Honeywell VISTA-40 manual Expert Mode Zone Programming, Program field 200 Number of Partitions

Page 14

PROMPTEXPLANATION

ENTER ZONE NO.

 

00 = QUIT

11

The system now returns to the “ENTER ZONE NO.” prompt for the next zone. When all zones have been programmed, enter 00 to quit.

After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information (zone number, zone type, etc.) relevant to that device.

When you have finished programming all zones, test each using the system’s Test Mode. Do not use the Transmitter ID Sniffer Mode. The system checks only for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop, and also does not verify polling loop type zones.

Expert Mode Zone Programming

Expert mode allows you to program zones using the minimum number of screens and keystrokes. Enter the Programming mode with [Installer Code] + [8] [0] [0]

Before programming your zones, do the following:

1.Program field 200: Number of Partitions.

2.Enable your RF Receiver in Device Programming menu mode.

To program your zones, press 93 to display the "ZONE PROG?" prompt. Enter 0 (NO) to each prompt until the “EXPERT MODE?” prompt appears.

PROMPTEXPLANATION

 

EXPERT MODE?

 

 

1 = YES

0 = NO

0

 

 

 

 

 

 

 

 

SET TO CONFIRM?

 

 

0 = NO

1 = YES

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zn

ZT

P RC

In

L

 

01

03 1 10 HW

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zn

ZT

P

RC

In

L

 

10

03

1

10

RF

1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zn

ZT

P

RC

In

L

 

10

03

1

10

RF

-

 

Press 1 to enter Expert mode.

This prompt appears once upon entering Expert Mode.

If you select “Yes,” Confirmation prompts will be displayed after the device’s Serial and Loop numbers have been entered later.

A summary display appears, showing zone 1’s current programming or default values.

Enter the desired 2-digit zone number and press []. Note: If you want to exit the Expert mode, enter 00 + [].

If an “s” appears after the loop number, it indicates that the transmitter’s serial number has been enrolled. Use the [D] key to enter and duplicate wireless keys (see “Entering Wireless Keys” later)

Enter all zone information except for Loop number, or press [C] to copy the zone information on this screen from the last saved zone (including Loop).

ZT = Zone Type

P= Partition RC = Report Code

In = Input Device Type

L = Loop number to which the sensor is connected.

NOTE: Pressing the [C] copies the zone information from the last saved zone, which includes the input type. Verify this information is correct for this zone.

On this screen:

Use the [A] key to move to the right.

Use the [B] key to move to left and to back up to “ZT” field. Press [] to accept the existing or newly entered zone information.

– 14 –

Image 14
Contents $0&29,67$ N7001PRV5 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-40 Programming Form 54 *57 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 59 *62 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 1st Page Fields Partition-Specific FieldsPartition # Program Fields 2nd Page FieldsProgramming With #93 Menu Mode Enter Zone no = Quit Zone ProgrammingSET to CONFIRM? = YES Zone Type PERIMETER03Input S/N Input TypeInput S/N AXXX-XXXX Series Transmitters Loop Designations Xmit to Confirm Press to SkipEnter Zone no Expert Mode Zone ProgrammingProgram field 200 Number of Partitions SET to CONFIRM?Input S/N XXX-XXXX From TemplateTemplate Loop Function Wireless Key Default Templates 58045804BD Zone Type Template Loop FunctionAlpha Descriptors Programming Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Zone Descriptors Select Zone Descriptor mode Exit Edit MODE?Accept the word Select Default Screen modeSelect Custom Word Mode Select the next wordEnter the custom word number 01-20 you want to create Type the word using one of two methods as followsFollow the same procedure as for custom words Save the word by pressingCharacter Ascii Chart Alpha Descriptor VocabularyRF Expander Device ProgrammingAlpha Keypad VIP ModuleRelay Programming AlarmFault TroubleEnter Relay # Relay Output Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Relay Action No Response Start Event Not UsedRelay Type Plex ECP Address Module RELAY# House Code Zone List ProgrammingStart Partn ANY Partition Unit CodeRelay Voice Descriptors Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets Descriptor Prim Partition # Char max Sub. #Access Codes & User Definitions for Partitions 1 DefaultsZone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Types Zone Definitions for Keypad Panic Zones 95, 96Zone Definitions for System Zones 70, 88 89, 90, 91 Input TypesRelay Outputs Worksheets Choices for System Operation arePage Ademco VISTA-40 Summary of Connections GroundEileen Way, Syosset, New York