unit voltage, K = wall mtd fan mode
V = unit mtd fan sp w/ setpnt
X = unit mtd fan sp w/ wall mtd setpnt Y = unit mtd fan sp & wall mtd setpnt w/
comm.
Z = unit mtd fan sp, on/cancel, setpnt w/ comm.
1 = wall mtd on/cancel w/ comm.
2 = wall mtd fan speed, setpnt, on/cancel w/ comm.
3 = unit mtd fan speed switch, low voltage 4 = wall mtd digital zone sensor, fan sp w/
setpnt, on/cancel, comm.
5 = wall mtd digital zone sensor, setpnt, on/cancel, comm.
Digit 32 — IAQ options 0 = none
1 = dehumidification
4 = dehumidification w/sensor
Digit 33 — cntrl function #1
0 = w/o exhaust fan/damper or alarm
Digit 34 — cntrl function #2
0 = w/o occupant call or IAQ status
Digit 35 — control function #3 0 = none
1 = occ/unocc control
2 = condensate overflow detection
3 = occ/unocc & condensate overflow
Digit 36 — cntrl function #4 0 = none
1 = smoke input
2 = low temperature detection
3 = smoke input & low limit sensor
Digits 37, 38 — future cntrl functions
Digit 39 — projection panel/falseback
0 = none
A = 5/8”standard vertical recessed panel B = 2” projection panel
C = 2.5” projection panel D = 3” projection panel E = 3.5” projection panel F = 4” projection panel G = 4.5” projection panel H = 5” projection panel J = 5.5”projection panel K = 6” projection panel L = 2”falseback
M = 3” falseback N = 4” falseback P = 5” falseback Q = 6” falseback R = 7” falseback T = 8” falseback
Digit 40 — main autoflow gpm
A = 0.5 | G = 3.0 | N = 7.0 |
B = 0.75 | H = 3.5 | P = 8.0 |
C = 1.0 | J = 4.0 | Q = 9.0 |
D = 1.5 | K = 4.5 | R = 10.0 |
E = 2.0 | L = 5.0 | T = 11.0 |
F = 2.5 | M= 6.0 | U = 12.0 |
Digit 41 — auxiliary autoflow gpm | ||
A = 0.5 | F = 2.5 | L = 5.0 |
B = 0.75 | G = 3.0 | M= 6.0 |
C = 1.0 | H = 3.5 | N = 7.0 |
D = 1.5 | J = 4.0 | P = 8.0 |
E = 2.0 | K = 4.5 |
|
Digit 42 — subbase |
| |
0 = none |
|
|
A = 2” subbase | D =5” subbase | |
B = 3” subbase | E =6” subbase | |
C = 4” subbase | F =7” subbase |
Digit 43 — recessed flange 0 = none
A = recessed flange
Digit 44 — wall boxes 0 = none
A = anodized wall box
6 |