Honeywell VISTA-40, 2-Partitioned Security System manual Programming With #93 Menu Mode

Page 10

Programming With #93 Menu Mode

NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers should be programmed via Device programming.

After programming all system related programming fields in the usual way, press #93 while still in programming mode to display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence.

UL

For UL installations, verify that the audio alarm verification feature is disabled.

 

#93 MENU MODE KEY COMMANDS

The following is a list of commands used while in the menu mode.

#93

Enters Menu mode

[4]

Serves as ENTER key. Press to have keypad accept entry.

[#]Backs up to previous screen.

0 Press to answer NO

1 Press to answer YES

01-09 All data entries are either 1-digit or 2-digit entries.

00 Exits menu mode, back into field programming mode, when entered at the first question for each category.

Menu selections are as follows:

PROMPTEXPLANATION

ZONE PROG?

 

1 = YES 0 = NO

0

For programming the following:

Zone Number

Zone Response Type

Partition Number for Zone

Dialer report code for zone

Input Device Type for zone (whether RF, polling loop, etc.)

Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.

 

EXPERT MODE?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

ALPHA PROG?

 

 

1 = YES

0 = NO

0

 

Same as Zone Programming except:

Done with a minimum number of keystrokes.

Can program wireless keys using pre-defined templates.

For entering alpha descriptors for the following:

Zone Descriptors

Installer's Message

Custom Words

Partition Descriptors

Relay Descriptors

DEVICE PROG?

 

1 = YES 0 = NO

0

For defining the following device characteristics for addressable devices, including keypads, RF receivers (5881), output relay modules (4204), and 4285/4286 VIP Module:

Device Address

Device Type

Keypad Options (incl. partition assignment)

RF House ID

 

RELAY PROG?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

RLY VOICE DESCR?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

CUSTOM INDEX ?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

For defining relay functions.

For entering voice descriptors for relays to be used with the 4285/4286 VIP Module.

For creating custom word substitutes for VIP Module annunciation.

– 10 –

Image 10
Contents $0&29,67$ N7001PRV5 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form 54 *57 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 1st Page Fields Partition-Specific FieldsPartition # Program Fields 2nd Page FieldsProgramming With #93 Menu Mode Enter Zone no = Quit Zone ProgrammingSET to CONFIRM? = YES Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipEnter Zone no Expert Mode Zone ProgrammingProgram field 200 Number of Partitions SET to CONFIRM?Input S/N XXX-XXXX From TemplateTemplate Loop Function Wireless Key Default Templates 58045804BD Zone Type Template Loop FunctionAlpha Descriptors Programming Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Zone Descriptors Select Zone Descriptor mode Exit Edit MODE?Accept the word Select Default Screen modeSelect Custom Word Mode Select the next wordEnter the custom word number 01-20 you want to create Type the word using one of two methods as followsFollow the same procedure as for custom words Save the word by pressingCharacter Ascii Chart Alpha Descriptor VocabularyRF Expander Device ProgrammingAlpha Keypad VIP ModuleRelay Programming AlarmFault TroubleEnter Relay # Relay Output Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Relay Action No Response Start Event Not UsedRelay Type Plex ECP Address Module RELAY# House Code Zone List ProgrammingStart Partn ANY Partition Unit CodeRelay Voice Descriptors Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets Descriptor Prim Partition # Char max Sub. #Access Codes & User Definitions for Partitions 1 DefaultsZone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Types Zone Definitions for Keypad Panic Zones 95, 96Zone Definitions for System Zones 70, 88 89, 90, 91 Input TypesRelay Outputs Worksheets Choices for System Operation arePage Ademco VISTA-40 Summary of Connections GroundEileen Way, Syosset, New York