Trane UniTrane Fan-Coil & Force Flo Air Conditioners manual Table I-GI-1. Fan-coil component data

Page 7

general

Installation information

Table I-GI-1. Fan-coil component data

unit size

02

03

04

06

08

10

12

Coil Data

 

 

 

 

 

 

 

Face Area — Ft2 (cm2)

0.8 (743)

0.8 (743)

1.1 (1020)

1.6 (1490)

2.1 (1950)

3.2 (2970)

3.2 (2970)

LxDxH — In. (cm)

 

 

 

 

 

 

 

2-Row

15x1.7x8

15x1.7x8

20x1.7x8

29.5x1.7x8

38x1.7x8

57x1.7x8

57x1.7x8

 

(38x4x20)

(38x4x20)

(51x4x20)

(75x4x20)

(97x4x20)

(145x4x20)

(145x4x20)

3-Row

15x2.6x8

15x2.6x8

20x2.6x8

29.5x2.6x8

38x2.6x8

57x2.6x8

57x2.6x8

 

(38x7x20)

(38x7x20)

(51x7x20)

(75x7x20)

(97x7x20)

(145x7x20)

(145x7x20)

4-Row

15x3.5x8

15x3.5x8

20x3.5x8

29.5x3.5x8

38x3.5x8

57x3.5x8

57x3.5x8

 

(38x9x20)

(38x9x20)

(51x9x20)

(75x9x20)

(97x9x20)

(145x9x20)

(145x9x20)

Volume — Gal. (Liters)

 

 

 

 

 

 

 

1-Row(Heat)

.06 (.23)

.06 (.23)

.08 (.30)

.11 (.42)

.14 (.53)

.21 (.79)

.21 (.79)

2-Row

.12 (.45)

.12 (.45)

.15 (.57)

.22 (.83)

.28 (1.06)

.42 (1.59)

.42 (1.59)

3-Row

.18 (.68)

.18 (.68)

.23 (.87)

.33 (1.25)

.42 (1.59)

.62 (2.35)

.62 (2.35)

4-Row

.24 (.91)

.24 (.91)

.30 (1.14)

.44 (1.67)

.56 (2.12)

.83 (3.14)

.83 (3.14)

Fins/Ft (cm)

 

 

 

 

 

 

 

2-Row

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

3-Row

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

4-Row

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

144 (4.7)

Reheat Coil Data (1-Row)

 

 

 

 

 

 

 

Hot Water or Steam

 

 

 

 

 

 

 

Face Area — Ft2 (cm2)

0.6

0.6

0.8

1.2

1.6

2.4

2.4

 

(557)

(557)

(743)

(1120)

(1490)

(2230)

(2230)

LxDxH — In. (cm)

15x1.5x6

15x1.5x6

20x1.5x6

29.5x1.5x6

38x1.5x6

57x1.5x6

57x1.5x6

 

(38x4x15)

(38x4x15)

(51x4x15)

(75x4x15)

(97x4x15)

(145x4x15)

(145x4x15)

Volume — Gal. (Liters)

.12 (.45)

.12 (.45)

.15 (.57)

.22 (.83)

.28 (1.06)

.42 (1.59)

.42 (1.59)

Fins/Ft (cm)

48 (1.6)

48 (1.6)

48 (1.6)

48 (1.6)

48 (1.6)

48 (1.6)

48 (1.6)

Fan/MotorData

 

 

 

 

 

 

 

Fan Quantity

1

1

1

2

2

3

3

Size — Dia” x Width” (cm)

6.31x4

6.31x6.5

6.31x7.5

6.31x6.5

6.31x7.5

(1) 6.31x7.5

6.31x7.5

 

(16x10)

(16x17)

(16x19)

(16x17)

(16x19)

(16x19)

(16x19)

Size — Dia” x Width” (cm)

 

 

 

 

 

(2) 6.31x6.5

 

 

 

 

 

 

 

(16x6.5)

 

MotorQuantity

1

1

1

1

1

2

2

Filter Data

 

 

 

 

 

 

 

1” (cm) TA and Pl. Media

 

 

 

 

 

 

 

