Honeywell 2-Partitioned Security System, VISTA-40 manual Series Transmitters Loop Designations

Page 13

5800 Series Transmitters Loop Designations

 

LOOP 3

 

 

 

 

LOOP 2

 

 

 

 

LOOP 1

 

 

 

 

 

 

 

LOOP

 

LOOP 4

 

 

1

 

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

5801

 

 

5 8 0 2 M N

ENROLL AS "UR" OR "RF"

ENROLL AS "UR" OR "RF"

YOU MUST

LOOP 3

 

 

 

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

LOOP 2

 

 

 

LOOP 4

 

 

 

LOOP 1

 

 

 

 

 

 

LOOP 2

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

 

LOOP 4

 

 

 

 

LOOP 1

5 8 0 4

LOOP 3

 

 

 

 

••

 

ENROLL

 

 

 

•••••

SET

 

 

• ••• •

AS "BR"

 

• •

HOUSE

 

 

 

 

 

CODE

 

 

5804BD

 

 

 

ENROLL AS "BR"

 

LOOP

 

 

 

 

1

 

 

 

5809

 

 

 

 

ENROLL AS "RF"

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(REED)

LOOP

 

 

 

 

1

 

 

LOOP 1

 

 

 

 

(TERMINALS)

5808

 

5 8 1 6

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

LOOP 2

 

LOOP 1

 

 

(REED)

 

 

 

 

(PRIMARY)

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(AUX. CENTER)

 

 

LOOP 1

 

 

 

 

(TERMINALS)

LOOP 3

 

 

 

 

ALTERNATE

 

 

 

(AUX. RIGHT)

POSITION

 

5 8 1 6 M N

 

5 8 1 7

FOR LOOP 2

 

 

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

 

 

LOOP 2

 

LOOP

 

 

(REED)

 

 

LOOP 1

 

 

2

 

 

 

 

(TERMINALS)

 

 

(REED)

 

 

 

 

 

 

 

 

 

 

 

LOOP 1

 

 

 

LOOP 3

(INTERNAL

 

 

(TERMINALS)

SHOCK

 

 

 

 

SENSOR)

LOOP 3

 

 

 

 

(TERMINALS)

 

 

 

 

 

5 8 1 9

 

5819S (WHS & BRS)

ENROLL AS "RF"

 

ENROLL AS "RF"

 

5 8 2 7

 

 

5 8 2 7 B D

SET HOUSE CODE

 

SET HOUSE CODE

LOOP 1 (MOTION)

(Green) (Red) (Yellow)

5850 (GBD)

5 8 9 0

ENROLL AS "RF"

ENROLL AS "RF"

5800_trans_loop-V0

Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.

 

 

UL

The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD,

 

 

and 5850 transmitters are not intended for use in UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROMPT

 

 

EXPLANATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XMIT TO CONFIRM PRESS TO SKIP

Entd A022-4063 1

Rcvd A022-4064

Confirmation Option: This prompt only appears if you answered “Yes” at the first prompt. The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [] key on the keypad to save the serial and loop number combination without confirming.

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it is also displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter or transmit the correct serial number.

10 ZT P RC In L

03 1 3C RF 1s

If the serial number transmitted does match the serial number entered, the system beeps 3 times and a summary display appears, showing that zone’s programming. Note that an “s” indicates that a transmitter’s serial number has been enrolled.

Press [] to accept the zone information.

– 13 –

Image 13
Contents N7001PRV5 5/04 Rev a $0&29,67$Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form OPEN/CLOSE Report for Keyswitch Enable OPEN/CLOSE Report for54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Partition # Program Fields Partition-Specific Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode SET to CONFIRM? = YES Zone ProgrammingEnter Zone no = Quit Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingEnter Zone no SET to CONFIRM?From Template Input S/N XXX-XXXX5804BD Wireless Key Default Templates 5804Template Loop Function Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Alpha Descriptors Programming Exit Edit MODE?Select Custom Word Mode Select Default Screen modeAccept the word Select the next wordFollow the same procedure as for custom words Type the word using one of two methods as followsEnter the custom word number 01-20 you want to create Save the word by pressingAlpha Descriptor Vocabulary Character Ascii ChartAlpha Keypad Device ProgrammingRF Expander VIP ModuleFault AlarmRelay Programming TroubleChoices for Start/Stop Zone Types and System Operations Relay Output Devices ProgrammingEnter Relay # Relay Action No Response Start Event Not UsedStart Partn ANY Partition Zone List ProgrammingRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationDescriptor Prim Partition # Char max Sub. # System Layout WorksheetsDefaults Access Codes & User Definitions for Partitions 1Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for System Zones 70, 88 89, 90, 91 Zone Definitions for Keypad Panic Zones 95, 96Zone Types Input TypesChoices for System Operation are Relay Outputs WorksheetsPage Ground Ademco VISTA-40 Summary of ConnectionsEileen Way, Syosset, New York