Honeywell VISTA-40 manual Zone Definitions for Keypad Panic Zones 95, 96, Zone Types, Input Types

Page 32

Zone

No.

95

96

99

ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 95, 96, & 99

Enter yes/no for each

partition (field *22)

Zone

 

 

Report

Zone Information (part numbers) &

Type

1

2

Code

Alpha Descriptor (3 words max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE DEFINITIONS FOR SYSTEM ZONES; 70, 88; 89, 90, 91 & 97

 

 

 

Zone Information (part numbers)

Zone

Zone

Report

&

No.

Type

Code

Alpha Descriptor (3 words max.)

70

88

89

90

91

97

00=zone not used 01=entry/exit 1 02=entry/exit 2 03=perimeter 04=interior (follower)

Zone Types:

05=day/night burglary 06=24-hour silent 07=24-hour audible 08=24-hour auxiliary 09=supervised fire

Input Types:

10=interior (w/delay) 20=arm stay 21=arm away 22=disarm

23=no alarm response

00=not used

05=RF button transmitter

01=hardwired

06=serial number polling loop

03=supervised RF transmitter

07=Dip switch-type polling loop

04=unsupervised RF transmitter

08=right loop dip switch polling loop

– 32 –

Image 32
Contents $0&29,67$ N7001PRV5 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form Enable OPEN/CLOSE Report for OPEN/CLOSE Report for Keyswitch54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Partition-Specific Fields Partition # Program Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode Zone Programming SET to CONFIRM? = YESEnter Zone no = Quit Zone Type PERIMETER03Input S/N Input TypeInput S/N AXXX-XXXX Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsEnter Zone no SET to CONFIRM?Input S/N XXX-XXXX From TemplateWireless Key Default Templates 5804 5804BDTemplate Loop Function Zone Type Template Loop FunctionZone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP? Zone Descriptors Select Zone Descriptor modeAlpha Descriptors Programming Exit Edit MODE?Select Default Screen mode Select Custom Word ModeAccept the word Select the next wordType the word using one of two methods as follows Follow the same procedure as for custom wordsEnter the custom word number 01-20 you want to create Save the word by pressingCharacter Ascii Chart Alpha Descriptor VocabularyDevice Programming Alpha KeypadRF Expander VIP ModuleAlarm FaultRelay Programming TroubleRelay Output Devices Programming Choices for Start/Stop Zone Types and System OperationsEnter Relay # Relay Action No Response Start Event Not UsedZone List Programming Start Partn ANY PartitionRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets Descriptor Prim Partition # Char max Sub. #Access Codes & User Definitions for Partitions 1 DefaultsZone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for Keypad Panic Zones 95, 96 Zone Definitions for System Zones 70, 88 89, 90, 91Zone Types Input TypesRelay Outputs Worksheets Choices for System Operation arePage Ademco VISTA-40 Summary of Connections GroundEileen Way, Syosset, New York