Quantity

1

1

1

1

1

1

1

Size — In. (cm)

87/8 x 191/8

87/8 x 191/8

87/8 x 241/8

87/8 x 335/8

87/8 x 421/8

87/8 x 611/8

87/8 x 611/8

 

(23x49)

(23x49)

(23x61)

(23x85)

(23x107)

(23x155)

(23x155)

1” Fresh Air Filter (only on cabinet styles D, E, and H with bottom return and fresh air opening)

 

 

 

Quantity

1

1

1

1

1

1

1

Size — In. (cm)

51/2 x 191/8

51/2 x 191/8

51/2 x 241/8

51/2 x 335/8

51/2 x 421/8

51/2 x 611/8

51/2 x 611/8

(14 x 49)

(14 x 49)

(14 x 61)

(14 x 85)

(14 x 107)

(14 x 156)

(14 x 156)

 

Table I-GI-2. Low vertical fan-coil component data

unit size

03

04

06

Coil Data

 

 

 

Face Area — Ft2 (cm2)

1.1 (1020)

1.6 (1490)

2.1 (1950)

LxDxH — In. (cm)

 

 

 

2-Row

20x1.7x8 (51x4x20)

29.5x1.7x8 (75x4x20)

38x1.7x8 (97x4x20)

3-Row

20x2.6x8 (51x7x20)

29.5x2.6x8 (75x7x20)

38x2.6x8 (97x7x20)

Volume — Gal. (Liters)

 

 

 

1-Row(Heat)

.08 (.30)

.11 (.42)

.14 (.53)

2-Row

.15 (.57)

.22 (.83)

.28 (1.06)

3-Row

.23 (.87)

.33 (1.25)

.42 (1.59)

Fins/Ft

 

 

 

2-Row

144 (4.7)

144 (4.7)

144 (4.7)

3-Row

144 (4.7)

144 (4.7)

144 (4.7)

Fan/MotorData

 

 

 

Fan Quantity

1

1

1

Size — Dia”x Width” (cm)

5x23 (13x59)

5x32 (13x83)

5x41 (13x105)

MotorQuantity

1

1

1

Filter Data

 

 

 

1” (2.5 cm) TA

 

 

 

Quantity

1

1

1

Size — In. (cm)

87/8x241/8 (23x61)

87/8x335/8 (23x85)

87/8 x 421/8 (23x107)

