Honeywell 2-Partitioned Security System, VISTA-40 Relay Output Devices Programming, Enter Relay #

Page 23

Relay Output Devices Programming

From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt. Press [0] (NO) to each menu option until the "RELAY PROG?" prompt appears. Press [1] (YES).

While in this mode, press [] to advance to next screen. Press [#] to back up to the previous screen.

PROMPTEXPLANATION

ENTER RELAY #

(00=QUIT) 01

02 A EV ZL P STT 0 0 00 0

02A ZL ZT P STOP 0 00 00 0

 

02

RELAY ACTION

 

 

NO RESPONSE

0

 

 

 

 

 

 

 

 

 

 

02

START EVENT

 

 

NOT USED

0

 

Enter the relay (output device) identification number 01-08. This is a reference number only, used for identification purposes. The actual module address and relay number on the module are programmed in the last two prompts.

Press [] to continue.

Press [] to continue.

The keypad displays a summary STOP screen.

Press [] to continue.

The Relay Action is the way in which the relay will respond when activated by the "start" event. Enter the desired action for this relay as follows:

0=not used; 1=close for 2 secs.; 2=stay closed; 3=pulse on/off

A relay may be activated by an Event/Zone List combination, and/or by a Zone Type/System Operation. For an Event/Zone List combination, enter the event code as follows:

0=not used; 1=alarm; 2=fault; 3=trouble

If you are not using a Zone List to activate the relay, enter 0. Press [] to continue.

 

02

START: ZN LIST

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

02

START: ZN TYPE

 

 

NO RESPONSE

00

 

A zone list is a set of zones that can be used to initiate the start or stop relay action. If a zone list is being used to start this relay action, enter the zone list number, 1-4. If a zone list is not being used, enter 0. Press [] to continue.

A Zone Type/System Operation can be used instead of or in addition to an Event/Zone List combination or a specific zone to start the relay action. If a Zone Type/System Operation is being used, enter the 2-digit code as listed in the table that follows.

Press [] to continue.

Choices for Start/Stop Zone Types and System Operations:

00

= No Response (Not Used)

 

23

= No Alarm Response

01

= Entry/Exit #1

31

= End of Exit Time

02

= Entry/exit #2

32

= Start of Entry Time

03

= Perimeter

33

= Any Burglary Alarm

04

= Interior Follower

34

= Code + [#] + 71 Key Entry

05

= Trouble Day/Alarm Night

35

= Code + [#] + 72 Key Entry

06

= 24-Hr. Silent

 

 

= At Bell Timeout **

36

07

= 24-Hr. Audible

37

= 2 Times Bell Timeout **

08

= 24-Hr. Auxiliary

38

= Chime

09

= Fire Alarm or Trouble

39

= Fire Alarm

10

= Interior w/Delay

40

= Bypassing

20

= Arming-STAY

31

= End of Exit Time

21

= Arming-AWAY

41

= AC Power Fail

22

= Disarming (Code + Off)

 

42

= System Battery Low

*Stop condition only

**Or at disarming, whichever occurs earlier

43 = Communication failure

44 = RF Low Battery

45 = Polling Loop Failure

51 = RF Receiver Failure

52 = Kissoff

54 = Fire Zone Reset

55 = Disarm + 1 Minute

56 = XX Minutes (enter XX in field 1*74) * 57 = YY Seconds (enter YY in field 1*75) * 58 = Duress

60 = Audio Alarm Verification (must be selected for both START and STOP operation)

If you are using options 56 and/or 57 (usually as the STOP Zone Type), you must program data fields 1*74 and 1*75 for the respective relay timeouts for minutes and seconds.

– 23 –

Image 23
Contents N7001PRV5 5/04 Rev a $0&29,67$Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form 59 *62 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 54 *57 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 2nd Page Fields Partition-Specific FieldsPartition # Program Fields 1st Page FieldsProgramming With #93 Menu Mode Zone Type PERIMETER03 Zone ProgrammingSET to CONFIRM? = YES Enter Zone no = QuitInput S/N Input TypeInput S/N AXXX-XXXX Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsSET to CONFIRM? Expert Mode Zone ProgrammingProgram field 200 Number of Partitions Enter Zone noFrom Template Input S/N XXX-XXXXZone Type Template Loop Function Wireless Key Default Templates 58045804BD Template Loop FunctionExit Edit MODE? Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Zone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingSelect the next word Select Default Screen modeSelect Custom Word Mode Accept the wordSave the word by pressing Type the word using one of two methods as followsFollow the same procedure as for custom words Enter the custom word number 01-20 you want to createAlpha Descriptor Vocabulary Character Ascii ChartVIP Module Device ProgrammingAlpha Keypad RF ExpanderTrouble AlarmFault Relay ProgrammingRelay Action No Response Start Event Not Used Relay Output Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Enter Relay #Unit Code Zone List ProgrammingStart Partn ANY Partition Relay Type Plex ECP Address Module RELAY# House CodeRelay Voice Descriptors Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationDescriptor Prim Partition # Char max Sub. # System Layout WorksheetsDefaults Access Codes & User Definitions for Partitions 1Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Input Types Zone Definitions for Keypad Panic Zones 95, 96Zone Definitions for System Zones 70, 88 89, 90, 91 Zone TypesChoices for System Operation are Relay Outputs WorksheetsPage Ground Ademco VISTA-40 Summary of ConnectionsEileen Way, Syosset, New York