Honeywell 2-Partitioned Security System, VISTA-40 Alpha Descriptors Programming, Exit Edit MODE?

Page 17

Alpha Descriptors Programming

You can program a user-friendly English language description/location for all protection zones, relays, keypad panics, polling loop short, and RF receiver supervision troubles.

Each description can be composed of a combination of words (up to 3) that are selected from a vocabulary of 244 words stored in memory, and any word can have an "s" or " ’s " added to it. In addition, up to 20 installer-defined words can be added to those already in memory. Thus, when an alarm or trouble occurs in a zone, an appropriate description for the location of that zone will be displayed at the keypad.

NOTE: Due to the use of 2-digit zone numbers, the first word of the descriptor is limited to 7 characters if you want it to fit on the top line of the display.

A custom installer’s message can be programmed for each partition, which is displayed when the system is "Ready" (e.g., THE PETERSONS’).

1.To program alpha descriptors, enter Programming mode, then press [#]93 to display "ZONE PROG?"

2.Press 0 (NO) twice to display "ALPHA PROG?".

3.Press 1 to enter Alpha Programming.

There are 5 submenu selections that will be displayed one at a time.

Press 1 to select the mode desired. Press 0 to display the next mode available. The alpha menu selections are:

ZONE DESCRIP?

DEFAULT SCREEN?

CUSTOM WORD?

PART DESCRIP?

For entering zone descriptors.

For creating custom message; displayed when system is ready.

For creating custom words for use in descriptors.

For creating 4-character partition names.

EXIT EDIT MODE?

Press 1 to exit back to #93 Menu Mode.

4.Refer to the sections that follow for procedures for adding alpha descriptors.

Zone Descriptors

1.Select ZONE DESCRIPTOR mode.

The keypad keys perform the following functions:

[3] Scrolls both alphabet and actual words in ascending alphabetical order.

[1]Scrolls both alphabet and actual words in descending alphabetical order.

[2]Adds or removes an "s" or " 's " to a vocabulary word.

[6] Switches between alphabet and actual word list; used to accept entries.

[8] Saves the zone description in the system's memory.

[#][#] plus zone number displays the description for that zone.

2.Enter the zone number to which you want to assign a descriptor.

For example, key [] 01 to begin entering the description for Zone 1, (key [] 02 for Zone 2, [] 03 for Zone 3, etc.). The following is displayed: ZN 01 A.

Note that the first letter of the alphabet appears after the zone number, and that the zone number is automatically included with the description.

3.Enter the descriptor for that zone. Use one of two methods as follows:

(Assume, for example, that the desired description for Zone 1 is BACK DOOR.)

a)Press [#] followed by the 3-digit number of the first word from the fixed dictionary shown later in this section (e.g., [0][1][3] for BACK).

Press 6 in order to accept the word and proceed, or press 8 to store the complete descriptor and exit; or

b)Select the first letter of the desired description (note that "A" is already displayed). Use the 3 key to advance through the alphabet and the 1 key to go backward.

Press 3 key repeatedly until "B" appears (press 1 to go backwards if you happen to pass it), then press 6 to display the first available word beginning with “B”.

Press 3 repeatedly to advance through the available words until the word “BACK” is displayed.

To add an "s" or " 's" if you need to, press 2. The first depression adds an "s," the second depression adds an " 's, " the third depression displays no character (erases the " 's"), the fourth depression adds an "s," etc.

– 17 –

Image 17
Contents N7001PRV5 5/04 Rev a $0&29,67$Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form OPEN/CLOSE Report for Keyswitch Enable OPEN/CLOSE Report for54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Partition # Program Fields Partition-Specific Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode SET to CONFIRM? = YES Zone ProgrammingEnter Zone no = Quit Zone Type PERIMETER03Input S/N Input TypeInput S/N AXXX-XXXX Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingEnter Zone no SET to CONFIRM?From Template Input S/N XXX-XXXX5804BD Wireless Key Default Templates 5804Template Loop Function Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Alpha Descriptors Programming Exit Edit MODE?Select Custom Word Mode Select Default Screen modeAccept the word Select the next wordFollow the same procedure as for custom words Type the word using one of two methods as followsEnter the custom word number 01-20 you want to create Save the word by pressingAlpha Descriptor Vocabulary Character Ascii ChartAlpha Keypad Device ProgrammingRF Expander VIP ModuleFault AlarmRelay Programming TroubleChoices for Start/Stop Zone Types and System Operations Relay Output Devices ProgrammingEnter Relay # Relay Action No Response Start Event Not UsedStart Partn ANY Partition Zone List ProgrammingRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationDescriptor Prim Partition # Char max Sub. # System Layout WorksheetsDefaults Access Codes & User Definitions for Partitions 1Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for System Zones 70, 88 89, 90, 91 Zone Definitions for Keypad Panic Zones 95, 96Zone Types Input TypesChoices for System Operation are Relay Outputs WorksheetsPage Ground Ademco VISTA-40 Summary of ConnectionsEileen Way, Syosset, New York