UNT-SVX07A-EN

7

Image 7
Contents Models FC & FF ZO and later design sequence Installation, Operation, and MaintenanceCommon Hvac Acronyms General informationContents Model Number GeneralModel Number Description GeneralDigit 31 control option Digit 28 auxiliary control valve 0 = noneDigit 29 piping packages 0 = none Digit 30 control type 0 = noneTable I-GI-2. Low vertical fan-coil component data Table I-GI-1. Fan-coil component dataModel M inverted vertical cabinet Available ModelsModel E horizontal recessed Model K low vertical cabinetFactory-Installed Piping Packages Vertical Concealed, Model a DimensionsInstallation Weights Vertical Concealed Unit Dimensions & weights, in-lbsVertical Cabinet, Model B Vertical Cabinet Unit Dimensions, in-lbsHorizontal Concealed, Model C Horizontal Concealed Unit Dimensions, in-lbsHorizontal Cabinet, Model D Horizontal Cabinet Unit Dimensions, in-lbsHorizontal Recessed Unit Dimensions, in-lbs Installation Dimensions WeightsHorizontal Recessed, Model E Vertical Wall Hung Cabinet, Model F Vertical wall hung cabinet unit dimensions & weights, in-lbsVertical Recessed, Model H Vertical Recessed Unit Dimensions, in-lbsVertical Slope Top, Model J Vertical Slope Top Unit Dimensions, in-lbsLow Vertical Concealed, Model K Low Vertical Concealed Unit Dimensions, in-lbsLow Vertical Cabinet, Model L Low Vertical Cabinet Unit Dimensions, in-lbsInverted Vertical Cabinet, Model M Inverted vertical cabinet unit dimensions & weights, in-lbsInverted Vertical Recessed, Model N Inverted vertical recessed unit dimensions & weights, in-lbsFan-Coil Coil Connections Vertical Units Horizontal Units Horizontal Units Inverted Units Force Flo Coil Connections Vertical UnitsFresh Air Opening Dimensions, Horizontal Units Fresh Air Opening Dimensions, Vertical Units Wall Box Wall Box DimensionsProjection Panel Projection Panel DimensionsJobsite Storage Pre-installation Installation considerationsInstallation Preparation Receiving and HandlingPre-Installation Checklist Service AccessPiping Considerations Connecting field piping to coilMechanical Duct ConnectionsCondensate Drain Figure I-MR-4. Close-up view of the changeover sensor Venting the Hydronic CoilFigure I-MR-8. Manual circuit setter valve Balancing The Manual Circuit Setter ValveMechanical Steam Piping Code of System Components in Piping DiagramElectrical Unit Wiring DiagramsSupply Power Wiring Wall Mounted Control Interconnection WiringTable I-ER-3. Decimal to fractional HP kW conversion Table I-ER-2. Low vertical free discharge motors, 115 voltTable I-ER-9. Electric heat kW Table I-ER-8. Fan-coil electric heat kWTable I-ER-11. Force Flo single stage, low kW electric heat Table I-ER-10. Force Flo single-stage, max kW electric heatTable I-ER-12. Force Flo 2-stage electric heat Installing the Unit InstallationUnit Leveling Figure I-IP-5. Zone sensor only Figure I-IP-3. Zone sensor with on/cancel Comm jackZone Sensor Installation Installing Wall Mounted ControlsWiring Instructions Fan Mode Switch InstallationUnit Leveling Installation ChecklistDevice Addressing Communication WiringRecommended Communication Wiring Practices Pre-startupPre-Startup Checklist Tracer ZN510 & ZN520 Unit Startup Installation startupRelay Board Manual Fan Mode SwitchGeneral Operation information General InformationTracer ZN520 Operation Fan Mode Switch OperationSequence Tracer ZN010 & ZN510 OperationBinary Outputs Binary InputsSupply Fan Operation Fan Mode SwitchAnalog Inputs Zone SensorsTracer ZN520 Sequence of Operation Heating Operation Cooling OperationDischarge Air Tempering Continuous Fan Operation Fan Mode OperationEconomizer Damper Option Fan Start on High SpeedElectric Heat Operation Manual Fresh Air DamperBinary Outputs Table O-SO-12. Binary input configurationsTable O-SO-13. Binary output configuration Data SharingTable O-SO-15. Analog inputs Table O-SO-14. Analog inputsZone Sensor Fan SwitchOn/Cancel Buttons Table O-SO-16. Zone sensor wiring connectionsTable M-D-1. Tracer ZN520 Diagnostics Maintenance diagnosticsCycling the Fan Switch Translating Multiple DiagnosticsResetting Diagnostics Diagnostic ResetTable M-D-4. Valves Stay Closed Table M-D-3. Fan outputs do not energizeTable M-D-5. Valves Stay Open Table M-D-7. Fresh Air Damper Stays Open Table M-D-6. Electric Heat Not OperatingTable M-D-8. Fresh Air Damper Stays Closed Switch SW2 Electric Heat Maintenance troubleshootingTroubleshooting the Relay Board Switch SW1 Controller TypeYellow Comm LED Troubleshooting Tracer ZN010, ZN510 & ZN520Red Service LED Green Status LEDBOP5 BOP6 Table M-T-1. Test sequence for 1-heat/1-cool configurationsMaintenance Procedures MaintenanceMain Drain Pan Steam and Hydronic Coil Cleaning Procedure Coil MaintenanceWinterizing the Coil Replacing the Motor Control Device ReplacementAnnual Maintenance Periodic Maintenance ChecklistsMonthly Checklist Monthly MaintenanceCsti Fan Speed Switch Typical wiringCsti Non Fan Speed Switch Line voltage fan speed switch Tracer ZN010 with electric heat Tracer ZN510 with main and auxilliary valves ZN520 with 2-stage electric heat Page Page Page PL-TD-UNT-SVX07A-EN