Honeywell VISTA-40 Wireless Key Default Templates 5804, 5804BD, Template Loop Function, Zone Type

Page 16

PROMPTEXPLANATION

PARTITION

1

ENTER ZONE NO

00 = QUIT

24

Example of zone number suggested by the system. This indicates that zones 24, 25, 26, and 27 are available.

24 INPUT S/N

L

AXXX-XXXX

1

 

 

XMIT TO CONFIRM

PRESS TO SKIP

Entd A022-4063

Rcvd A022-4064

Enter partition number for wireless key.

Press [] to continue.

The system searches for the highest available, consecutive 4-zone group (the four zones required for the 5804 and 5804BD), and displays the lowest zone number of the group.

If you want to start at a different zone number, enter the zone desired and press [].

If that zone number is displayed, the system has the required number of consecutive zones available, beginning with the zone you entered. If not, the system again displays a suggested zone that can be used.

If the required number of consecutive zones is not available at all, the system will display “00.” Press [] to accept.

To enter the serial number:

Press and release a button on the wireless key.

OR

Manually enter the 7-digit serial number printed on the device’s label. Press [] to accept serial number. The system checks for a duplicate.

If a duplicate exists, a long error beep will sound and the serial number reverts back to all “X”s allowing you to re-enter the serial number.

Use the [A] key to move forward within the screen, and the [B] key to back up.

If you entered YES previously at the SET TO CONFIRM prompt (see first prompt following entry into the Expert Programming Mode), the display on the left appears.

To confirm, activate the button on the wireless key that corresponds to this zone.

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key and then enter the correct serial number.

Activate the button on the wireless key again after re-entering the serial number.

ENTER ZONE NO

 

00 = QUIT

28

If the serial number transmitted matches the serial number entered, the system will beep 3 times and revert to the "Start Zone No." prompt and will show the lowest numbered zone of the next available 4-zone group (4 consecutive zones) that is available for programming.

After all the wireless keys have been entered, enter 00 for the zone number to quit.

After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device.

Wireless Key Default Templates

5804

Template 1

Template 2

Template 3

Loop Function

1No Response

2Disarming

3Arm AWAY

4No Response

Loop Function

1No Response

2Disarming

3Arm AWAY

4Arm STAY

Loop Function

124-Hour Panic

2Disarming

3Arm AWAY

4Arm STAY

 

5804BD

Zone Type

Template 4

23

 

22

 

21

 

23

 

Zone Type

Template 5

23

 

22

 

21

 

20

 

Zone Type

Template 6

07

 

22

 

21

20

Loop

1

2

3

4

Loop

1

2

3

4

Loop

1

2

3

4

Function

No Response

No Response

Arm AWAY

Disarming

Function

No Response

Arm STAY

Arm AWAY

Disarming

Function

24-Hour Panic

Arm STAY

Arm AWAY

Disarming

Zone Type

23

23

21

22

Zone Type

23

20

21

22

Zone Type

07

20

21

22

– 16 –

Image 16
Contents $0&29,67$ N7001PRV5 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form Enable OPEN/CLOSE Report for OPEN/CLOSE Report for Keyswitch54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Partition-Specific Fields Partition # Program Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode Zone Programming SET to CONFIRM? = YESEnter Zone no = Quit Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsEnter Zone no SET to CONFIRM?Input S/N XXX-XXXX From TemplateWireless Key Default Templates 5804 5804BDTemplate Loop Function Zone Type Template Loop FunctionZone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP? Zone Descriptors Select Zone Descriptor modeAlpha Descriptors Programming Exit Edit MODE?Select Default Screen mode Select Custom Word ModeAccept the word Select the next wordType the word using one of two methods as follows Follow the same procedure as for custom wordsEnter the custom word number 01-20 you want to create Save the word by pressingCharacter Ascii Chart Alpha Descriptor VocabularyDevice Programming Alpha KeypadRF Expander VIP ModuleAlarm FaultRelay Programming TroubleRelay Output Devices Programming Choices for Start/Stop Zone Types and System OperationsEnter Relay # Relay Action No Response Start Event Not UsedZone List Programming Start Partn ANY PartitionRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets Descriptor Prim Partition # Char max Sub. #Access Codes & User Definitions for Partitions 1 DefaultsZone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for Keypad Panic Zones 95, 96 Zone Definitions for System Zones 70, 88 89, 90, 91Zone Types Input TypesRelay Outputs Worksheets Choices for System Operation arePage Ademco VISTA-40 Summary of Connections GroundEileen Way, Syosset, New York