Before programming any security system, you should first define the installation. To help you lay out a partitioned system, use the following worksheets. This will further simplify the programming process.

 

Descriptor

Prim.

Partition #

(4-char max)

Sub. #

Partition 1

Partition 2

Keyswitch Arming Partition Assignment (1-2):

Wireless Keypad Partition Assignment (1-2):

Voice Module Partition Assignment (1-2):

Use Partition Descriptor (yes/no)?

PARTITIONS

Sec.

Alpha Default Message

Sub. #

(32-character maximum)

 

 

 

 

 

 

 

 

 

 

 

 

COMMUNICATION OPTIONS BY PARTITION

Option

Part. 1

Part. 2

Swinger Suppression Count 00-15; 00=no suppression

Cancel Report After Disarm

Dialer Reports for Panic (* + 1)

Dialer Reports for Panic (# + 3)

Dialer Reports for Panic (* + #)

Dialer Reports for Duress

Burglary Alarm Communications Delay (16 sec.)

SYSTEM DEFINITIONS BY PARTITION (enter values or yes/no)

Option

Part. 1

Entry Delay #1 (00, 30-225 seconds):

Exit Delay #1 (00, 45-225 seconds):

Entry Delay #2 (00, 30-225 seconds):

Exit Delay #2 (00, 45-225 seconds):

Quick Arming

Multiple Alarms per Arming

Console Panic for Zone 95 (* + 1)

Console Panic for Zone 96 (# + 3)

Console Panic for Zone 99 (* + #)

Allow Sign-on (GOTO function)

Non-Bypassable Zone*

Sounder Timeout Duration for Bell (2 min. increments)

Console Annunciation During Entry**

Console Annunciation During Exit

Confirmation of Arming Ding for Bell

Chime on Bell

Access Control Relay (field 1*76)

*Can be any zone 01-64.

**no = 3 beeps; yes = continuous

PRINTER OPTIONS

12- or 24-hour Time format

EVENT LOG TYPES

Option

No

Yes

Alarm

Trouble

Bypass

Open/Close

System

Part. 2

– 27 –

Image 27
Contents N7001PRV5 5/04 Rev a $0&29,67$Table of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-40 Programming Form 59 *62 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 54 *57 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 2nd Page Fields Partition-Specific FieldsPartition # Program Fields 1st Page FieldsProgramming With #93 Menu Mode Zone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? = YES Enter Zone no = QuitInput Type Input S/N AXXX-XXXXInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsSET to CONFIRM? Expert Mode Zone ProgrammingProgram field 200 Number of Partitions Enter Zone noFrom Template Input S/N XXX-XXXXZone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionExit Edit MODE? Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Zone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createAlpha Descriptor Vocabulary Character Ascii ChartVIP Module Device ProgrammingAlpha Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Output Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Unit Code Zone List ProgrammingStart Partn ANY Partition Relay Type Plex ECP Address Module RELAY# House CodeRelay Voice Descriptors Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationDescriptor Prim Partition # Char max Sub. # System Layout WorksheetsDefaults Access Codes & User Definitions for Partitions 1Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Input Types Zone Definitions for Keypad Panic Zones 95, 96Zone Definitions for System Zones 70, 88 89, 90, 91 Zone TypesChoices for System Operation are Relay Outputs WorksheetsPage Ground Ademco VISTA-40 Summary of ConnectionsEileen Way, Syosset, New York